• Title/Summary/Keyword: cold plate

Search Result 344, Processing Time 0.025 seconds

하향유동 영역에서 경사 등온평면에 의하여 야기된 정상상태 자연대류의 다중해 (Multiple Solutions for Steady State Natural Convection adjacent to an Inclined Isothermal Flat Plate in the Region of Largely Downflow)

  • 유갑종;이택식;조승환
    • 대한기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.1011-1020
    • /
    • 1991
  • 본 연구에서는 하향유동영역에서 수직면으로부터 경사각이 60˚ 이하인 경사 등온면이 저온의 물속에 잠겨 있을때 일어나는 다중정상상태 영역을 밝혀내고, 이 영 역에서 경사각이 열전달, 온도분포, 속도분포, 부력분포 및 누셀트 수에 미치는 영향 을 구명하였다. 또 해석방법은 이제까지 발표된 연구결과와 비교검토하기 위하여 기 존 논문에서와 같이 상이해석을 사용하였다.

On the structural behavior of ship's shell structures due to impact loading

  • Lim, Hyung Kyun;Lee, Joo-Sung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권1호
    • /
    • pp.103-118
    • /
    • 2018
  • When collision accident between ships or between ship and offshore platform occurs, a common phenomenon that occurs in structures is the plastic deformation accompanied by a large strain such as fracture. In this study, for the rational design against accidental limit state, the plastic material constants of steel plate which is heated by line heating and steel plate formed by cold bending procedure have been defined through the numerical simulation for the high speed tension test. The usefulness of the material constants included in Cowper-Symonds model and Johnson-Cook model and the assumption that strain rate can be neglected when strain rate is less than the intermediate speed are verified through free drop test as well as comparing with numerical results in several references. This paper ends with describing the future study.

New record of the cold freshwater dinoflagellate Palatinus apiculatus (Dinophyceae) from the Paldang Reservoir, Korea

  • Kim, Taehee;Ki, Jang-Seu
    • Journal of Species Research
    • /
    • 제11권3호
    • /
    • pp.162-168
    • /
    • 2022
  • Compared to marine dinoflagellates, freshwater species are rarely recorded in Korea. In the present study, we isolated a freshwater dinoflagellate, Palatinus, from the Paldang Reservoir, Korea, in December 2021. The overall cell shape was ovoid, and the cell size was 34.3 ㎛ in length (25.8-39.5 ㎛) and 28.4 ㎛ in width (21.5-34 ㎛). An eyespot was usually observed near the sulcal region. The Kofoidian plate formula of the species was determined to be 4', 2a, 7", 6c, 5s, 5''', and 2''''. Apical pore complex was not observed. However, variations in the cingular plate caused by the fusion of 3C and 4C were observed. Analyses of 28S rDNA sequences revealed that the unidentified species is 100% similar to Palatinus apiculatus, and clustered together in the same lineage in the phylogenetic tree (100% bootstrap value). Our findings confirmed that the isolated dinoflagellate is Palatinus apiculatus, which was discovered for the first time in Korean freshwaters.

스컬(Skull)법에 의한 Y-Ba-Cu-O계 단결정 성장 (Y-Ba-Cu-O Single Crystals Growth by Skull Method)

  • 정대식;오근호
    • 한국세라믹학회지
    • /
    • 제27권1호
    • /
    • pp.43-47
    • /
    • 1990
  • An attempt was made to grow Y-Ba-Cu-O single crystals by skull method(cold crucible process). Grown YBa2Cu3O7-x(YBC) single crystals were obtained from the upper part of the YBC solid mixture. There were plate-like YBC single crystals aligned with solidified flux along the crystal growth direction. Single crystal size was (5$\times$2$\times$0.2㎣) and was grown to a-b plane of YBC crystal structure which can flow super currents. Optical microscope and X-ray diffraction were employed characterize these microstructure and YBC single crystals.

  • PDF

유냉각기의 열전달 촉진에 관한 연구 (A Study on Heat Transfer Enhancement of Oil Cooler)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.25-30
    • /
    • 2011
  • A shell-and-tube oil cooler with plate fins was suggested to improve the defect of the conventional shell-and-tube oil cooler. Experiments were conducted to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube oil cooler with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. From the experiment of shell-and-tube oil cooler, it was found that the heat transfer coefficient of oil cooler with 9 tubes, as oil flow rate was increased, was approximately 140% and 250% higher than that of 13 and 19 tubes, respectively. The heat transfer coefficient at the water flow rate of $3m^3/h$, also was 120% and 140% higher than that of 2.4 and $1.8m^3/h$, respectively.

판각형 열교환기내의 R-134a 응축열전달 특성에 관한 실험적 연구 (Experimental Study on R-l34a Condensation Beat Transfer Characteristics in Plate and Shell Heat Exchanger)

  • 이기백;박재홍;서무교;이희웅;김영수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권1호
    • /
    • pp.108-116
    • /
    • 2003
  • In this paper, the experimental results of condensation heat transfer were reported for the plate and shell heat exchangers(P&SHE) using R-l34a. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-l34a in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by three plates of geometry with a corrugated trapezoid shape of a chevron angle of 45$^{\circ}$. Downflow of the condensing R-l34a in one channel releases heat to the cold up flow of water in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality of R-l34a on the measured data were explored in detail. The results indicate that at a higher vapor quality the condensation heat transfer coefficients are significantly higher. Condensation heat transfer coefficients were increased when the refrigerant mass flux was increased. A rise in the average heat flux causes an slight increase in the hr. Finally, at a higher system pressure the hr is found to be lower. Correlation is also provided for the measured heat transfer coefficients in terms of the Nusselt number.

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅱ) - 전열판의 회전수 변환에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.18-23
    • /
    • 2005
  • The experimental investigation was carried out to evaluate the performance of air-to-air heat exchanger with rotating porous plates newly developed in this study. The rotating porous plates are mounted with an equal interval of 18 mm inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. The material of the porous plate is cooper and its thickness is 1.0 mm. Air flow rate is varied from 10 to 120 m3/h. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat exchange performance increased with the increase in RPM of the porous rotating discs at the conditions of the same air flow rate. The sensible heat exchange efficiency was maximum 60 to 70 percent, and enthalpy exchange efficiency 50 to 60 percent.

  • PDF

고온 열판에 충돌하는 액적의 거동에 대한 유동가시화 연구 (A Visualization Study on the Characteristics of Droplets Impinging on a Hot Surface)

  • 김동연;이승재;김경천
    • 한국가시화정보학회지
    • /
    • 제10권1호
    • /
    • pp.21-26
    • /
    • 2012
  • Hydrophobic characteristics of high temperature metal surface were investigated by high-speed visualization of water droplet impact. An aluminum plate was used as the sample plate and the initial diameter of a water droplet was 2 mm. Transient behavior of a single droplet impinging on the surface with and without heating was captured by using a high speed camera running at 4,000 frames per second. The Leidenfrost phenomenon was demonstrated for the case of $300^{\circ}C$ surface temperature, however there was no rebounding of droplet on the cold plate due to hydrophilic nature. The experimental results show that the shape evolution of a droplet impinging on the surface varies with the Weber number, i.e. the ratio of impact inertia to capillary force. The overall water-repellent characteristics of the heated surface was very similar to that of the super hydrophobic surfaces.

화력발전용 가스재열기의 응력 해석 (Stress Analysis of Gas-Gas Heater in Thermal Power Plant)

  • 황석환;최재승;이후광
    • 한국정밀공학회지
    • /
    • 제19권1호
    • /
    • pp.204-211
    • /
    • 2002
  • Today\`s industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization(FGD) system is installed in thermal power plant and gas-gas heater(GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas-gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design. And finite element analysis(FEA) for rotor part in GGH is performed with original model and two weight-reduced models with different diaphragm thickness, respectively. Stress concentrations at rotor diaphragm happen due to the dead weight, pressure difference between treated and untreated gas, and thermal distribution in the rotor. As the thickness of diaphragm is decreased, the stress level is increased. The direction of treated gas and untreated gas flow may affect the stress level.