• Title/Summary/Keyword: coaxial

Search Result 1,000, Processing Time 0.022 seconds

The implementation of interface between industrial PC and PLC for multi-camera vision systems (멀티카메라 비전시스템을 위한 산업용 PC와 PLC간 제어 방법 개발)

  • Kim, Hyun Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.453-458
    • /
    • 2016
  • One of the most common applications of machine vision is quality inspections in automated production. In this study, a welding inspection system that is controlled by a PC and a PLC equipped with a multi-camera setup was developed. The system was designed to measure the primary dimensions, such as the length and width of the welding areas. The TCP/IP protocols and multi-threading techniques were used for parallel control of the optical components and physical distribution. A coaxial light was used to maintain uniform lighting conditions and enhance the image quality of the weld areas. The core image processing system was established through a combination of various algorithms from the OpenCV library. The proposed vision inspection system was fully validated for an actual weld production line and was shown to satisfy the functional and performance requirements.

Exocrine Pancreatic Secretion in Response to Electrical Stimulation of Dorsal Raphe Nucleus in Rats (흰쥐에서 배측 봉선핵의 전기자극이 췌장의 외분비기능에 미치는 영향)

  • Suh, Sang-Won;Park, Hyoung-Jin
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.403-411
    • /
    • 1990
  • The present investigation was performed to see a possible influence of the dorsal raphe nucleus (DRN) on pancreatic exocrine secretion in anesthetized rats since the DRN had been known to exert a regulatory mechanism on sympathetic activity which was known to be very important for pancreatic exocrine secretion, particularly in rats. Twenty-nine Sprague-Dawley rats fasted for 24 hours were anesthetized by i.p. injection of 1 g/kg of urethane. The pancreatic duct was cannulated to collect pancreatic juice while bile juice was diverted into the jejunum. The duodenopyloric junction was tightly ligated. After surgery for collection of pancreatic exocrine secretion and recording of carotid blood pressure, a coaxial electrode was stereotaxically inserted in the DRN with a guide of a brain atlas. And then, electrical stimulus of biphasic square wave with 2 v, 2 msec, 40 Hz was applied on the electrode for 10 minutes. Pancreatic volume flow and protein output secreted in 10 min were measured. Either bilateral cervical vagotomy or spinal cord transection at the level of $C4{\sim}C5$ was performed 20 min prior to stimulation of the DRN. 1) Electrical stimulation of the DRN resulted in significant (p<0.05) increase in pancreatic volume flow and protein output. These stimulatory effects were not affected by cervical vagotomy but completely abolished by cervical cord transection. 2) Electrical stimulation of the DRN also resulted in significant (p<0.05) rise of blood pressure of the carotid artery. The hypertensive effect was not affected by cervical vagotomy but completely abolished by cervical cord transection. The results strongly suggest that the DRN, a part of the central serotonergic system, could exert a stimulatory influence on pancreatic exocrine secretion by increasing the sympathetic activity in anesthetized rats.

  • PDF

Development of 30-Tonf LOx/Kerosene Rocket Engine Combustion Devices(I) - Combustion Chamber (추력 30톤급 액체산소/케로신 로켓엔진 연소장치 개발(I)-연소기)

  • Choi, Hwan-Seok;Han, Young-Min;Kim, Young-Mog;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1027-1037
    • /
    • 2009
  • The development of a combustion chamber for a 30-$ton_f$ regeneratively-cooled space liquid rocket engine is described. Starting from the development of bi-propellant swirl coaxial injectors, essential technologies were verified through subscale combustion chambers and afterwards applied to the full-scale combustion chambers. A total of 5 full-scale combustion chambers have been utilized to verify ignition, combustion efficiency and stability, cooling, and duration requirements. A total of 46 combustion tests were performed among which 23 tests were parallely performed with stability rating tests using a pulse gun device. The test results have revealed that the 30-$ton_f$ regeneratively-cooled combustion chamber fully complies to the performance and combustion stability requirements and thus concluded that the development is successfully completed.

Design and Implementation of Economical Security Monitoring System (경제적인 보안 모니터링 시스템 설계 및 구현)

  • Ryu, Seok-Ki;Lee, Sun-Heum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1101-1107
    • /
    • 2010
  • DVR is widely used in the security monitoring system because it has excellent performance compared with VCR. In this paper, the new DVR interfaces and repeaters enhancing the performance of the existing DVR have been designed and implemented, which enables a large-scaled security monitoring system to be built economically. A repeater in this paper connects 8 monitoring terminals to 2 channels of DVR and a DVR interface manages 16 repeaters to be able to accommodate 128 monitoring terminals. Eventually, the implemented system has a quadruple scalability compared to the existing systems and can reduce the installation cost substantially by using cost-effective UTP cables instead of coaxial cables. And the system could be effectively used in various environments and conditions because various functions such as video transmission, audio communication, emergency call, and RFID card are integrated into the system.

Study on a Coaxial Plasma Gun (III)

  • Bak, Hae-Ill;In, Sang-Ryul;Chung, Kie-Hyung;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.163-170
    • /
    • 1980
  • A Mather type plasms gun is operated at below 1 torr with a energy storage system (4KJ, 16.5KV, 35nH) to study the conditions of the efficient plasma focus. When the $D_2$ gas filling pressure is 0.18 torr and the stored energy is 3.8KJ, the discharge current of max. 180KA is obtained and the average axial velocity of the plasma is about $7cm/\mu\textrm{s}$. This is lower than the calculated velocity with above conditions by the snow-plow model. The discrepancy is due to the currents flowing over the insulator surface. The plasma focus occurs at low pressure compared with the results obtained by Bruzzone. The reasons are such that the plasma gun employed in this experiment is large for tile stored energy and the concentration of the residual gas is comparatively high. It is confirmed by a Long counter that the neutrons are generated from the dense plasma focus.

  • PDF

Effects of the Recess and Propellants Mass Flow on the Flammability Limit and Structure of Methane-Oxygen Diffusion Flame (인젝터 리세스와 추진제 공급유량이 메탄-산소 확산화염의 가연한계와 구조에 미치는 영향)

  • Hong, Joon Yeol;Bae, Seong Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.28-35
    • /
    • 2018
  • In order to analyze the flammability limit and structure of the gaseous methane-gaseous oxygen diffusion flame formed through a shear coaxial injector, combustion experiments were carried out according to the condition of injector recess and propellant mass-flow rate. As a result, it was confirmed that stable anchored flame was observed even at the high oxygen Reynolds number as the propellant momentum flux ratio increased, and that the recess had no significant influence on the flame shape and flammability limit. The anchored flame visualized through a chemiluminescence showed the maximum OH radical emission intensity at a specific position, irrespective of the propellant injection condition, and the radical intensity was greatly reduced by the injector recess.

Plasma Rotation in Plasma Centrifuge with an Annular Gap (동심 원통형 용기내에서의 플라즈마 회전)

  • Hue Yeon Lee;Sang Hee Hong
    • Nuclear Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.78-85
    • /
    • 1982
  • The steady-state rotation of plasma centrifuge is theoretically analyzed to understand the physics of rotating plasmas and its feasibility for isotope separation. The centrifuge system under consideration consists of an annular gap between coaxial cylindrical anode and cathode in the presence of an externally-applied axial magnetic field. A problem for coupled partial differential equations describing centrifuge fields is formulated on the basis of the magnetohydrodynamic equations. Two-dimensional solutions are found analytically in the form of Fourier-Bessel series. The current density and velocity distributions are discussed in terms of the Hartmann number and the geometrical parameter of the system. At typical conditions, rotational speeds of the plasma up to the order of 10$^4$m/sec are achievable, and increase either with increasing Hartmann number, or with increasing ratio of the axial length to the inner radius of the cylinder. In view of much higher speeds of rotation which can be achieved in plasma centrifuge, it is expected that its efficiency is superior to mechanically driven gas centrifuges.

  • PDF

Performance analysis of Coaxial Propeller for Multicopter Type PAV (Personal Air Vehicle) (멀티콥터형 PAV(Personal Air Vehicle)의 동축반전 프로펠러에 대한 성능해석)

  • Kim, Young Tae;Park, Chang Hwan;Kim, Hak Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.56-63
    • /
    • 2019
  • Performance analyses were performed on a propeller developed for use in a PAV (Personal Air Vehicle) under 600 kg Maximum Take-Off Weight (MTOW). The actuator disc theory and CFD analyses were used to estimate the hovering time with regards to MTOW variation for a given battery weight. The interference induced power factor kint was introduced to account for the effect of flow interference between the propellers and to estimate the performance of counter-rotating propellers. The Maximum Figure of Merit (FM) value of the propeller pitch was determined and the design RPM range for the required power inversely obtained from the CFD results. Previous research indicate that the flight time of large multi-copter is limited by the available battery energy density. Similarly, the propeller pitch settings and spacing are important factors in reducing the kint value.

Improvement for Shielding Effectiveness of EMI Shield Layers using Conformal Spray Coating Scheme (콘포멀 스프레이 코팅으로 형성한 EMI 차단막의 차폐효과 개선)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.107-112
    • /
    • 2018
  • Shielding effectiveness (SE) improvement with EMI shield layers fabricated by conformal spray coating system was studied. Silver or Nickel powder filled acrylic resin were sprayed on the samples. We compared the performance with the viscosity of 400 cPs and 100 cPs cases. The thickness range of the coating layer was 20 to 50 um for the silver, 60 to 120 um for the nickel. The shielding effectiveness was measured by ASTM D4935 using coaxial type TEM-cell. The silver-filled resin showed much better performance than that of the nickel-filled resin. The shielding effectiveness increased almost proportional to the thickness of the coating layers until being saturated around 63 dB for the silver-layer or around 34 dB for the nickel-layer. The best performance measured in this study was the shielding effectiveness of 63 dB with $35{\mu}m-thick$ of silver-layer.

Analysis for Shielding Effectiveness of EMI Spray Coating Layers in 3D Structure (3차원 구조에서 EMI 스프레이 코팅막의 차폐효과 분석)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.35-39
    • /
    • 2019
  • The shielding effectiveness (SE) of the EMI spray coating film was measured in a three-dimensional structure. The shielding effectiveness was measured by AST D4935 using coaxial type TEM cell. A standard sample of the cylindrical slab is fabricated to measure the shielding effectiveness using the ASTM D4935. At this time, spray coating was performed by bonding a three-dimensional structure with NAND flash memory to a standard sample. In the case of spray coating, it was uniformly coated not only on the horizontal plane but also on the vertical plane of the three-dimensional structure. As a result of measurement, shielding effectiveness of maximum 59 dB was measured in a three-dimensional structure similar to the case without three-dimensional structure. As a result, it was confirmed that the spray coating can be uniformed even in the three-dimensional structure.