• Title/Summary/Keyword: cold air sink

Search Result 25, Processing Time 0.033 seconds

Analysis of the Damaged Range Caused by LPG Leakage and Vapor Clouds Considering the Cold Air Flow (찬공기 흐름을 고려한 LPG 누출 및 증기운에 의한 피해 영향 범위 분석)

  • Gu, Yun-Jeong;Song, Bonggeun;Lee, Wonhee;Song, Byunghun;Shin, Junho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.27-35
    • /
    • 2022
  • When LPG leaks from the storage tank, the gas try to sink to the ground because LPG is heavier than air. The gas easily creates vapor clouds causing aggressive accidents in no airflow. Therefore, It is important to prevent in advance by analyzing the damaged range caused from LPG leakage and vapor clouds. So, this study analyzed the range of damaged by LPG leakage and vapor clouds with consideration of the cold air flow which is generated by the topographical characteristics and the land use status at night time in the Jeju Hagari. As a result of the cold air flow using KLAM_21, about 2 m/s of cold air was introduced in from the southeast due to the influence of the terrain. The range of damaged by LPG leakage and vapor cloud was analyzed using ALOHA. When the leak hole size is 10 cm at the wind speed of 2 m/s, the range corresponding to LEL 60 % (12,600 ppm) was 61 m which range is expected to influence in nearby residential areas. These results of this study can be used as basic data to prepare preventive measures of accidents caused by vapor cloud. Forward, it is necessary to apply CFD modeling such as FLACS to check the vapor cloud formation due to LPG leakage in a relatively narrow area and to check the cause analysis.

On Long Range Transport of Air Pollutants - Sources and Observations of Yellow Sand, TSP and Sulphate in Korea (대기오염의 장거리 이동 사례연구 : 황사, TSP, Sulphate의 발원지 추적)

  • 정용승;김태군
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.197-202
    • /
    • 1991
  • It is observed that the outbreak of dust storms (yellow sand) from Northern China and Mongolia occurs a few times in April 1988 and 1990. It is found that a dust storm initiated with strong gusty winds after the passage of a cold front, particularly after defrost of the ground surface of a source region in the early spring. According to meteorological chart, satellite images and trajectory analyses, dust clouds invaded Korea in April 1988 and 1990 were landing in the sink area after 2 $\sim$ 4 days travelling for 2,000 $\sim$ 3,000 km from a source region. It was also observed that in the west coast total suspended particulated (TSP) were 100 $\sim$ 200 $\mug m^{-3}$ and sulphates $(SO_4=)$ were 3 $\sim$ 10 $\mug m^{-3}$. These values clearly exceed the concentrations of a background level measured in the Arctic and Atlantic Ocean. Trajectory analyses and meteorological analyses suggest that the high values occurred with prevailing westerly flows coming from anthropogenic sources in China. High concentrations of air pollutants occurred in the backside of an anticyclone and in the area "col".col".uot;.

  • PDF

A Study on the Performance of Thermoelectric Module and Thermoelectric Cooling System (열전소자 및 열전냉각장치의 성능에 관한 연구)

  • 유성연;홍정표;심우섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • Thermoelectric module is a device that can produce cooling in a direct manner using the electrical energy. The purpose of this study is to investigate the performance of thermoelectric module and cooling system equipped with the thermoelectric module. The performance of a thermoelectric module is estimated using two methods; theoretical analysis based on one-dimensional energy equations and experimental tests using heat source, heat sink and brass conduction extenders. For the thermoelectric cooling system, the temperatures in the chamber are recorded and then compared with those of lumped system analysis. The results show that the cooling capacity and COP of the thermoelectric module increases as the temperature difference between hot and cold surface decreases, and there is particular current at which cooling capacity reaches its maximum value. The experimental results for the thermoelectric cooling system are similar to those of lumped system analysis.

Experimental Study of Power Generation Performance of Small-Scale Thermoelectric System (소규모 산업 폐열회수용 열전발전시스템의 출력 특성에 관한 실험적 연구)

  • Chung, Jae-Hoon;Kim, Woo-Chul;Lee, Jin-Ho;Yu, Tae-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.383-390
    • /
    • 2010
  • In this study, a thermoelectric power generation system was constructed for a waste-heat recovery. Thermoelectric modules were attached to a stainless steel duct, and a hot air blower was set such that it faced the duct inlet. We found that to achieve the maximum power out of the system, the temperature in the hot side of the thermoelectric module should be uniform. The optimum compressive pressure exerted on the module was observed. Further, the thermoelectric power performance was evaluated using the heat sink attached to the cold side of the thermoelectric module. In particular, when using a natural-convection heat sink, the power output difference is approximately five times.

Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR (소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계)

  • Kim, Nak Hyun;Lee, Sa Yong;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

Computational Thermal Flow Analysis of a Cabin Cooler for a Commercial Vehicle (상용차용 캐빈냉방기의 전산 열유동 해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2012
  • The steady three-dimensional computational thermal flow analysis using standard k-${\varepsilon}$ turbulence model was carried out to investigate the heat transfer characteristics of a cabin cooler for a commercial vehicle. The heat exchanging method of this cabin cooler is to use the cooling effect of a thermoelectric module. In view of the results so far achieved, the air system resistance of a cabin cooler is about 12.4 Pa as a static pressure, and then the operating point of a cross-flow fan considering in this study is formed in the comparatively low flowrate region. The air temperature difference obtained from the cold part of an thermoelectric module is about $26^{\circ}C$, and the cooling water temperature difference obtained from the hot part of an thermoelectric module is about $3.5^{\circ}C$.

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.

Survey on the Kitchen Machinery for the Production of Convenient Foods (Dosirak) in Korea (국내도시락 생산업체의 기기류현황 분석)

  • Park, Hyung-Woo;Koh, Ha-Young;Kang, Tong-Sam;Shin, Dong-Hwa
    • Journal of the Korean Society of Food Culture
    • /
    • v.2 no.2
    • /
    • pp.163-167
    • /
    • 1987
  • To determine and improve the holding machinery for the productin of convenient food (Dosirak) making Compnay in Seoul and Kyeongkido, a survey was conducted of 16 relative companys in 1986. The majority of the holding machinery are composed to work table, sink, rice cooker and fryer. It is necessary that the machinery are reinforced like packaging machine, air cleaner, cold and refrigeration room, sanitary arrangements.

  • PDF

The Impact of Air Temperature During the Growing Season on NEE of the Apple Orchard (사과 생육기의 기온이 사과원의 NEE에 미치는 영향)

  • Kim, Gun-Yeob;Lee, Seul-Bi;Lee, Jong-Sik;Choi, Eun-Jung;Ryu, Jong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1211-1215
    • /
    • 2012
  • Terrestrial ecosystem are a strong sink of carbon. Forest ecosystem, one of them, has been expected to play an important role in climate changing process by absorbing atmospheric carbon dioxide. On the other hand, agricultural ecosystem that consists mainly of annual crops is regarded as poor contributor to carbon accumulation, because its production (carbon hydrate) is decomposed into carbon at a short period, which is emitted to the atmosphere. However, it is thought that fruit tree plays a great role in decreasing atmospheric carbon dioxide concentration, same as forest. Net ecosystem exchange of $CO_2$ (NEE) was measured to estimate carbon fixation capacity using an eddy covariance (EC) system method in 2 years from 2005 to 2006 at an apple orchard in Uiseong, Gyeongbuk. Average air temperature values were higher in 2006 than in 2005 during the dormant season, and lower by about $5^{\circ}C$ over the growing season causing visible cold injuries. Accordingly, we investigated long-term exchange of carbon to determine how much difference of carbon fixation capacity was shown between 2006 and 2005 in terms of environmental and plant variables such as NEE, leaf area index (LAI), and Albedo. NEE was $4.8Mg\;C\;ha^{-1}yr^{-1}$ in 2005 and $4.7Mg\;C\;ha^{-1}yr^{-1}$ in 2006, respectively. Low temperature after July in 2006 decreased LAI values faster than those in 2005. Meanwhile, Albedo values were higher after July in 2006 than in 2005. These results show that the low temperature after July in 2006 apparently affected apple growth.

Climatological Characteristics in the Variation of Soil temperature in Korea (우리나라 지중온도 변동의 기후학적 특성)

  • Kim Seoung-Ok;Suh Myoung-Seok;Kwak Chong-Heum
    • Journal of the Korean earth science society
    • /
    • v.26 no.1
    • /
    • pp.93-105
    • /
    • 2005
  • Climatological characteristics in the variation of soil temperatures in Korea were investigated using Korea Meterological Administration's observation data. And the impacts of soil moisture on the variation of soil temperature were examined using observed precipitation data. The climatological averages of soil temperatures are ranged from 14.4 to $15.0^{\circ}C$ regardless of depths. And they showed an latitudinal gradient with a warm temperature at the southern region and 'U' shape as in the air temperature with a high value along the coastal region. The relatively higher heat capacity and low conductivity of soil compared to those of the air resulted in the significant delay of the maximum and minimum date with depth. As a results, soil acts as a heat source during winter while a heat sink during summer. Global warming and urban heat island have increased the soil temperatures with an average rate $0.3\~0.5^{\circ}C/10-year$ as in the air temperature during last 30 years $(1973\~2002)$. However, the warming rate is maximized during spring contrary to the winter in the air temperature. The temporal variation of soil temperatures is strongly affected by that of soil moisture through an modification of the heat capacity and heat convection. In general, the increased soil moisture clearly decreased the temporal variations and increased the deep layer soil temperatures during cold season.