• Title/Summary/Keyword: circulating-bed

Search Result 212, Processing Time 0.019 seconds

Decomposition of Formaldehyde Using TiO$_2$ Photocatalyst Beads by Circulating Fluidized Bed Chemical Vapor Deposition (CFB-CVD법으로 제조된 TiO$_2$ 광촉매 비드를 이용한 포름알데히드의 분해)

  • Kim, Kyoung-Hwan;Kim, Yu-Bong;Lee, Seung-Young;Park, Jae-Hyeon;Lim, Jin-Young;Jung, Sang-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.688-693
    • /
    • 2008
  • TiO$_2$ photocatalyst films deposited beads were prepared by circulating fluidized bed chemical vapor deposition(CFB-CVD) using TTIP(Titanium Tetra Iso-Propoxyde). Photocatalytic activities of Photocatalyst beads were evaluated by decomposition rate of formaldehyde in aqueous solution using a photo-reactor. From the result of photocatalytic degradation of formaldehyde, decomposition rate were shown gradually increased according to the increase of UV intensity, circulating fluid velocity and addition amount of H$_2$O$_2$. However the decomposition rate of formaldehyde were decreased according to the increase of initial concentration and pH value.

Tube Erosion Rate of Water Wall in a Commercial Circulating Fluidized Bed Combustor (상용 순환 유동층 연소로 수관벽 전열관 마모속도)

  • Kim, Tae-Woo;Choi, Jeong-Hoo;Shun, Do-Won;Son, Jae-Ek;Jung, Bongjin;Kim, Soo-Sup;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.525-530
    • /
    • 2005
  • The erosion rate of water wall tube has been measured and discussed in a commercial circulating fluidized bed combustor (200 ton steam/hr, $4.97{\times}9.90{\times}28.98m\;height$). Tube thickness was measured with ultrasonic method. Severe tube erosion rate was observed in the splash region on all waterwalls including wingwalls. The tube erosion rate increased after an initial decrease as height from the distributor increased. The difference of erosion rate among wing walls was found due to unbalanced distribution of gas and solid flow rates. The erosion rate of the wing wall increased as location of the wing wall became closer to the center of combustor crosssection.

Evaluation of Anti-Stripping Performance in Asphalt Concrete using Byproduct Ash produced from Circulating Fluidized Bed Boiler (보일러 부산 애쉬를 이용한 아스팔트 콘크리트의 박리저항성 평가)

  • Kim, Yooseok;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.319-325
    • /
    • 2018
  • Pot-holes are steadily increasing due to abnormal climate such as heavy rainfall and frequent snowfall. Pot-hole related to traffic accidents cause injuries, car damage and distress of road facilities. To reduce pot-holes, the use of an anti-stripping agent is mandatorily recommended to asphalt concrete mixture. Hydrated lime is commonly used as anti-stripping agent due to the convenience and economics. Byproduct ash from circulating fluidized bed boiler was reviewed as an anti stripping agent. According to the test results, the byproduct ash is satisfied with TSR specification using 1% to 3% by weight of the asphalt mixture. The byproduct ash was examined under various condition changes of aggregate and asphalt concrete mixture considering quality movement. According to the results, using the byproduct ash was measured average 0.87 of TSR and coverage rates of 60% after rolling bottle test. Test results also revealed that the byproduct ash showed stable performance. Using the byproduct ash to decrease pot-hole in asphalt concrete pavement is suitable for demonstrating stable performance as anti-stripping agent.

Effects of Alkali Metals and Chlorine on Corrosion of Super Heater Tube in Biomass Circulating Fluidized Bed Boiler (순환유동층보일러의 과열기 튜브 부식에 알칼리 금속과 염소가 미치는 영향)

  • Back, Seung-Ki;Yoo, Heung-Min;Jang, Ha-Na;Joung, Hyun-Tae;Seo, Yong-Chil
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • This study provides the identification of corrosion cause substances in super heater tube from a commercial scale circulating fluidized bed boiler. Electricity is produced by the combustion of biomass mainly wood waste. The biomass, super heater tube, super heater tube ash, and boiler ash were collected and components associated with corrosion were analyzed. A large amount of oxygen-containing material was found due to oxidation. The chlorine content was analyzed as 6.1% and 4.3% in super heater tube ash and boiler ash respectively which were approximately 20 and 14 times higher than those of designed values. Also, alkaline metal contents (K, Na, Ca) were very high in ash samples collected from super heater tube and boiler. The tendency of slagging and fouling was predicted based on X-Ray Fluorescence (XRF) results. Basicity that can lead to slagging was estimated as 3.62 and 2.72 in super heater tube and boiler ash, respectively. Slagging would occur with ash content when considering the designed value as 0.35.

A Tube Thickness Map of Water Wall in a Commercial Circulating Fluidized Bed Combustor (상용 순환 유동층 연소로 수관벽 전열관 두께 지도)

  • Kim, Tae-Woo;Choi, Jeong-Hoo;Shun, Do-Won;Son, Jae-Ek;Jung, Bongjin;Kim, Soo-Sup;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.412-418
    • /
    • 2005
  • The tube thickness map of water wall has been measured in a commercial circulating fluidized bed combustor (200 ton steam/hr, $4.97{\times}9.90{\times}28.98m$ height) with ultrasonic method and tube erosion has been discussed. Severe tube erosion took place in the splash region on all waterwalls including wingwalls. Erosion on the lower part of front and rear walls, close to both side walls, was more serious than other places. Erosion of some tubes around the gas exit was found to be noticible. Tube erosion increased on the wingwall as the position of the tube become closer to the center of the combustor crosssection.

Utilization of Circulating Fluidized Bed Combustion Ash and Related Specifications for Mine Backfills (순환유동층 석탄재의 활용 기술과 광산 채움재 관련 규격 동향)

  • Jang, Jeong Gook;Ji, Sangwoo;Ahn, Ji-Whan
    • Resources Recycling
    • /
    • v.26 no.2
    • /
    • pp.71-79
    • /
    • 2017
  • Circulating fluidized bed combustion (CFBC) ash is one of useful mineralogical resources having abundant content of free lime and anhydrite, and has a self-cementitious property. Recently, considerable interest has been gained regarding the utilization of CFBC ash, along with its use in mine backfill and reclamation. Prior to adopt the use of CFBC ash in the mine backfill technology, discussion on the technology and related specification is prerequisite in the future. This paper presents a review on studies in the emerging technology of CFBC ash utilization, and provides useful information with regard to the specifications for mine backfills utilizing CFBC ash.

Study on the Free CaO Analysis of Coal Ash in the Domestic Circulating Fluidized Bed Combustion using ethylene glycol method (에틸렌글리콜법을 활용한 국내 순환유동층보일러 석탄회의 Free CaO 평가 연구)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Kim, Young-Jin;Choi, Moon-Kwan;Cho, Kye-Hong;Ahn, Ji-Whan
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This study was carried out to physicochemical properties and free CaO contents of coal ash in domestic circulating fludized bed combustion power plant using ethylene glycol method. Results of physicochemical properties, there are many differences in CaO contents for the region position in CFBC plant. The reason, It is considered to be reflected that regulation of exhaust concentration for oxides of sulfur and other operation characteristics of region position in CFBC plant. Free CaO contents are 1.96 ~ 10.78% of fly ash and 0.07~4.24 % of bottom ash, fly ash is higher than in the bottom ash. besides CaO contents of raw materials, particle distribution have a lot of influence Free CaO contents.

Evaluation of Limestone for In-Situ Desulfurization in CFB Boilers (순환유동층 보일러 로내 탈황을 위한 석회석 평가)

  • Lee, See Hoon;Kim, Dong Won;Lee, Jong Min;Bae, Yong Chae
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.853-860
    • /
    • 2019
  • In order to meet more severe environmental regulations, oxy-fuel circulating fluidized bed(CFB) boilers or ultra supercritical CFB boilers, which are a kind of process in that solid particles moves similar to fluid, have been developed in the world. In CFB power generation processes, the method to reduce or remove sulfur dioxide is in-situ desulfurization reaction via limestone directly injected into CFB boilers. However, the desulfurization efficiencies have continuously changed because limestones injected into CFB boilers are affected by various operation conditions (Bed temperature, pressure, solid circulating rate, solid holdup, residence time, and so on). In this study, a prediction method with physical and chemical properties of limestone and operation conditions of CFB boiler for in-situ desulfurization reaction in CFB boilers has developed by integrating desulfurization kinetic equations and hydrodynamics equations for CFB previously published. In particular, the prediction equation for in-situ desulfurization was modified by using experimental results from desulfurization reactions of various domestic limestones.

Characteristics of Carbon Capture by the Accelerated Carbonation Method of Circulating Fluidized Bed Combustion Ash (순환 유동층 보일러 애시의 촉진탄산화에 의한 탄소포집 특성)

  • Choi, Young-Cheol;Yoo, Sung-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.165-172
    • /
    • 2021
  • The purpose of this study is to investigate the carbon capture capacity of various inorganic materials. For this purpose, the change in property of ordinary Portland cement (OPC), blast furnace slag fine powder (GGBS), and circulating fluidized bed boiler ash (CFBC) due to carbonation were analyzed. Carbonation curing was performed on all specimens through the accelerated carbonation experiment, and the amount of carbon capture was quantitatively analyzed by thermogravimetric analysis according to the age of carbonation. From the results, it is confirmed that the carbon capture capacity was shown in all specimens. The carbon capture amount was shown in the order of CFBC, OPC, and GGBS. The 28-day carbon capture of CFBC, OPC, and GGBS was 3.9%, 1.3%, and 9.4%, respectively. Carbon capture reaction occurred rapidly at the beginning of carbonation, and occurred slowly with increasing age. SEM image analysis revealed that an additional product generated by carbonation curing in all specimens was calcium carbonate.

Development of Autoclave Aerated Concrete Using Circulating Fluidized Bed Combustion Ash (순환유동층 보일러애쉬를 활용한 경량기포 콘크리트 개발)

  • Lee, Chang Joon;Song, Jeong-Hyun;Chung, Chul-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.58-65
    • /
    • 2021
  • In this study, as a method to increase the recycling of circulating fluidized bed combustion ash(CFBCA), CFBCA was utilized to produce autoclave aerated concrete product since CFBCA contains quicklime and calcium sulfate components that are required for the manufacture of autoclave aerated concrete. Successful achievement of such objective will bring cost reduction with high value addition, saving of natural resources, and the reduction of environmental load. Various mixing designs were designed to evaluate the properties of autoclave aerated concrete made of CFBCA. Based on series of experimental program, prototypes mix design for factory manufacturing was obtained. According to the experimental results, it was confirmed that gypsum can be replaced with CFBCA through the method of pre-treating the CFBCA as a slurry. It was possible to produce competitive autoclave aerated concrete products using CFBCA.