• Title/Summary/Keyword: co-cycle

Search Result 1,786, Processing Time 0.035 seconds

Experimental study on damage and debonding of the frozen soil-concrete interface under freeze-thaw cycles

  • Liyun Tang;Yang Du;Liujun Yang;Xin Wang;Long Jin;Miaomiao Bai
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.663-671
    • /
    • 2023
  • Freeze-thaw cycles induce strength loss at the frozen soil-concrete interface and deterioration of bonding, which causes construction engineering problems. To clarify the deterioration characteristics of the interface under the freeze-thaw cycle, a frozen soil-concrete sample was used as the research object, an interface scanning electron microscope test under the freeze-thaw cycle was carried out to identify the micro index information, and an interface shear test was carried out to explore the loss law of interface shear strength under the freeze-thaw cycle. The results showed that the integrity of the interface was destroyed, and the pore number and pore size of the interface increased significantly with the number of freeze-thaw cycles. The connection form gradually deteriorates from surface-to-surface contact to point-to-surface contact and point-to-point contact, and the interfacial shear strength decreases the most at 0-3 freeze-thaw cycles, with small decreases from to 3-8 cycles. After 12 freeze-thaw cycles, the interfacial shear strength tends to be stable, and shear the failure occurs internally in the soil.

Effects of Multiple-Cycle Operation and SO2 Concentration on CO2 Capture Capacity of Three Limestones in a Fluidized Bed Reactor (유동층 반응기에서 세 가지 석회석의 CO2 흡수능력에 미치는 반복횟수와 SO2 농도의 영향)

  • Ryu, Ho-Jung
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.44-51
    • /
    • 2006
  • Effects of multiple-cycle operation and $SO_2$ concentration on $CO_2$ capture characteristics of three limestones were investigated in a fluidized bed reactor. For each of these sorbents, the measured $CO_2$ capture capacity decreased as the number of cycles increased and as the $SO_2$ concentration increased. On the other hand, the $SO_2$ capture increased with the increased number of cycles and the $SO_2$ concentration. The total calcium utilization decreased as the number of cycles increased, but the effect of $SO_2$ concentrations on the total calcium utilization depended on the type of limestone. For Strassburg limestone, the total calcium utillization decreased with increasing $SO_2$ concentration. However, for Luscar and Danyang limestones, the total calcium utilization was almost independent of $SO_2$ concentration for the range investigated. The results showed that $SO_2$ in flue gas reduced the $CO_2$ capture capacity of limestone and that the sulfation pattern affected the $CO_2$ capture capacity.

Characterization of Potassium Based Dry CO2 Sorbents Developed for the Reduction of Side Reactions (부반응 저감 조성 K계 건식 CO2 흡수제 특성평가)

  • Jang, Young-shin;Kim, Ui-sik;Yoon, Yang-no;Baek, Jeom-In
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.337-341
    • /
    • 2019
  • In this study, the effects of two materials, active alumina and CaO based inorganic binder, which cause the side reaction on the K2CO3-based solid CO2 sorbents was investigated. K2CO3-based solid sorbents called KAM series was prepared by spray drying method and then measured its physical properties and CO2 sorption capacity. Among the KAM series sorbents, KAM(0.5) maintained high CO2 sorption capacity of 7.6 wt% after 3 cycle of sorption/regeneration reaction and showed very low attrition loss as low as 3.1 % which was measured by ASTM D5757-95.

Gas cooling heat transfer coefficient for $CO_2$-PEC9 mixture under supercritical condition (초임계조건에서 $CO_2$-PEC9 혼합물의 물성예측을 통한 냉각 열전달특성 연구)

  • Yun, Rin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.821-826
    • /
    • 2009
  • Due to environmental concerns $CO_2$ has been reintroduced as a potential candidate to replace HFCs in refrigeration systems. Oils are always required in a vapor-compression cycle, and thus actual working fluid in the system is $CO_2$-oil mixtures even though the oil concentrations are low at the heat exchangers and the expansion device. The cooling heat transfer coefficients for $CO_2$-oil mixtures under supercritical condition are required to designing of the gas cooler in the $CO_2$ refrigeration system properly. In the present study, the gas cooling heat transfer coefficients for $CO_2$-PEC9 was estimated by using the Gnileinski correlation, and the Kim and Ghajar model through the previous prediction models for the thermo-physical properties of $CO_2$-oil mixture. The Gnileinski correlation was used when the oil wt.% in the mixture is less than 1.0, and for the higher oil concentration the Kim and Ghajar model was applied. The estimated results agree with the experimental results conducted by the Dang et al.

  • PDF

Electrochemical Properties of LiCoO2 Prepared by Mechanochemical Process (Mechanochemical Process로 제조된 LiCoO2의 전기화학적 특성)

  • Cho, Byung-Won;Lee, Joong Kee;Lee, Jae-Ryong;Kim, Su-Jin;Lee, Kwan-Young;Na, Byung-Ki
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.69-75
    • /
    • 2008
  • Discharge capacity of $LiCoO_2$ in preparation by mechanochemical process decreased remarkably over 4.3V. However, Zr coating of $LiCoO_2$ showed very stable electrochemical properties up to 4.5V. Zr coating of $LiCoO_2$ in this experiment showed the discharge capacity of 197 mAh/g at 3.0-4.5V, and it maintained 96% of the initial discharge capacity after 50 cycle of charge/discharge.

Characteristics and Economic Evaluation of a CO2-Capturing Repowering System with Oxy-Fuel Combustion for Utilizing Exhaust Gas of MCFC (MCFC 배기가스를 이용하는 순산소연소 $CO_2$ 회수형 발전시스템의 특성과 경제성 평가)

  • Pak, Pyong-Sik;Lee, Young-Duk;Ahn, Kook-Young;Jeong, Hyun-Il
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2940-2945
    • /
    • 2008
  • The scale of 2.4 MW MCFC was taken to construct a high-efficiency and economical power generation system without CO2 emission into the atmosphere for utilizing its exhaust gas. The conventional steam turbine power generation system (STGS) was evaluated and the net generated power (NGP) was estimated to be only 133 kW and the STGS is not economically feasible. A CO2-caputuring repowering system was proposed, where low temperature steam (LTS) produced at HRSG by using exhaust gas from MCFC is utilized as a main working fluid of a gas turbine, and the temperature of LTS was raised by combusting fuel in a combustor by using pure oxygen, not the air. It has been shown that NGP of the proposed system is 264 kW, and CO2 reduction amount is 608 t-CO2/y, compared to 306 t-CO2/y of STGS. The CO2 reduction cost was estimated to be negligible small, even when the costs of oxygen production and CO2 liquefaction facilities etc. were taken into account.

  • PDF

Prediction of Density and Viscosity for $CO_2$-PEC9 Mixture at Low Oil Concentration (낮은 오일 농도에서 $CO_2$-PEC9 혼합물의 밀도와 점성 예측)

  • Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.733-738
    • /
    • 2008
  • Due to environmental concerns $CO_2$ has been reintroduced as a potential candidate to replace HFCs in refrigeration systems. Oils are always required in a vapor-compression cycle, and thus it is necessary to precisely estimate the thermodynamic mixture properties of $CO_2$-lubricant oil. In the present study, the density and the viscosity of the mixture was calculated by the Redlich and Kwong type EoS and the modified Peng and Robinson type viscosity EoS, respectively. The viscosity model was based on the similarity between P-v-T and T-$\mu$-P relationships. The predicted results were compared with the experimental data of Pens ado et al. whose test conditions were 100$\sim$650 bar of pressure and 303 K$\sim$353 K of temperature with the $CO_2$-POEs mixtures under 92.2 wt.% and 83.3 wt.% of $CO_2$ concentration. The mean deviations of the mixture density were 7.93% and 8.32% for 92.2 wt.% and 83.3 wt.% of $CO_2$ concentration, respectively. Concerning the viscosity, the mean deviations were 4% and 10% for 92.2 wt.% and 83.3 wt.% of $CO_2$ concentration under the Pensado et al.'s test conditions.

Synthesis and Electrochemical Performance of Ni-rich NCM Cathode Materials for Lithium-Ion Batteries (리튬이온전지 양극활물질 Ni-rich NCM의 합성과 전기화학적 특성)

  • Kim, Soo Yeon;Choi, Seung-Hyun;Lee, Eun Joo;Kim, Jeom-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.4
    • /
    • pp.67-74
    • /
    • 2017
  • Layered Ni-rich NCM cathode materials $Li[Ni_xCo_{(1-x)/2}Mn_{(1-x)/2}]O_2$ ($x{\geq}0.6$) have advantages of high energy density and cost competitive over $LiCoO_2$. The discharge capacity of NCM increases proportionally to the Ni contents. However, there is a problem that it is difficult to realize the stable electrochemical performance due to cation mixing. In this study, synthesis conditions for the layered Ni-rich NCMs are investigated to achieve deliver the ones having good electrochemical performances. Synthesis parameters are atmosphere, lithium source, synthesis time, synthesis temperature and Li/M (M=transition metal) ratio. The degree of cation mixing gets worse as the Ni content is increased from $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ (NCM6) to $Li[Ni_{0.8}Co_{0.1}Mn_{0.1}]O_2$ (NCM8). It is confirmed that higher level of cation mixing affects negatively on the electrochemical performance of NCMs. Optimum synthesis conditions are explored for NCMx (x=6, 7, 8) in order to reduce the cation mixing. Under optimized conditions for three representative NCMx, a high initial discharge capacity and a good cycle life are obtained for $180mAh{\cdot}g^{-1}$, 96.2% (50 cycle) in NCM6, $187mAh{\cdot}g^{-1}$, 94.7% (50 cycle) in NCM7, and $201mAh{\cdot}g^{-1}$, 92.7% (50 cycle) in NCM8, respectively.

Coexpression of PCNA and p21 for DNA repair in small intestinal crypt cells of mouse with 60Co γ-rays irradiation (방사선을 조사한 마우스의 소장 음와세포에서 DNA 수복을 위한 PCNA와 p21의 발현 양상)

  • Hong, Suji;Hwang, Insun;Ahn, Meejung;Shin, Taekyun;Joo, Hong-gu;Park, HyunJeong;Jee, Youngheun
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • The irradiation of radioactive ${\gamma}-ray$ induces apoptosis of radiosensitive organs for homeostasis. In this study, we investigated the repair mechanisms for homeostasis in the small intestine after cell damage by $^{60}Co\;{\gamma}-ray$ irradiation. The apoptosis was most frequently observed in the crypt cells of the small intestine after four and six hours by radioactive ${\gamma}-ray$ irradiation, and the frequency of apoptosis was proportional to the amount of irradiation. Also, the number of apoptotic cells was coincident with expression pattern of p53. Interestingly, PCNA (proliferating cell nuclear antigen) which is engaged in DNA replication and repair was expressed in apoptotic cells of small intestinal crypts. Also, it was observed that cell-cycle regulator p21 which is known to induce cell-cycle arrest is co-expressed in the same apoptotic cells of irradiated small intestinal crypt cells. These findings suggest that the co-expression of PCNA and p21 proteins, which may lead to resistance to DNA damage through cell-cycle arrest is closely associated with repair of damaged gastrointestinal cells after ${\gamma}-ray$ irradiation.

Simulation Study on the Cooling Performance of the Two-Stage Compression CO2 Cycle with the a Flash Intercooler and Flash Gas Bypass (플래쉬 중각냉각기와 플래쉬 가스 바이패스를 이용한 이단압축 이산화탄소 사이클의 냉방성능에 관한 해석적 연구)

  • Kwak, Myoung-Seok;Cho, Hong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.17-24
    • /
    • 2012
  • There has been little study on the performance characteristics of the effective heat pump systems in the cooling mode using the two-stage compression cycles have hardly performed. In this study, the performance of the two-stage compression $CO_2$ cycle with an FI (flash intercooler) and the FGB (flash gas bypass) was investigated by using a theoretical method. The performance analysis was carried out with aby varyingiation (the indoor temperature, outdoor temperature, and 1st- and 2nd-stage EEV openings. As of a result, the coefficients of performance (COPs) of the Bbasic, FI, and FGB cycles were decreased by 28.5%, 22.1%, and 24.5%, respectively, for various outdoor temperature conditions. In addition to, the performance variation of the two-stage compression cycle was smaller than that of the single-stage compression cycle. The performance of the FI and FGB cycles was improved by 13.5%, and 6.9%, respectively, when the 1st-stage EEV opening was increased from 32% to 48%, and by 0.9%, and 2.6%, respectively, when the 1st- andthe 2nd-stage EEV opening was increased from 32% to 48%, andwas increased from 42% to 58%, respectively. The FI cycle showed anthe most improved performance for any given operating conditions.