• Title/Summary/Keyword: cold region engineering

Search Result 173, Processing Time 0.027 seconds

Experimental equipment for high efficiency heat pump development by CFD (CFD를 통한 고효율 히트펌프 개발을 위한 실험장치)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1402-1408
    • /
    • 2020
  • In order to save energy, a lot of research has been conducted to develop a high-efficiency heat pump. Research to reduce or eliminate the occurrence of frost in the outdoor unit coil is also being conducted at the same time. A constant temperature chamber was constructed that allows experimentation under the same conditions as in the natural state so that frost does not occur in the outdoor unit of the heat pump regardless of the season. In order to verify the validity of the experimental apparatus, a simulation was conducted by dividing the straight length of the duct in front of the outdoor unit in the constant temperature chamber, which is the experimental apparatus, into three conditions. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Overwintering Capacity Affected by Seeding Time and Method of Chinese Milk Vetch, Astragalus sinicus L., in Upland Field

  • Lee Ji Hyun;Kang Byeung Hoa;Shim Sang In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.2
    • /
    • pp.67-72
    • /
    • 2005
  • Overwintering capacity, closely related to winter hardiness, of Chinese milk vetch planted with different sowing times and sowing practices was investigated to improve the incorporation into cropping system in Korea. The tolerance to low temperature was evaluated with $LT_50$ using leaf disc leaching method. Dry weight of CMV was reduced remarkably with delayed planting from Sep. 5 to Oct. 20. The differences in tolerance to freezing temperature were not conspicuous among CMV genotypes, however, the differences between genotype (collections at different regions) were due to the plant architecture, mainly to the leaf angle. The crouching genotype collected at central region of Korean peninsula, which showed excellent freezing tolerant, has planophile leaves. The feature of internal constituents of CMV genotypes did not show any noticeable differences with respect to the freezing tolerance which evaluated by leaf disc leaching experiment. To overcome the poor overwintering capacity, tolerant genotype should be developed by selection with considering the plant architecture. The reduction of CMV growth during overwintering period was ameliorated with furrow-sowing under late-sown condition, therefore, when the CMV is inevitably sown late after recommended time, the seeds should be sown on furrow to overcome the cold stress.

DESIGN STUDY OF AN IHX SUPPORT STRUCTURE FOR A POOL-TYPE SODIUM-COOLED FAST REACTOR

  • Park, Chang-Gyu;Kim, Jong-Bum;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1323-1332
    • /
    • 2009
  • The IHX (Intermediate Heat eXchanger) for a pool-type SFR (Sodium-cooled Fast Reactor) system transfers heat from the primary high temperature sodium to the intermediate cold temperature sodium. The upper structure of the IHX is a coaxial structure designed to form a flow path for both the secondary high temperature and low temperature sodium. The coaxial structure of the IHX consists of a central downcomer and riser for the incoming and outgoing intermediate sodium, respectively. The IHX of a pool-type SFR is supported at the upper surface of the reactor head with an IHX support structure that connects the IHX riser cylinder to the reactor head. The reactor head is generally maintained at the low temperature regime, but the riser cylinder is exposed in the elevated temperature region. The resultant complicated temperature distribution of the co-axial structure including the IHX support structure may induce a severe thermal stress distribution. In this study, the structural feasibility of the current upper support structure concept is investigated through a preliminary stress analysis and an alternative design concept to accommodate the IHTS (Intermediate Heat Transport System) piping expansion loads and severe thermal stress is proposed. Through the structural analysis it is found that the alternative design concept is effective in reducing the thermal stress and acquiring structural integrity.

Characteristics of Front near the Cheju Strait in Early Winter (초겨울 제주해협 근해에서 형성되는 전선의 특성)

  • LEE Jae Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.2
    • /
    • pp.51-58
    • /
    • 1983
  • Off the southwest coast of Korea, changes in hydrographic fields from stratified state of summer to a vertically homogeneous one of winter appeared to occur most actively in November. During this transitional period coincident thermal and salinity fronts are formed along the boundary between the two water masses of cold coastal water with low salinity and of the Tsushima Current Water. Generally frontal zone lies where the bottom depth is about 70-90m except for the central region of the Cheju Strait in which the influence of the Tsushima Current is weak. Result of the drift bottle experiment in November 1930 supports the existence of the westward coastal current.

  • PDF

Deformation Characteristics of Compound Curved Plate Bending by Asymmetric Rollers (상하 비대칭 롤러를 이용한 이중곡면 성형의 변형특성에 대한 연구)

  • 최양렬;신종계
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.38-43
    • /
    • 2002
  • Die-less forming is a cold forming process which is to bend thick flat plates into compound curved plates using two asymmetric rollers. This forming method has several advantages compared with line heating which is widely used to fabricate compound curved pieces in shipyards. The die-less forming, however, has scarcely been studied. Even the deformation mechanism in this forming process has not been understood clearly. So, in this paper, the deformation characteristics of die-less forming is investigated analytically and numerically. for the analytic investigation, slab method based on equilibrium equation is applied. And the mechanism of curvature generation is derived for the asymmetry in roller applied. And three dimensional numerical analyses are performed with realistic modeling of interactions between the rollers and work-piece using finite element program, ABAQUS. It is shown that curvature generation is mainly due to the difference of normal positive strain distribution between the top and bottom surface of the work-piece. And a convex-type curved plate is formed if the center region of the work-piece is rolled with asymmetric rollers of which the lower is larger than the upper in diameter.

On the validation of ATHLET 3-D features for the simulation of multidimensional flows in horizontal geometries under single-phase subcooled conditions

  • Diaz-Pescador, E.;Schafer, F.;Kliem, S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3567-3579
    • /
    • 2022
  • This paper provides an assessment of fluid transport and mixing processes inside the primary circuit of the test facility ROCOM through the numerical simulation of Test 2.1 with the system code ATHLET. The experiment represents an asymmetric injection of cold and non-borated water into the reactor coolant system (RCS) of a pressurized water reactor (PWR) to restore core cooling, an emergency procedure which may subsequently trigger a core re-criticality. The injection takes place at low velocity under single-phase subcooled conditions and presents a major challenge for the simulation in lumped parameter codes, due to multidimensional effects in horizontal piping and vessel arising from density gradients and gravity forces. Aiming at further validating ATHLET 3-D capabilities against horizontal geometries, the experiment conditions are applied to a ROCOM model, which includes a newly developed horizontal pipe object to enhance code prediction inside coolant loops. The obtained results show code strong simulation capabilities to represent multidimensional flows. Enhanced prediction is observed at the vessel inlet compared to traditional 1-D approach, whereas mixing overprediction from the descending denser plume is observed at the upper-half downcomer region, which leads to eventual deviations at the core inlet.

Estimating carbon dioxide uptake in wetland ecosystems of Tumen River Basin using eddy covariance flux data (에디 공분산 기반의 플럭스 타워 관측자료를 이용한 두만강 유역 습지 생태계 CO2 흡수량 분석)

  • Chen, Pengshen;Zhao, Shuqing;Cui, Guishan;Lee, Dongkun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.27 no.3
    • /
    • pp.67-74
    • /
    • 2024
  • In the context of rapid temperature rise in mid-to-high latitude regions, cold region wetlands have become a hotspot for current wetland carbon cycle research due to their high sensitivity to climate change. Strengthening the monitoring of CO2 fluxes in wetland ecosystems is of great practical significance for clarifying the carbon balance of wetlands and maintaining the ecological balance of wetland ecosystems in China's high latitude regions. In this study, the carbon flux (NEE, Net ecosystem exchange; GPP, Gross Primary Production; RECO, Ecosystem response) of Jingxin Wetland was monitored by eddy correlation method from August 2021 to March 2024.2022-2023 shows CO2 sinks, absorbing 349.4 g C·m-2·yr-1 annually. The correlation analysis showed that Ta, VPD and PPFD were the main environmental factors affecting CO2 flux in Jingxin wetland.

A Study on the Cold Flow Characteristics of a Flue Gas Recirculation Burner with Both Outlets Opening (양쪽 출구가 트인 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.7-12
    • /
    • 2018
  • Thermal NOx is generated in a high temperature environment in a combustion facilities. Exhaust gas recirculation method is widely used among various methods for reducing nitrogen oxides in combustion devices. In the present study, the computational fluid dynamic analysis was accomplished to elucidate the cold flow characteristics in the flue gas recirculation burner with both outlets opening. Because the reciculation pipes is installed toward the tangential direction, the swirling flow is formulated in the burner and the phenomenon of the reverse flow creation is detected at the center area of circular burner. We are confirmed that this is the similar trend with the burner with one side outlet closed. From the present study, it was seen that the recirculated inflow from both recirculated burner outlets increased by about 5% compared to the burner with one side outlet opening. At the outlet located at the exhaust gas recirculation pipe inlet(gas exit 1), the inlet flow was formed in the entire region. At the opposite outlet(gas exit 2), the total flow was discharged, but the center part of the burner was observed to have a reverse flow. The flow rate at the gas exit 2 was 3 ~ 5 times larger than the flow rate at the gas exit 1.

Experimental Study on the Cooling and Heating Characteristics of System A/C Applying the Digital Scroll Compressor (디지털 스크롤 압축기를 적용한 시스템 에어컨의 냉난방특성에 대한 실험적 연구)

  • Jeon, Yong-Ho;Kim, Dae-Hoon;Kwon, Young-Chul;Jang, Geun-Sun;Lee, Yoon-Soo;Moon, Je-Nyung;Yoon, Baek;Hong, Ju-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.454-460
    • /
    • 2003
  • In order to investigate the cooling and heating characteristics of a variable-capacity system A/C applying a digital scroll compressor, the cooling and heating capacities and COP are measured by the psychrometric calorimeter. The capacity of the system is controlled by the digital scroll compressor, which is operated by controling PWM valve and the loading vs. unloading time. In the case of unloading compared that of loading, the consumption power of the compressor is about 11% and the capacity variation of the system A/C is within about 1%. When the system A/C is operated under the cooling and heating standard conditions, COP is nearly uniform but cooling capacity and heating capacity increase at minimum, rated and maximum modes. The system A/C applying the digital scroll compressor is effective for the range with high load or the width of large load variation. When the auxiliary heater is on, at the cold region, the system A/C produces the excellent heating capacity.

Empirical Orthogonal Function Analysis on the Monthly Variation of Flow Pattern in the East Sea of Kore (경험적 고유함수법에 의한 한국동해 해황변동해석)

  • CHANG Sun-Duck;LEE Jong-Sup;SUH Jong-Moon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.6
    • /
    • pp.323-330
    • /
    • 1988
  • The spatial distribution of sea water temperature variation pattern in the South-eastern coastal region of Korea was studied by empirical orthogonal function (E. O. F) analysis in several depths from surface to 300m using the monthly mean water temperature averaged for 23 years, water mass analysis by T. S diagram and sectional diagram of water temperature. Typical type of water temperature variation in this area can be divided into surface (0m-50m), subsurface (100m-150m) and intermediate (200m-300m) layer. The first mode value of water temperature change on the surface layer showed $99\%$ of total variation, and decreased with the increase of the depth. It is deduced to be in the range of $60-70\%$ on the 300m layer. The representative type of water temperature fluctuation by the first mode in each layer is as follows. Water temperature change in the surface layer showed a seasonal variation. In the subsurface layer, it is governed by the interaction of the Tsushima Warm Current water with the cold water and by the heat transfer process from the upper layer. In the intermediate layer, water temperature variation seems to be governed by the advection of the bottom cold water.

  • PDF