• 제목/요약/키워드: collector

Search Result 1,348, Processing Time 0.031 seconds

Research libraries as a scholarly communication system (학술정보 커뮤니케이션 시스팀으로서의 연구도서관)

  • 이영자
    • Journal of Korean Library and Information Science Society
    • /
    • v.9
    • /
    • pp.179-211
    • /
    • 1982
  • Many problems which today's research libraries are confronted with should be taken the measures to find some solutions in any ways. The purpose of this study is to identify the main stream of chaining of research libraries as an existing collector and distributor of scholarly information into a communication system adopting the concept of resource sharing and on-line bibliographic search as some possible ways for solutions. The conclusions of this study can be summarized as follows: 1) The research libraries will be imposed on more and more responsibilities to be a reservoir of the intellectual heritage of an individual, a nation and mankind. 2) The research libraries in the near future will have to develop their collections in the new environment of austerity with the limited budget. 3) It is more desirable for the future research libraries to have the attitude that they are in the business of information and communication rather than being an entity as "a library". 4) The resource sharing developed to solve the severe problems confrontal by research libraries will improve the organizational and technical mechanism for the access to the scholarly information. 5) The research libraries will produce more and more bibliographic database to expand the library materials which can be available and shared. 6) Though on-line search service will be sure to provide a considerable profit to the scholarly information users, it will take a long time for this service to be popularize because of the high ratio of service fee. 7) Two problems should be solved for the efficient service by on-line search. One is the continuous, updating training for the professional librarians. The other is that the common efforts for the quality control and standardization of data base by the data base producers should be made. 8) Taking all the items of the conclusions derived from the study of research libraries mainly in the United States into a consideration, the followings should be paid an attention. - The status-quo of the research libraries in Korea should be analyzed in very detailed and accurate way. - The problems of research libraries in Korea as the major scholarly communication system should be clarified based on the analysis. - The measures for the problems should be taken in the light of the unique characteristics of korean environment. - For the developing the most efficient measures, the formal organize action to lead and govern the long-aimed study on the problems of research libraries should be established and the government-level su n.0, pport for the legislation and finance should be provided for the realization of the result of the study.

  • PDF

Improving Haskell GC-Tuning Time Using Divide-and-Conquer (분할 정복법을 이용한 Haskell GC 조정 시간 개선)

  • An, Hyungjun;Kim, Hwamok;Liu, Xiao;Kim, Yeoneo;Byun, Sugwoo;Woo, Gyun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.9
    • /
    • pp.377-384
    • /
    • 2017
  • The performance improvement of a single core processor has reached its limit since the circuit density cannot be increased any longer due to overheating. Therefore, the multicore and manycore architectures have emerged as viable approaches and parallel programming becomes more important. Haskell, a purely functional language, is getting popular in this situation since it naturally supports parallel programming owing to its beneficial features including the implicit parallelism in evaluating expressions and the monadic tools supporting parallel constructs. However, the performance of Haskell parallel programs is strongly influenced by the performance of the run-time system including the garbage collector. Though a memory profiling tool namely GC-tune has been suggested, we need a more systematic way to use this tool. Since GC-tune finds the optimal memory size by executing the target program with all the different possible GC options, the GC-tuning time takes too long. This paper suggests a basic divide-and-conquer method to reduce the number of GC-tune executions by reducing the search area by one-quarter for every searching step. Applying this method to two parallel programs, a maximally independent set and a K-means programs, the memory tuning time is reduced by 7.78 times with accuracy 98% on average.

A New Strategy to Fabricate a Colloidal Array Templated $TiO_2$ Photoelectrode for Dye-sensitized Solar Cells

  • Lee, Hyeon-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.8.1-8.1
    • /
    • 2011
  • Nanocrystalline titanium dioxide ($TiO_2$) materials have been widely used as an electron collector in DSSC. This is required to have an extremely high porosity and surface area such that the dye can be sufficiently adsorbed and be electronically interconnected, resulting in the generation of a high photocurrent within cells. In particular, their geometrical structures and crystalline phase have been extensively investigated as important issues in improving its photovoltaic efficiency. In this study, we present a new strategy to fabricate a photoelectrode having a periodic structured $TiO_2$ film templated from 1D or 3D polystyrene (PS) microspheres array. Monodisperse PS spheres of various radiuses were used for colloidal array on FTO glasses and two types of photoelectrode structures with different $TiO_2$ materials were investigated respectively. One is the igloo-shaped electrode prepared by $TiO_2$ deposition by RF-sputtering onto 2D microsphere-templated substrates. At the interface between the film and substrate, there are voids formed by the decomposition of PS microspheres during the calcination step. These holes might be expected to play the predominant roles as scattering spherical voids to promote a light harvesting effect, a spacious structure for electrolytes with higher viscosity and effective paths for electron transfer. Additionally the nanocrystalline $TiO_2$ phase prepared by the RF-sputtering method was previously reported to improve the electron drift mobility within $TiO_2$ electrodes. This yields solar cells with a cell efficiency of 2.45% or more at AM 1.5 illumination, which is a very remarkable result, considering its $TiO_2$ electrode thickness (<2 ${\mu}m$). This study can be expanded to obtain higher cell efficiency by higher dye loading through the increase of surface area or multi-layered stacking. The other is the inverse opal photonic crystal electrode prepared by titania particles infusion within 3D colloidal arrays. To obtain the enlargement of ordered area and high quality of crystallinity, the synthesis of titania particles coated with a organic thin layer were applied instead of sol-gel process using the $TiO_2$ precursors. They were dispersed so well in most solvents without aggregates and infused successfully within colloidal array structures. This ordered mesoporous structure provides the large surface area leading to the enough adsorption of dye molecules and have an light harvesting effect due to the photonic band gap properties (back-and-forth reflection effects within structures). A major advantage of this colloidal array template method is that the pore size and its distribution within $TiO_2$ photoelectrodes are determined by those of latex beads, which can be controlled easily. These materials may have promising potentials for future applications of membrane, sensor and so on as well as solar cells.

  • PDF

Reefer Container Monitoring System using Trajectory Information (궤적 정보를 이용한 냉동 컨테이너 모니터링 시스템)

  • Lee, Myung-Jin;Lee, Eung-Jae;Ha, Deok-Cheon;Ryu, Keun-Ho;Baek, Seung-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.1
    • /
    • pp.23-39
    • /
    • 2005
  • As developing satellite communication, the tracking range of the moving objects which move in local area is expanded to the whole world. However previous logistics management system is able to monitor freight which transporting in local area using mobile communication system. In this paper, we propose the reefer container management system that manages the location information and other related information such as temperature, humidity of container using the satellite system. The proposed system consists of three parts; data collector, satellite communication manager, reefer container information manager. And the proposed system uses the moving object index for managing the trajectory of container and tracing the location of container or vessel that is transporting the container, and supports various services such as reefer container and vessel tracking, container control and container statistics to logistic companies like shipper and forwarding agent. And the system can be increasing the quality of container transportation service to the shipper, and it makes the efficient management of reefer container to the shipping company.

  • PDF

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

Effects of Conductive Material on $LiCoO_2$ Cathode for the Lithium ion Battery (리튬이온전지용 $LiCoO_2$ 정극의 도전재료에 따른 특성)

  • Coh Chil Hoon;Moon Seong In;Hyung Yoo Eup;Yun Mun Soo;Park Chun Jun;Yun Duk Hyun;Yun Suong Kyu
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.88-92
    • /
    • 1999
  • The apparent density. self-separation of the electrode composite from current collector in the electrolyte solution and specific resistance of electronic conduction of the electrode composite were examined by the variation of content of conductive material such as graphitic and black carbons in $LiCoO_2$ composite electrode for lithium ion battery. Increasing the content of conductive material, the apparent density of Lico02 composite electrode was decreased and that of $LiCoO_2$ in composite electrode was only rapidly decreased compared to that of composite. $LiCoO_2$ composite electrodes containing more than 4.1 weight percent of super s black as a conductive material were seU-separated by the immersion into 1 mol/I $LiPF_6$ in propylene carbonate and diethyl carbonate (1:1 volume ratio). Specific resistances related to the electronic conduction of composite electrode were decreased by the increasing the content i)f conductive material. Specific resistance of the composite electrode including $2\~3\%w/w$ of super s black as conductive material was similar to that of $12\%w/w$ of Lonza KS6. In the range of this study, super s black as conductive material is better than Lonza KS6 on battery capacity because of apparent density of $LiCoO_2$ in electrode composite including super s black is higher than that of Lonza KS6.

Numerical Modeling of Current Density and Water Behavior at a Designated Cross Section of the Gas Diffusion Layer in a Proton Exchange Membrane Fuel Cell (고분자전해질 연료전지의 동작압력에 대한 가스 확산층의 위치 별 전류밀도 및 수분거동에 대한 수치해석)

  • Kang, Sin-Jo;Kim, Young-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.161-170
    • /
    • 2012
  • There are many factors to consider when attempting to improve the efficiency of fuel cell operation, such as the operation temperature, humidity, stoichiometry, operation pressure, geometric features, etc. In this paper, the effects of the operation pressure were investigated to find the current density and water saturation behavior on a cross section designated by the design geometry. A two-dimensional geometric model was established with a gas channel that can provide $H_2$ to the anode and $O_2$ and water vapor to the cathode gas diffusion layer (GDL). The results from this numerical modeling revealed that higher operation pressures would produce a higher current density than lower ones, and the water saturation behavior was different at operation pressures of 2 atm and 3 atm in the cathode GDL. In particular, the water saturation ratios are higher directly below the collector than in other areas. In addition, this paper presents the dependence of the velocity behavior in the cathode on pressure changes, and the velocity fluctuations through the GDL are higher in the output area than in inlet area. This conclusion will be utilized to design more efficient fuel cell modeling of real fuel cell operation.

Study of Air-Breathing Polymer Electrolyte Membrane Fuel Cell Using Metal-Coated Polycarbonate as a Material for Bipolar Plates (도금된 폴리카보네이트 분리판을 이용한 공기 호흡형 고분자 전해질막 연료전지에 관한 연구)

  • Park, Taehyun;Lee, Yoon Ho;Chang, Ikwhang;Ji, Sanghoon;Paek, Jun Yeol;Cha, Suk Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.155-161
    • /
    • 2013
  • In this study, a metal-plated polycarbonate was adopted as a material for bipolar plates in a polymer electrolyte membrane fuel cell (PEMFC). The coated layers included 40-${\mu}m$-thick copper, 10-${\mu}m$-thick nickel, and 0.3-${\mu}m$-thick gold that respectively played the roles of current conduction, adhesion between copper and gold, and minimization of surface corrosion. The maximum power of the air-breathing PEMFC with polycarbonate bipolar plates was $120mW/cm^2$, which was similar to that of graphite bipolar plates. Finally, the maximum power of a 12-cell stack of polycarbonate bipolar plates was $132.7mW/cm^2$, and it had an operating time of 12 h. Therefore, this was considered a suitable material for bipolar plates in PEMFCs.

A novel TIGBT tructure with improved electrical characteristics (향상된 전기적 특성을 갖는 트렌치 게이트형 절연 게이트 바이폴라 트랜지스터에 관한 연구)

  • Koo, Yong-Seo;Son, Jung-Man
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.158-164
    • /
    • 2007
  • In this study, three types of a novel Trench IGBTs(Insulated Gate Bipolar Transistor) are proposed. The first structure has P-collector which is isolated by $SiO_2$ layer to enhance anode-injection-efficiency and enable the device to have a low on-state voltage drop(Von). And the second structure has convex P-base region between both gates. This structure may be effective to distributes electric-field crowded to gate edge. So this structure can have higher breakdown voltage(BV) than conventional trench-type IGBT(TIGBT). The process and device simulation results show improved on-state, breakdown and switching characteristics in each structure. The first one was presented lower on state voltage drop(2.1V) than that of conventional one(2.4V). Also, second structurehas higher breakdown voltage(1220V) and faster turn off time(9ns) than that of conventional structure. Finally, the last one of the proposed structure has combined the two structure (the first one and second one). This structure has superior electric characteristics than conventional structure about forward voltage drop and blocking capability, turnoff characteristics.

  • PDF

A Basic Study on Feasibility Analysis for Solar Energy Facility using Standard Broiler House Roof (표준육계사의 지붕을 활용한 태양에너지 설비 타당성 분석에 관한 기초 연구)

  • Kim, Jin-Hyun;Jung, Sung-Jin;Kim, Tae-Wook;Choi, Jun-Hak;Ha, Yu-Shin
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.57-65
    • /
    • 2014
  • In order to reduce greenhouse gas emissions in recent agricultural energy and increase the energy self-sufficiency rate of each farmer, it is extremely important to expand the supply of solar energy using unused space of agricultural facilities, roof. This study surveyed and analyzed the environmental and administrative factors such as problems according to the structure, azimuth and latitude of broiler houses and stability of standard broiler houses required to use broiler house roof based on the poultry houses in Sangju-si. The results can be summarized as follows: 55.6% of the solar energy facilities of according to the classification of arable lands of broiler houses were available, and 31.7% of them were available by classifying according to the azimuth. However, 20.6% of them were available in the survey considering all the arable land and azimuth. In the roof inclination of the broiler houses, from 20 to $25^{\circ}$ was the most common, 30 broiler houses. The broiler houses with the roof inclination more than $20^{\circ}$ accounted for 63% of the total. It was considered that the inclination was generally proper. In the structural safety, only 3 broiler houses that were constructed as a standard broiler house were available. In practice, all but one broiler house was inappropriate to expand the solar energy project using roof. The solar thermal facility weighed $63.6kg/m^2$ in total: the frame and solar thermal collector weighed $27.8kg/m^2$ and $35.8kg/m^2$, respectively. The standard broiler house required to be internally reinforced. This study suggested a plan for internal reinforcement and a feasible plan because there were problems with structural safety when installing solar thermal and photovoltaic systems.