• Title/Summary/Keyword: circuit protection

Search Result 633, Processing Time 0.029 seconds

Technolgy trends for secondary battery cell and protection circuit (이차전지와 보호회로의 기술 동향)

  • Byun, Jae-in;Kim, Harksoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.752-754
    • /
    • 2014
  • With the rapid development of the portable devices such as laptops, cell phones, digital devices, the important of the secondary battery is increasing. In recent years, semiconductor industries, display technologies, and secondary batteries are believed to be three core business. In particular, smart phones have higher performances, but secondary batteries are not follow the trends. Recently, the stability problem by battery heat is raised. In this paper, we survey technology trends of the secondary battery and protection circuit.

  • PDF

Design of the Noise Margin Improved High Voltage Gate Driver IC for 300W Resonant Half-Bridge Converter (잡음 내성이 향상된 300W 공진형 하프-브리지 컨버터용 고전압 구동 IC 설계)

  • Song, Ki-Nam;Park, Hyun-Il;Lee, Yong-An;Kim, Hyoung-Woo;Kim, Ki-Hyun;Seo, Kil-Soo;Han, Seok-Bung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.7-14
    • /
    • 2008
  • In this paper, we designed the HVIC(High Voltage Gate Driver IC) which has improved noise immunity characteristics and high driving capability. Operating frequency and input voltage range of the designed HVIC is up to 500kHz and 650V, respectively. Noise protection and schmitt trigger circuit is included in the high-side level shifter of designed IC which has very high dv/dt noise immunity characteristic(up to 50V/ns). And also, rower dissipation of high-side level shifter with designed short-pulse generation circuit decreased more that 40% compare with conventional circuit. In addition, designed HVIC includes protection and UVLO circuit to prevent cross-conduction of power switch and sense power supply voltage of driving section, respectively. Protection and UVLO circuit can improve the stability of the designed HVIC. Spectre and Pspice circuit simulator were used to verify the operating characteristics of the designed HVIC.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

A Study on the Design of Green Mode Power Switch IC (그린 모드 파워 스위치 IC 설계에 관한 연구)

  • Lee, Woo-Ram;Son, Sang-Hee;Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • In this paper, Green Mode Power IC is designed to reduce the standby power. The proposed and designed IC works for the Switch Mode Power Supply(SMPS) and has the function of PWM. To reduce the unnecessary electric power, burst mode and skip mode section are introduced and controlled by external power MOSFET to diminish the standby power. The proposed IC is designed and simulated by KEC 30V-High Voltage 0.5um CMOS Process. The structure of proposed IC is composed of voltage regulator circuit, voltage reference circuit, UVLO(Under Voltage Lock out) circuit, Ibias circuit, green circuit, PWM circuit, OSC circuit, protection circuit, control circuit, and level & driver circuit. Measuring the current consumption of each block from the simulation results, 1.2942 mA of the summing consumption current from each block is calculated and ot proved that it is within the our design target of 1.3 mA. The current consumption of the proposed IC in this paper is less than a half of conventional ICs, and power consumption is reduced to the extent of 1W in standby mode. From the above results, we know that efficiency of proposed IC is superior to the previous IC.

Parameters Optimization of Impulse Generator Circuit for Generating First Short Stroke Lightning Current Waveform

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents the parameters optimization technology for generating the first short stroke lightning current waveform($10/350{\mu}s$) which is necessary for the performance tests of components of lightning protection systems, as required under IEC 62305 and the newly amended IEC 62561. The circuit using the crowbar device specified in IEC 62305 was applied to generate the lightning current waveform. To find the proper parameters of the circuit is not easy because the circuit consists of two parts; circuit I, which relates to the front of current waveform, and circuit II, which relates to the tail. A simulation in PSpise was carried out to find main factors related to the front and tail of $10/350{\mu}s$. The lightning current generator was developed by utilizing the circuit parameters found in the simulation. In the result of experiments, new parameters of the circuits need to be changed because of the difference between the simulation and the experiment results. Using the iterative method, the optimized parameters of the circuits was determined. Also a multistage-type external coil and a damping resistor were proposed to make the efficiency of generation to enhance. According to the result in this paper, an optimized first short stroke lightning current waveform was obtained.

A Study on the Novel SCR NANO ESD Protection Device Design and fabrication (새로운 구조의 나노급 ESD 보호소자 설계 및 제작에 관한 연구)

  • Kim, Kui-Dong;Lee, Jo-Woon;Park, Sang-Jo;Lee, Yoon-Sik;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.9 no.2 s.17
    • /
    • pp.161-169
    • /
    • 2005
  • This paper presents the new structural Low voltage LVTSCR and TWSCR ESD protection circuit. The proposed ESD protection circuit has lower triggering voltage than conventional circuits. And the LVTSCR has the triggering voltage of 9V, current of 7mA and can pass below 0.8KV (150mA/um). The triggering voltage of the Triple-well SCR measured to 6V and the current is 40mA. By the substrate and gate bias, the triggering voltage is lowered down to $4{\sim}5.5V$.

  • PDF

A Design of Analog Voltage-controlled Tunable Active Element for Information Protection (정보 보호용 아날로그 전압조절 가변 능동소자 설계)

  • 송제호;방준호
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.10
    • /
    • pp.1253-1260
    • /
    • 2001
  • In this paper, a new voltage-controlled tunable analog active element for low-voltage applications and information protection is proposed. The proposed active element is composed of the CMOS complementary cascode circuit which can extend transconductance of an element. Therefore, the unity gain frequency which is determined transconductance is increased than that of the conventional element. And then these results are verified by the $0.25\mutextrm{m}$ CMOS n-well parameter HSPICE simulation. As a result, the gain and the unity gain frequency are 42㏈ and 200MHz respectively in the element on 2V supply voltage. And power dissipation of the designed circuit is 0.32mW.

  • PDF

Research for Protection Relay of Static Condenser Bank (SC 전용 보호계전기 개발)

  • Jeong, J.K.;Yun, S.Y.;Kim, S.J.;Kim, K.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.48-50
    • /
    • 2006
  • SC(Static Condenser) in KEPCO is used in voltage control and power factor compensation. Currently KEPCO uses SC to 154kv 50MVA and 23kv SMVA. It is not important in old days because a SC bank accident has no effect on power system. But we are interested in the SC bank for power quality in these days. The SC Bank has a reactor and a condenser using series connection. It is operated in critical point for resonance circuit normally. Therefore the SC bank has a small reliability against other Power instruments. If a 4th harmonic frequency as a resonance frequency is supplied in system, the condenser is damaged because of a resonance current. And a trip and a closing for CB(Circuit Breaker) in many times will have a big influence of SC bank destruction. General OCR(Over Current Relay) observing SC bank is not useful for this protection We think that protection relay must be have the SC bank characteristics. A solution for this problem is active Power, resonance frequency and impedance.

  • PDF

Development of chemical conversion coating technology by environment friendly method for Zn electroplated steel (아연 전기 도금 강의 환경친화적인 화성처리 기술 개발)

  • Kim, Seong-Jong;Kim, Jeong-Il;Jang, Seok-Ki
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.271-272
    • /
    • 2006
  • Zinc confers high corrosion resistance by acting as a sacrificial anode, and a zinc coating improves the appearance of steel. Chromate conversion coating (CCC) films are still one of the most efficient surface treatments for steel. Although such films can self-repair via the dissolution of Cr(VI), dissolved Cr(VI) have adverse effects on humans, and the environment. Therefore, we examined the corrosion protection property and morphology of colloidal silica conversion films as an alternative to CCC films. The corrosion behavior was investigated in 3% NaCl solution using electrochemical techniques, including electrochemical impedance spectroscopy, open circuit potential, and the salt spray test(SST). Corrosion was implied by the appearance of red rust on the specimen surface. In corrosion resistance at 3% NaCl solution, red rust appeared at 15-20, 55-70, and 83-98 days on Zn-electroplated steel, colloidal silica conversion-coated specimens, and CCC-coated specimens, respectively. In the salt spray test, the colloidal silica film provided better corrosion protection than CCC films, i.e., red rust appeared at 96 hours on the Zn-electroplated steel sheet, at 432 hours with the CCC films, and at 888 hours with silica conversion coating.

  • PDF

Comparative Study between Two Protection Schemes for DFIG-based Wind Generator Fault Ride Through

  • Okedu, K.E.;Muyeen, S.M.;Takahashi, R.;Tamura, J.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.8-16
    • /
    • 2012
  • Fixed speed wind turbine generators system that uses induction generator as a wind generator has the stability problem similar to a synchronous generator. On the other hand, doubly fed induction generator (DFIG) has the flexibility to control its real and reactive powers independently while being operated in variable speed mode. This paper focuses on a scheme where IG is stabilized by using DFIG during grid fault. In that case, DFIG will be heavily stressed and a remedy should be found out to protect the frequency converter as well as to allow the independent control of real and reactive powers without loosing the synchronism. For that purpose, a crowbar protection switch or DC-link protecting device can be considered. This paper presents a comparative study between two protective schemes, a crowbar circuit connected across the rotor of the DFIG and a protective device connected in the DC-link circuit of the frequency converter. Simulation analysis by using PSCAD/EMTDC shows that both schemes could effectively protect the DFIG, but the latter scheme is superior to the former, because of less circuitry involved.