• Title/Summary/Keyword: colloid

Search Result 429, Processing Time 0.031 seconds

Fabrication of Colloid Thrusters using MEMS Technology

  • Park, Kun Joong;Song, Seung Jin;Sanchez, Manuel Martinez
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.588-592
    • /
    • 2004
  • This paper presents the preliminary fabrication results of colloid thrusters which can provide thrust of the order of micro to milli-Newtons. MEMS technology has been used for fabrication, and four essential fabrication techniques - deep etching with nested masks, isotropic plasma etching, anisotropic reactive ion etching, and direct fusion wafer bonding - have been newly developed. Among diverse models which have been designed and fabricated, the fabrication results of 4-inch wafer-based colloid thrusters are presented.

  • PDF

Preparation of ZnO Thin Film by Electrophoretic Deposition(EPD)

  • Jun, Byung-Sei
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.1
    • /
    • pp.78-83
    • /
    • 2012
  • The electrophoretic deposition(EPD) of ZnO nano-sized colloids is investigated by changing the colloid number concentration, applied force, and deposition time. The change of the colloid size in a suspension was examined by the different colloid number concentrations (N = $3.98{\times}10^{15}$, N = $3.98{\times}10^{14}$, and N = $3.98{\times}10^{13}$) with an increase of the deposition time and applied forces. Deposition behavior was investigated by changing the applied fields (from DC 5 V to 50 V) and the deposition time (5 min to 25 min). The surface microstructures of the as-deposited films were investigated by SEM. The dried films were sintered from $850^{\circ}C$ to $1,050^{\circ}C$ for 2 h and then the microstructures were also explored by SEM. The agglomeration rate was enhanced by increasing the colloid number concentration of colloids. Colloid number concentration in a suspension must be rapidly decreased at higher values of the electric field. ZnO nano-sized colloids had the highest zeta potential value of over -28 mV in methanol. A homogeneous microstructure was obtained at colloid number concentration of N = $3.98{\times}10^{13}$, applied DC field of 5 V/cm and 15 min of deposition time at an electrode distance of 1.5 cm. Under these conditions, the deposited films were sintered at $850^{\circ}C$ and $1,050^{\circ}C$ for 2 h. The results show a typical pore-free surface morphology of a uniform thickness of 400 nm under these experimental conditions.

Initial experience with intra-articular 188Re-tin colloid as a "radiation synovectomy" agent in various joints

  • Shinto, Ajit S;Indira, VU;Kamaleshwaran, KK;Banka, Vinay Kumar;Aswathy, KK;Thirumalaisamy, SG;Rajamani, V;Mallia, Madhav;Banerjee, Sharmila
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Radiation synovectomy has been proposed as a promising palliative therapy for recurrent joint effusions for the last two or three decades. Ionizing radiations emitted by intrarticularly administered radiolabelled colloids. The aim of this study was to assess the effectiveness of radiation synovectomy (RSV) using $^{188}Re$-tin colloid in the treatment of recurrent joint effusions and chronic synovitis of knee joints. Three phase bone scan was acquired for the concerned joint prior to radiosynovectomy. $^{188}Re$-tin colloid was prepared as per the reported protocol. 9 patients, diagnosed with rheumatoid arthritis and suffering from chronic resistant synovitis of the knee, ankle or elbow joints were administered the radiopharmaceuticals, checked for radiochemical purity >95% by intraarticular route. A whole body scan was acquired 2 h post-radiosynovectomy. In all the 9 treatments, no leakage to non-target organs was visible in the whole body scan. Static scans of the joint revealed complete retention of $^{188}Re$-tin colloid in the joints post administration of the agent. Clinically all patients exhibited a complete or partial response. RSV with $^{188}Re$-tin colloid was safe and effective in patients with chronic synovitis of rheumatoid origin.

A Prospective Clinical Study of Crystalloid and Colloid Solutions as Priming Additive Fluids for Cardiopulmonary bypass of the Small Children (소아에서 인공심폐기 충전액의 첨가용액으로서 사용한 crystalloid와 colloid 용액에 관한 임상연구)

  • Han, Jae-Jin;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.469-479
    • /
    • 1992
  • Searching for the clinical effects of colloid solutions that used to increasing the oncotic pressure of priming solutions at the cardiopulmonary bypass, 29 patients [who were diagnosised as simple VSD around 10kg of body weight and scheduled to be operated from June 1990 to December 1990 at Sejong General Hospital] were divided randomly and prospectively to the two groups: A group [15] was received 4gm% albumin as addition to the priming solutions and B Group [14] the same amount of Ringer`s lactated solution. 34 clinical parameters [Body weight, sex, age, body surface area, Qp/Qs, pulmonary arterial pressure, cardiopulmonary bypass time, anesthetic time, intraoperatively infused crystalloid and colloid amount, hemoglobin, hematocrit, serum sodium concentration, serum osmolarity, urine osmolarity, urine specific gravity, serum concentration, serum osmolarity, urine osmolarity, urine specific gravity, serum protein, serum albumin concentration, urine output, central venous pressure, postoperatively infused colloid amount, immedediate post-operative peak inspiratory pressure, cardiac index, blood pressure and pump flow during cardiopulmonary bypass, inotro-pic assist, diuretics, extubation period, total drain amount, duration of ICU] were measured and compaired between the two groups. There were no differences of preoperative and operative clinical parameters. And postoper-atively, practically there were no nearly differences at the clinical outcomes between the two groups, but some parameters [cardiac index, PIP, BP and pumpflow during CPB, etc] contributed to being preferable to the Group A at certain times [P<0.05]. Conclusively, it might be thought that the priming solution of cardiopulmonary bypass added by colloid solution had some beneficial effects on the patients, especially younger and associated with complex anomaly to be expected taken longer time of cardiopulmonary bypass, and more studies about the neonatal and complex anomaly cases were needed in that points.

  • PDF

Miniaturized Chromatographic Quality Control of $^{99m}Tc$ Radiopharmaceuticals (Miniaturized Chromatography에 의한 $^{99m}Tc$-표지 방사성의약품의 정도 관리)

  • Yeom, Mi-Kyoung;Jeong, Jae-Min;Jin, Kwang-Ho;Cho, Kyu-Jin;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.133-137
    • /
    • 1990
  • The general use of a number of $^{99m}Tc-labelled$ compounds makes the need for good routine quality control procedures, especially the labelling efficiency measurements. The purpose of these study were to measure the labelling efficiency of $^{99m}Tc-labelled$ MDP, DTPA, Tin colloid, and Antimony sulfide colloid using miniaturized paper and instant thin layer chromatography. The chromatographic systems include whatman 3 MM paper and acetone, Gelman ITLC-SG and 0.9% sodium chloride. The chromatographic strips are miniaturized $(1\times10\;cm)$, marked and numbered. Labelling efficiencies of $^{99m}Tc-labelled$ DTPA and Tin colloid were above 98.0%. $^{99m}Tc-labelled$ Antimony sulfide colloid was 90.0%. And labelling efficiency of $^{99m}Tc-labelled$ MDP was 89.0% Coefficient variance of $^{99m}Tc-labelled$ MDP, DTPA, Tin colloid, and Antimony sulfide colloid were 5.14%, 2.06%, 1.82% and 4.90%, respectively. We found that this miniaturized chromatographic quality control was simple and reliable.

  • PDF

A Study in Preparation of $^{113m}In$ colloid as Scanning Agent and it's Organ Distribution in Rats (주사용(走査用) $^{113m}In$ 교질(膠質)의 조제(調製) 및 흰쥐에서의 장기분포(臟器分布)에 관(關)한 연구(硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Hong, Chang-Gi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.73-82
    • /
    • 1969
  • The newly developed diagnostic method with application of $^{113}Sn-^{113m}In$ cow system ($^{113}Sn:\;T\frac{1}{2}$ 118 days, $^{113m}In:\;T\frac{1}{2}$ 1.7 hrs, 390 Kev, Single ${\gamma}$) has the remarkable advantages such as increased diagnostic ability by single large dose administration of $^{113m}In$ with no subsequent radiation hazard and shortened examining time. We reformed the research of following scope with the use of developed $^{113}Sn-^{113m}In$ cow (25 mCi) generator: The sizes of particles produced under various conditions were investigated, and possibility for application to the scannings of various organs such as brain, liver, lung, bone marrow and blood pool etc. were studied. Results: $^{113m}InCl_3$ solution eluted from diluted HCl solution (pH 1.5) passed through $^{113}Sn-^{113m}In$ generator, and there can be produced various sized particles of colloidal indium. And there observed the state of distribution of $^{113m}In$ in each organ which showed many differences according to the particle sizes of colloidal indium. The results are stated as follows: 1. The adjustment of pH is the most important factor in making the desirable particle size of colloidal indium. The colloid for blood pool showed the highest level as 7.1%/gm blood, at pH 1.7, the colloid of pH 3.5 for liver scanning showed the highest level, 88.4%, in the liver, the colloid pH 6 showed the highest level, 3.1%, in the spleen, and the colloid of pH 11.0 showed the highest level, 85.3%/gm, in the lung. 2. The colloid for liver scanning made with NaCl-NaOH system showed the highest liver uptake at pH 7.2, and at either higher or lower pH than 7.2 showed decrease of liver uptake more or less. 3. The activity of $^{113m}In$ eluted through $^{113}Sn-^{113m}In$ generator indicated over 90% in the initial 4 ml, and particularly 88.1%-86.0% in the initial 2 ml. 4. The incubation time, tempertaure and mechanical irritation related to colloid formation and coating of colloid were not the definite condition of influence.

  • PDF

Chemical Characteristics and Water Dispersible Colloid Content of Jeju Citrus Orchard Soils (제주도 감귤원 토양의 화학적 특성과 물 분산성 콜로이드 함량)

  • Oh, Sang-Sil;Chung, Jong-Bae;Hyun, Hae-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.130-135
    • /
    • 2002
  • Water-dispersible colloids are suspected to facilitate transport of contaminants to groundwater. This study evaluated some soil chemical properties in relation to the stability of colloids in soils of Jeju citrus orchards. Thirty surface soil samples were collected, and pH, organic matter content oxalate-extractable Al and Fe contents, and water-dispersible colloid content were measured. In soils of higher pH, water-dispersible colloid contents were higher. The stability of colloids was found to be significantly promoted at pH above 5$\sim$6. Since organic matter can act as a flocculant organic matter content significantly enhanced the colloid stability. In soils of less than 5% organic C, water-dispersible colloid content was expected to be significantly higher. In soils of higher oxalate-extractable Al and Fe contents, colloids remaining in suspension were lower. This indicated that amorphous oxides and hydroxides play important stabilizing roles in soil structure and can stabilize soil clay against dispersion. Therefore in soils of higher pH, lower organic matter, and lower amorphous clay minerals, the stability of water-dispersible colloids and the potential of colloid-mediated transport of organic chemicals to groundwater could be higher.