The study of the protection circuit about overvoltage between excitation system and synchronous machines (여자시스템과 동기발전기의 회전자 권선에 발생되는 과전압에 대한 보호회로 연구)

  • 류호선;임익헌
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.188-192
    • /
    • 1997
  • In the case of synchronous machines, certain power system disturbances cause the induced rotor current to assume negative values when no static converter is present. A converter, however, prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. This newly proposed crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly and verified through experiment

  • PDF

ELECTRICAL FIRE (전기화재)

  • Park, Heon-Sik
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.13-22
    • /
    • 1991
  • To understand electrical fire, the cause of it is classified into overcurrent, short circuit, leak, joint, overheat, accumulation of heat, spark, deterioration of insulation, static electricity, and lightning etc. and explained. And then by the precautions to it, proposed to the improvement of electric products, the completeness of safecty management and the use of alarm systems.

  • PDF

Enhanced Performance of Li Metal Negative Electrode using Protection Film by Carbon Black and Polymeric Binder (카본블랙과 고분자 바인더로 구성된 보호필름을 통한 리튬금속 음극의 성능개선)

  • Noh, Seong Ho;Ryu, Da Young;Jang, Young Seok;Ryu, Ji Heon
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2022
  • In this study, the surface protection film based on organic-inorganic composite is manufactured for suppressing lithium dendrite growth, and the film is applied on the surface of Li metal negative electrode for lithium metal batteries (LMBs). The film is consist of the polyvinylidene fluoride (PVDF) polymeric binder which has good mechanical strength and high electrochemical stability, and carbon black (Super-P) which has outstanding electrical conductivity as the inorganic compound. First, in order to confirm the suppression of the internal short circuit by the lithium dendrite, the time required for the short circuit is measured while a constant current is continuously applied. As a result, the internal short circuit is delayed in proportion to the carbon black content of the film, and it is significantly delayed than bare Li metal electrode which does not use protection film. The cycle performance of the thick protection film (8 ㎛), is worse than that of the thin film (4 ㎛). However, as the carbon black content of the film increased, the cycle performance is improved. Thus, the surface protection film based on carbon black/PVDF composite can delay the internal short circuit, and has low overvoltage during the cycle. However, more stable cycle performance needs to be built through further improvements.

A Study on the Verification Scheme for Electrical Circuit Analysis of Fire Hazard Analysis in Nuclear Power Plant (원전 화재위험도분석에서 전기회로분석 검증방안에 관한 연구)

  • Yim, Hyuntae;Oh, Seungjun;Kim, Weekyong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.114-122
    • /
    • 2015
  • In a fire hazard analysis (FHA) for nuclear power plant, various electrical circuit analyses are performed in the parts of fire loading analysis, fire modeling analysis, separation criteria analysis, associated circuit analysis, and multiple spurious operation analysis. Thus, electrical circuit analyses are very important areas so that reliability of the analysis results should be assured. This study is to establish essential electrical elements for each analysis for verification of the reliability of the electrical circuit analyses in the fire hazard analysis for nuclear power plants. Applying the results derived by the study to domestic nuclear power plants, it is expected to determine the adequacy of the fire hazard analysis report and contribute to the reliability of the fire hazard analysis of those plants.

Development of Protection Device for Voltage Unbalance Faults using Three-Phase Neutral Voltage (삼상 중성점 전압을 이용한 전압불평형 사고 방지용 보호장치 개발)

  • Kwak, D.K.;Kim, D.S.;Kim, J.H.;Kim, S.C.;Jung, W.S.;Son, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.621-622
    • /
    • 2012
  • The thermal over-current relay or electronic motor protection relay is mostly used as the open-phase detection device of the three-phase motor or load. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for open-phase protection using semiconductor devices. Therefore, the proposed open-phase protection device enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight.

  • PDF

Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages (뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석)

  • 이복희;이승칠;김찬오
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.96-103
    • /
    • 1997
  • This paper deals with the malfunction characteristics of the earth leakage circuit breakers(ELBs) applied by a lightning impulse voltage. In the cases of the regulation of KS C 4613 and the simulated circuits with surge protection devices, the dead operation characteristics of the ELBs against lightning impulse voltages were experimentally investigated and discussed. As a result, all the specimens(ELBs) used in this work have a cutoff performance of the lightning impulse voltage when the differential mode surges were injected at the input terminals of the ELBs owing to a surge absorber installed at the power source side of amplification circuit. Four kinds of the specimens have brought about malfunction in the condition of the lightning impulse dead operation test defined in KS C 4613, and the malfunction voltages are relatively high and are about 5-6.5[kV]. In the case of the simulated test circuit with surge protection devicesthree kinds of the ELBs have led to malfunction. Also the voltage level causing the malfunction of the ELBs is decreased by operation of surge protection devices, and it ranges from 3 to 5(kV).

  • PDF

Development of High Efficiency Self Diagnosis Type Neon Transformer using Groin Direction of Non-Oriented Silicon Steel Strip (압연 방향을 적용한 자체 진단형 고효율 네온관용 변압기)

  • 변재영;김윤호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and grain direction of non-oriented silicon steel strip. A protection circuit is designed for all types of neon transformer loaded with one or more neon tubes. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the electronic type protection circuit will be initiated to avoid more critical hazards. These neon transformers need a electronic type protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut on when the abnormal condition occurs, preventing waste of no-load power.

Analysis of Protection Circuits of Overcurent and Overvoltage on Transmission Line Induced by External Electromagnetic Pulse (외부 전자파 펄스에 의해 전송선로에 유기되는 과전류 및 과전압 보호회로의 해석)

  • 하헌태;김세윤;이경재;오명환
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.8-14
    • /
    • 1991
  • A new algorithm for calculation of overcurrent and overvoltage at load for parallel two-wire transmission line with nonlinear protection circuits induced by and external electromagnetic pulse is suggested. The rigorous solution is obtained for a particular type of the incident waveform and protection circuit. The validity of our algorithm is checked by comparing numerical results to the analytic solution in the particular case.

  • PDF

Reliability Analysis of CMOS Circuits on Electorstatic Discharge (CMOS 회로의 ESD에대한 신뢰성 문제 및 보호대책)

  • 홍성모;원태영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.12
    • /
    • pp.88-97
    • /
    • 1993
  • Electrostatic Discharge(ESD) is one of the major reliability, issues for today's VLSI production. Since the gate oxide with a thickness of 100~300$\AA$ is vulnerable to several thousand volt of ESD surge, it is necessary to control the ESD events and design an efficient protection circuit. In this paper, physical mechanism of the catastrophic ESD damage is investigated by transient analysis based upon Human Body Model(HBM). Using two-dimensional electrothermal simulator, we study the failure mechanism of the output protection devices by ESD and discuss the design issues for the optimun protection network.

  • PDF

A study on Protective Coordination of MCA for Performing of the Pad Mounted Transformer's inside Protective Device (지상변압기의 내부 보호장비 작동을 위한 MCA 보호협조에 대한 연구)

  • Hyun, Seung-Yoon;Kim, Chang-Hwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.5-7
    • /
    • 2022
  • KEPCO's plan is undergoing a trial operation to replace the open-loop section with ring main units configuration where underground distribution lines are installed, by linking the multi-way circuit breakers auto (MCA) on the power side of each pad-mounted transformer. However, ring main units application mentioned above may cause the ripple effects, when implementing the configuration without a study of protection coordination. Because ring main units with classical pre-set protection devices contribution in fault condition didn't consider yet. For the reliable ring main units operation, it is necessary to resolve several protection issues such as the protection coordination with substation side, prevention of the transformer inrush current. These issues can radically deteriorate the distribution system reliability Hence, it is essential to design proper protection coordination to reduce these types of problems. This paper presents a scheme of ring main units' configuration and MCA's settings of time-current curves to preserve the performance of protection coordination among the switchgears considering constraints, e.g. prevention of the ripple effects (on the branch section when a transformer failure occurs and the mainline when a branch line failure occurs). It was confirmed that the propagation of the failure for each interrupter segment could be minimized by applying the proposed TCC and the interrupter settings for the MCAs (branch, transformer). Further, it was verified that the undetected area of the distribution automation system (DAS) could be supplemented by having the MCA configurated ring main units operate first, instead of the internal protection equipment in the transformer such as the fuse, STP when a transformer failure occurs.