• Title/Summary/Keyword: clear images

Search Result 468, Processing Time 0.024 seconds

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

A Watermarking for Text Document Images using Edge Direction Histograms (에지 방향 히스토그램을 이용한 텍스트 문서 영상의 워터마킹)

  • 김영원;오일석
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.2
    • /
    • pp.203-212
    • /
    • 2004
  • The watermarking is a method to achieve the copyright protection of multimedia contents. Among several media, the left documents show very peculiar properties: block/line/word patterning, clear separation between foreground and background areas. So algorithms specific to the text documents are required that meet those properties. This paper proposes a novel watermarking algorithm for the grayscale text document images. The algorithm inserts the watermark signals through the edge direction histograms. A concept of sub-image consistency is developed that the sub-images have similar shapes in terms of edge direction histograms. Using Korean, Chinese, and English document images, the concept is evaluated and proven to be valid over a wide range of document images. To insert watermark signals, the edge direction histogram is modified slightly. The experiments were performed on various document images and the algorithm was evaluated in terms of imperceptibility and robustness.

Rural Land Cover Classification using Multispectral Image and LIDAR Data (디중분광영상과 LIDAR자료를 이용한 농업지역 토지피복 분류)

  • Jang Jae-Dong
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.101-110
    • /
    • 2006
  • The accuracy of rural land cover using airborne multispectral images and LEAR (Light Detection And Ranging) data was analyzed. Multispectral image consists of three bands in green, red and near infrared. Intensity image was derived from the first returns of LIDAR, and vegetation height image was calculated by difference between elevation of the first returns and DEM (Digital Elevation Model) derived from the last returns of LIDAR. Using maximum likelihood classification method, three bands of multispectral images, LIDAR vegetation height image, and intensity image were employed for land cover classification. Overall accuracy of classification using all the five images was improved to 85.6% about 10% higher than that using only the three bands of multispectral images. The classification accuracy of rural land cover map using multispectral images and LIDAR images, was improved with clear difference between heights of different crops and between heights of crop and tree by LIDAR data and use of LIDAR intensity for land cover classification.

DETECTION OF DUST LOADED AIRMASS IN SEAWIFS IMAGERY: AN EMPIRICAL DUST INDEX IN COMPARISON WITH MODEL-PREDICTED DUST DISTRIBUTION OVER THE PACIFIC IN APRIL,1998

  • Fukushima, H.;Schmidt, M.;Sohn, B.J.;Toratani, M.;Uno, I.
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.89-94
    • /
    • 1999
  • The paper first proposes an empirical algorithm for detecting dust-loaded airmass observed by Sea Wide Field-of-view Scanner (SeaWiFS). The proposed dust index formula is based on the curvature of the spectral reflectance estimated from the SeaWiFS band 4 (510 nm band) through band 8 (865 nm band) data, assuming "clear ocean water" reflectance. Evaluation of the algorithm is made over several typical Asian dust images including the ones over the Pacific in April, 1998, when a major dust event was reported. The study analyzes the performance and the characteristics of the algorithm by comparing the satellite-derived dust index images with contemporaneous columnar concentration of dust particles predicted by a numerical dust transport model. The comparison reveals several small-scale differences although their dust distribution patterns show good agreement generally.

  • PDF

Mechanical and Electrical Properties of Nonwoven Coated with CNFs/PVDF-HFP Composite (탄소나노섬유/PVDF-HFP 복합재로 코팅된 부직포의 역학적 및 전기적 특성 변화)

  • Lee, Sun-Hee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.2
    • /
    • pp.279-284
    • /
    • 2011
  • In this study, the process of preparation nonwoven with coated carbon nano fibers (CNFs) /poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) composite solution is described. The various contents of CNFs/PVDF-HFP composite coated nonwoven were prepared and characterized by morphological, mechanical, and electrical methods. Nonwovens are coated with CNFs/PVDF-HFP composite solution and decreased the pick up ratio with increasing CNFs contents in range from 0% to 16%. In the results of SEM images, it was clear that the CNFs were evenly distributed in coated nonwoven by SEM images, the existence of CNFs in coated nonwoven was confirmed regularly. The mechanical properties of various contents of CNFs/PVDF-HFP coated nonwoven were examined. The tensile linearity and compression linearity increased with increasing CNFs contents. The electrical properties of the CNFs/PVDF-HFP coated nonwoven increased with increasing CNFs contents.

FUV Images and Physical Properties of the OES region

  • Jo, Young-Soo;Min, Kyung-Wook;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.69.2-69.2
    • /
    • 2010
  • The far-ultraviolet (FUV) H2 and C IV emission images and spectra of Orion Eridanus Superbubble (OES) is hereby presented. The OES seems to consists of multiple phase through the detection of highly-ionized gas and pervasive neutral hydrogen. The former is traced by hot gas while the latter is traced by cold medium. A spectral image made with H2 fluorescent emission shows that the spatial distribution of hydrogen molecule is well correlated with the dust map. The model spectra was taken from a photodissociation region (PDR) radiation code which find a best suitable parameter such as hydrogen density, gas temperature and incident uv intensity of the radiation field. C IV emission is caused by intermediate temperature ISM about 10^4.5 K~10^6 K. Therefore we could get more clear evidence to reveal the structure of OES. Feature of spectra for the each sub region is also presented and discussed. The data were obtained with the Far-Ultraviolet Imaging Spectrograph (FIMS) and the whole data handling were followed by previous FIMS analysis.

  • PDF

An Experimental Study on Shallow Water Effect in Slamming (천수에서의 슬래밍 현상에 대한 실험적 연구)

  • Kang, Hyo-Dong;Oh, Seung-Hoon;Kwon, Sun-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.60-66
    • /
    • 2009
  • This study presents an experimental investigation of the shallow water impact of a box type structure. The analysis was done based on the video images captured by a high speed camera, the flow field obtained by PIV (Particle Image Velocimetry), and pressure measurements in the divided region. The video images showed quite good agreement with the description given by Korobkin. The PIV measurements of the velocity field provided a clear view of the flow pattern for all three stages. The pressure was measured at the bottom of the tank with strain gauge type pressure gauges. The pressure measurements showed the characteristics of divided regions.

A RADIOGRAPHIC STUDY OF THE PANORAMIC INNOMINATE LINE II (파노라마 X선사진상의 무명선에 관한 연구 II)

  • Choi Karp-Shik;Lee Kang-Sook
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 1995
  • The purpose of this study was to investigate the changes of the shape of the panoramic innominate line and also to examine the relation of the panoramic innominate line to maxillary posterior wall according to positional changes in panoramic radiographs of the patients who had no pathoses in the maxillary sinus and adjacent bony structures. Thus these panoramic radiographs were obtained and evaluated in standard, forward 10mm, backward 10mm, chin down 10°, and chin up 10° positions. And the following results were obtained : 1. Panoramic innominate lines were not changed in shape according to various positional changes in panoramic radiography. 2. The panoramic innominate line was observed to be more clear images and decreased distance to the posterior wall of maxillary sinus at forward 10mm and chin down 10° positions. And the panoramic innominate line was observed more blurred images and increased distance to the posterior wall of maxillary sinus at backward 10mm and chin up 10° positions.

  • PDF

Circuit Design for Compesation of a Dry Fingerprint Image Quality on Charge Sharing Scheme (전하분할 방식의 건조 지문이미지 보상회로 설계)

  • Jung, Seung-Min;Yeo, Hyeop-Goo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.795-797
    • /
    • 2013
  • This paper describes a charge sharing capacitive-sensing circuit technique that improves the quality of images captured with fingerprint sensor LSIs. When the finger is dry, the electrical resistance of a finger surface is high. It leads to poor image quality. To capture clear images even when the finger is dry, the modified capacitive detection circuit improves the image quality using an enhancement plate at the finger surface and a voltage control circuit. The test circuit is analyzed on $0.35{\mu}m$ CMOS process.

  • PDF

TEMPORAL VARIATIONS OF NO2 DISTRIBUTION OVER AN URBAN AREA MEASURED BY IMAGING DIFFERENTIAL OPTICAL ABSORPTION SPECTROSCOPY

  • Lee, Han-Lim
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.302-305
    • /
    • 2007
  • During the CareBeijing campaign in September 2006, Imaging Differential Optical Absorption Spectroscopy (IDOAS) measurements were made over the city of Beijing, China using a spatial resolution of 146 pixels horizontally and 61 pixels vertically, each with a field of view of $0.133^{\circ}$ and $0.072^{\circ}$ in the horizontal and vertical directions, respectively. Using Fraunhofer reference spectra (FRS) for the evaluation of data for two consecutive days, the diurnal variation of $NO_2$ distributions was determined from data measured every single hour from 08:00 until 16:00 on September 9 and 10. Both days presented a fairly clear sky with high visibility. The setup allowed detailed images of the low surface $NO_2$ distribution over Beijing. Images with less than a 30-min temporal resolution showed variation of plume dispersal in both horizontal and vertical directions. An in-situ measurement was also conducted. Results from both instruments are interpreted by considering local emission sources and wind conditions.

  • PDF