• 제목/요약/키워드: cold plate

검색결과 344건 처리시간 0.027초

냉동 냉면류의 제조공정별 미생물학적 위해요소 평가 (Microbial Hazard Analysis of the Manufacturing Processes for Frozen Korean Cold Noodle, Naengmyeon)

  • 김유정;김혜진;임영은;양혜걸;박슬기;정진숙;엄애선
    • 급식외식위생학회지
    • /
    • 제3권1호
    • /
    • pp.38-44
    • /
    • 2022
  • This study investigated the microbiological hazards in the manufacturing processes of Naengmyeon. Sanitary indicative bacteria, such as aerobic plate counts and coliforms as well as pathogenic bacteria, were examined from raw materials, manufacturing processes, working area, 17 utensils and equipment. The aerobic plate counts for raw materials and arrowroot starch estimated as 0.77±0.68~5.02±0.28 and 5.02±0.28 log CFU/g, respectively. Coliforms were detected from wheat flour, buckwheat flour, and potato starch. Staphylococcus aureus was detected to be 0.61±1.06 log CFU/g in wheat flour and 0.20±0.35 log CFU/g in buckwheat flour. During the manufacturing process, aerobic plate counts for kneading process were 4.54±0.34 log CFU/g. But after the press out and heat process, contamination of aerobic plate counts and coliforms decreased and remained at a low level until the release process. Aerobic plate counts before washing disinfection of screw were 3.28±0.62 log CFU/100 cm2, the level of which was high in utensils and equipment that had contact with employees or water. These results represent not only an important indicator for the hygienic level but also a scientific basis for analyzing biological hazards, which lead to the introduction of HACCP for the production of safe and hygienic cold noodles processed by manufacturers.

Column design of cold-formed stainless steel slender circular hollow sections

  • Young, Ben;Ellobody, Ehab
    • Steel and Composite Structures
    • /
    • 제6권4호
    • /
    • pp.285-302
    • /
    • 2006
  • This paper describes the design and behaviour of cold-formed stainless steel slender circular hollow section columns. The columns were compressed between fixed ends at different column lengths. The investigation focused on large diameter-to-plate thickness (D/t) ratio ranged from 100 to 200. An accurate finite element model has been developed. The initial local and overall geometric imperfections have been included in the finite element model. The material nonlinearity of the cold-formed stainless steel sections was incorporated in the model. The column strengths, load-shortening curves as well as failure modes were predicted using the finite element model. The nonlinear finite element model was verified against test results. An extensive parametric study was carried out to study the effects of cross-section geometries on the strength and behaviour of stainless steel slender circular hollow section columns with large D/t ratio. The column strengths predicted from the parametric study were compared with the design strengths calculated using the American Specification, Australian/New Zealand Standard and European Code for cold-formed stainless steel structures. It is shown that the design strengths obtained using the Australian/New Zealand and European specifications are generally unconservative for the cold-formed stainless steel slender circular hollow section columns, while the American Specification is generally quite conservative. Therefore, design equation was proposed in this study.

인코넬 718합금 선재의 냉간 인발시 δ 상 저온 석출 현상 연구 (Low Temperature δ-Precipitation of Inconel 718 Alloy Wire during Cold Drawing)

  • 박재만;김용환;장휘운;정원섭
    • 대한금속재료학회지
    • /
    • 제50권7호
    • /
    • pp.511-516
    • /
    • 2012
  • Low temperature ${\delta}$-precipitation phenomenon below 2-step aging ($718^{\circ}C$, $8hr+621^{\circ}C$, 8 hr) temperature of cold drawn Inconel 718 alloy wire was investigated. The investigation was carried out on wires with a cold drawn ratio of 0, 20, 50 and 70% using OM, SEM, XRD, TEM, and DSC. In microstructures of 50 and 70% drawn wire, many precipitates were found along the grain boundaries and the twin boundaries in deformation band. From the results of the XRD and TEM analysis, the precipitates were identified as plate-like ${\delta}$-phase. From the results of the DSC analysis, it was also found that a temperature of ${\delta}$-precipitation decreases with an increase of the cold drawn ratio. We concluded that cold drawing of inconel 718 wire promotes the ${\delta}$-precipitation, and under the condition of a high drawing ratio, the ${\delta}$-phase could be precipitated at a temperature below the aging temperature ($718^{\circ}C$).

단상유동 조건에서 용접형 판형 열교환기의 열전달 및 압력강하 특성연구 (Heat Transfer and Pressure Drop Characteristics of Brazed Plate Heat Exchangers with Single-Phase Flow)

  • 김만배;박창용
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.522-528
    • /
    • 2014
  • This experimental study measured and analyzed the heat transfer and pressure drop performance of brazed plate heat exchangers. Heat exchangers with different plate numbers of 10, 20, 30, and 40 were used for measurement, and their plate pattern was identical. The experiment was performed with distilled water, by changing the hot-side flow rate, with the cold-side flow rate fixed. The experimental results were compared with the calculated values by correlations based on gasketed plate heat exchangers, and showed that the heat transfer performance and pressure drop of brazed plated heat exchangers were higher than those of gasketed plate heat exchangers. From the variation of the friction factor, it could be inferred that in the flow channels of brazed plate heat exchangers, turbulent flow occurred at Reynolds numbers higher than 500. A new correlation to predict the Nusselt number was developed, and its absolute average deviation was 2.62%, compared with the values from the experimental data.

신경병증성통증 모델쥐에서 냉자극 유발 통증의 교감신경성 의존도 (Sympathetic Dependency of Cold-evoked Pain Behavior Seen in Rats with Peripheral Neuropathy)

  • 최병옥;최윤;곽영섭;남택상;백광세;임중우
    • The Korean Journal of Pain
    • /
    • 제13권2호
    • /
    • pp.156-163
    • /
    • 2000
  • Background: Peripheral nerve injury sometimes leads to chronic neuropathic pain such as causalgia. A subset of patients with causalgia have a sympathetically maintained pain which is often evoked by cooling stimuli. However, our knowledge on adrenergic receptor types responsible for cold-evoked pain that is sympathetically dependent is lacking. The present study was conducted to investigate subtypes of adrenoceptors involved in mediating cold-evoked pain that developed following peripheral nerve injury. Methods: Neuropathic surgery was performed by a unilateral ligation of L5 and L6 spinal nerves of rats. Behavioral sign of cold-evoked pain was examined for 5 min by measuring cumulative duration of time that the rat lifted its foot off a metal plate held at cold temperature ($5^{\circ}C$). Whether cold-evoked pain behavior was affected by antagonists of various subtypes of adrenoceptors, which were administered intraperitoneally before and after the ligation, was investigated. Results: After ligation, duration of foot lifting on the ligated side at cold temperature increased as compared to the pre-operative period. This increase maintained for the entire 40-day test period. Pretreatment with alpha-antagonist phentolamine produced a suppression of cold-evoked pain behavior that was not affected by beta-antagonist propranolol pretreatment. Prazosin, alpha-1 antagonist, suppressed cold- evoked pain behavior when treated either before or after nerve ligation. On the other hand, alpha-2 antagonist yohimbine was without effect on cold-evoked pain behavior whether it was treated before or after the ligation. Conclusions: The results suggest that peripheral nerve injury develops cold-evoked pain that is sympathetically dependent, and that alpha-1 adrenoreceptor plays a critical role for the generation of this type of pain in its initiation as well as maintenance.

  • PDF

편의점에서 판매되는 햄버거와 샌드위치의 유통과정중 품질관리에 관한 연구 (A Study on the Quality Control for the Circulation Steps including Productipn, Transportation, Selling about Hamburger & Sandwich in Convenience Store)

  • 김혜영;송용혜
    • 한국식생활문화학회지
    • /
    • 제11권4호
    • /
    • pp.465-473
    • /
    • 1996
  • The purpose of this study was to evaluate microbiological hazards in the steps of production, transportation and selling of hamburger and sandwich that were marketed in CVS, then to identify methods of control. The reasults are as follows: As the reasult of operation surroundings of manufacturerand reserch of circulation, $4{\sim}6$ hours are needed from manufacturer to CVS. Also transportation car mean temperature was $10^{\circ}C$ which exceeds the standard of $7^{\circ}C$ or below. Hamburger: Critical control points identified were purchasing, cooking, post-preparation, transportation and holding at CVS. As the reasult of microbial analysis following the case of holding methods and reheating at CVS, microbes of cold holding and reheat after cold holding was within standard value. But in the case of room temperature microbes exceeded standard value. Sandwich: Critical control points identified were purchasing, cooking, post-preparation, transportation and holding at CVS. As the reasult of microbial analysis following the case of holding methods and reheating at CVS, total plate counts of cold holding and reheat after cold holding was within standard value. But in the case of room temperature holding after 24 hours total plate counts exceeded standard value. In the case of room temperature holding the number of microbes increased according to the passage of time. As a reasult of food poisoning bacteria, it was negative in every test in sample against V. parahaemolyticus, Salmonella, S. aureus.

  • PDF

판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가 (Experimental measurements of R-22 two-phase friction factor in plate heat exchangers)

  • 유상훈;정지환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

딤플형 판형 열교환기의 열유동 수치해석 (A Numerical Analysis of Flow and Heat Transfer in the Plate Heat Exchanger with Dimple)

  • 안혁진;이상혁;이명성;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.121-125
    • /
    • 2008
  • In this study, the characteristics of internal flow and the heat transfer performance of dimpled plate heat exchanger were numerically investigated. For the numerical analysis, conjugate heat transfer method between cold fluid - plate - hot fluid was studied with appropriate boundary conditions. Velocity magnitude, temperature and pressure distribution were obtained from the simulation. Correlations for fanning f-factor and Colburn j-factor were obtained from numerical results and compared to the experimented data.

  • PDF

화력발전용 가스재열기 Sector Plate의 유한요소 해석 (Finite Element Analysis of Gas-Gas Heater Sector Plate in Thermal Power Plant)

  • 황석환;이후광;최재승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.860-864
    • /
    • 2001
  • Today's industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization (FGD) system is installed and gas-gas heater (GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design.

  • PDF

High Strength Low Alloy Steel for Sour Service

  • Jung, Hwan Gyo;Kim, Sang Hyun;Yang, Boo Young;Kang, Ki Bong
    • Corrosion Science and Technology
    • /
    • 제7권5호
    • /
    • pp.288-295
    • /
    • 2008
  • The increase use of natural gas as an energy source has been continuous demand for ever-increasing strength in gas transmission pipeline materials in order to achieve safe and economic transportation of natural gas. In particular, linepipe material for sour gas service primarily needs to have crack resistant property. However, applications of sour linepipes are expanding toward deep water or cold region, which require higher toughness and/or heavier wall thickness as well as higher strength. To improve the crack resistance of linepipe steel in sour environment, low alloy steel are produced by controlled rolling subsequently followed by the accelerated cooling process. This paper summarizes the design concepts for controlling crack resistant property low alloy linepipe steels for sour gas service.