• Title/Summary/Keyword: circuit modeling

Search Result 821, Processing Time 0.029 seconds

Bubbly, Slug, and Annular Two-Phase Flow in Tight-Lattice Subchannels

  • Prasser, Horst-Michael;Bolesch, Christian;Cramer, Kerstin;Ito, Daisuke;Papadopoulos, Petros;Saxena, Abhishek;Zboray, Robert
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.847-858
    • /
    • 2016
  • An overview is given on the work of the Laboratory of Nuclear Energy Systems at ETH, Zurich (ETHZ) and of the Laboratory of Thermal Hydraulics at Paul Scherrer Institute (PSI), Switzerland on tight-lattice bundles. Two-phase flow in subchannels of a tight triangular lattice was studied experimentally and by computational fluid dynamics simulations. Two adiabatic facilities were used: (1) a vertical channel modeling a pair of neighboring sub-channels; and (2) an arrangement of four subchannels with one subchannel in the center. The first geometry was equipped with two electrical film sensors placed on opposing rod surfaces forming the subchannel gap. They recorded 2D liquid film thickness distributions on a domain of $16{\times}64$ measuring points each, with a time resolution of 10 kHz. In the bubbly and slug flow regime, information on the bubble size, shape, and velocity and the residual liquid film thickness underneath the bubbles were obtained. The second channel was investigated using cold neutron tomography, which allowed the measurement of average liquid film profiles showing the effect of spacer grids with vanes. The results were reproduced by large eddy simulation + volume of fluid. In the outlook, a novel nonadiabatic subchannel experiment is introduced that can be driven to steady-state dryout. A refrigerant is heated by a heavy water circuit, which allows the application of cold neutron tomography.

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.

Test Pattern Generation for Asynchronous Sequential Circuits Operating in Fundamental Mode (기본 모드에서 동작하는 비동기 순차 회로의 시험 벡터 생성)

  • 조경연;이재훈;민형복
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.9
    • /
    • pp.38-48
    • /
    • 1998
  • Generating test patterns for asynchronous sequential circuits remains to be a very difficult problem. There are few algorithms for this problem, and previous works cut feedback loops, and insert synchronous flip-flops in the feedback loops during ATPG. The conventional algorithms are similar to the algorithms for synchronous sequential circuits. This means that the conventional algorithms generate test patterns by modeling asynchronous sequential circuits as synchronous sequential circuits. So, test patterns generated by those algorithms nay not detect target faults when the test patterns are applied to the asynchronous sequential circuit under test. In this paper an algorithm is presented to generate test patterns for asynchronous sequential circuits. Test patterns generated by the algorithm can detect target faults for asynchronous sequential circuits with the minimal possibility of critical race problem and oscillation. And it is guaranteed that the test patterns generated by the algorithm will detect target faults.

  • PDF

The time domain testing technique of RFIC based on specifications (설계사양기반 RF 집적회로의 시간영역 테스팅 기법)

  • Han Seok-Bung;Baek Han-Suk;Kim Kang-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.5 s.347
    • /
    • pp.34-47
    • /
    • 2006
  • In this paper, a new testing technique for core components of wireless transceiver was proposed. That was, band fault models (including the information of specifications in the analogue and RF IC) and methods which can test specifications in the time domain easily by observing a variation of band fault models in the circuit output were proposed and developed. This technique had an advantage over testing technique in frequency domain because it didn't need expensive test equipments and could reduce the time required. Test technique proposed in this paper was adapted to the test of 5.25 GHz low noise amplifier and proved that this testing technique was efficient in RF IC including low noise amplifier.

Factor Associated with Injury Related to Home Mechanical Ventilation in General Ward Patients: A Retrospective Study (가정용 인공호흡기 관련 안전사고 특성 및 손상 영향 요인 분석: 상급종합병원 일반병동 환자 중심으로)

  • Kim, Hyang Sook;Choi, Mona;Yang, Yong Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.131-140
    • /
    • 2020
  • Purpose: This study aims to describe the characteristics of safety incidents and factors associated with injury for patients with Home Mechanical Ventilation (HMV) at the hospital. Methods: This is a retrospective study. Data were collected from the work log of respiratory home care nurses and the patients' electronic medical records were investigated. In order to compare group differences, independent t-test and χ2 test were used. Associated factors with injury development were identified by generalized mixed modeling analysis controlling for age and gender. Results: A total of 304 patients on HMV were included in this study, among which 129 (42.4%) experienced 352 HMV-related incidents. Mean frequency of incidents for each patient was 5.11±3.98, ranged from 1 to 15 times. In 19.0% of the incidents, injury was developed. Types of incident and persons involved in the incidents were significantly associated with the patient's injury. In the case of the safety incidents, patient's injury was significantly higher in accidents caused by respiratory circuit problems compared to those caused by problems with the ventilator operation by the medical staff (coefficient=1.25, p=.020). In addition, in the case of those involved in the safety incidents, patient's injury was significantly higher in the accident caused by the patient family members or caregivers than that caused by the medical personnel (coefficient=1.25, p=.019). Conclusion: In order to minimize injury caused by incidents in patients with HMV, hospitals need to provide systemic education to their medical staff and caregivers to enhance awareness of the importance of reporting and safety management.

Design and Fabrication of Multilayer Diplexer for Dual Band GSM/DCS Applications using Lumped Elements (집중 소자를 이용한 이중 대역 GSM/DCS용 적층형 다이플렉서의 설계 및 제작)

  • 심성훈;강종윤;최지원;윤영중;김현재;윤석진
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1090-1095
    • /
    • 2003
  • In this paper, the modeling and design of high-Q multilayer passives and multilayer diplexer for GSM/DCS applications designed and fabricated using these passives have been investigated.. To miniaturize the system, configurations of inductor and capacitor have involved a square spiral structure and a vertically-interdigitated capacitor similar to 3D interdigital structure, respectively. Multilayer diplexers for GSM/DCS applications were designed and fabricated to apply high-Q multilayer passives to practical systems, which were designed by the proposed structural and equivalent circuit model. LPF for GSM band had the passband insertion loss of less than 0.55 dB, the return loss of more than 12 dB, and the isolation level of more than 26 dB by locating attenuation pole at 1800 MHz. HPF for DCS band had the passband insertion loss of less than 0.82 dB, the return loss of more than 11 dB, and the isolation level of more than 38 dB by locating attenuation pole at 930 MHz.

A Study on Joule Heating Simulation Method to Prevent Sensitivity Current Trip of Electric Vehicle Charger (전기자동차 충전기의 누전차단기 감도 전류 Trip 방지를 위한 Joule Heating 시뮬레이션 방안연구)

  • Lee, Beoung-Kug;Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.150-159
    • /
    • 2021
  • This study aimed to prevent inconvenience to electric vehicle users caused by an interruption of charging by the earth leakage breaker trip that occurs during charging. As a field case study, it was confirmed that during the battery charger failure type, leakage current measurement experiment by vehicle type, and leakage current breaker operation experiment, the internal temperature of the charger rose to more than 60 ℃ in summer, and the earth leakage circuit breaker stopped charging by tripping at 80% of the rated sensitivity current. Through Joule heating modeling, 32A is energized at the reference temperature of 30 ℃ at the initial time t=0 (s). After t=3000 (s), the heat generated around the charging part of the earth leakage breaker increased to 32.4 ℃. The temperature and time factors correlated with the amount of heat generated according to the statistical verification tool with a correlation coefficient of 0.97. Overall, it is possible to prevent the leakage breaker sensitivity current trip due to an increase in temperature inside the charger in summer by performing a Joule heating simulation according to the material of the charging case, the arrangement of the internal wiring, and the dielectric medium when developing the charger device.

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

Comparison and Analysis for the Topology of Bladeless Wind Power Generator (블레이드리스 풍력발전기의 토폴로지에 관한 비교·분석)

  • Junhyuk Min;Sungin Jeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.4
    • /
    • pp.147-154
    • /
    • 2024
  • This study focuses on the modeling and analysis of the linear generator for a bladeless wind power generation to overcome the limitations and drawbacks of conventional wind turbines. A bladeless wind power generation system has the advantages of low land requirement for installation and maintenance cost compared to a blade wind power turbine. Nevertheless, question concerning the generator topology are not satisfying answered. The goal of the research is to compare and analyze the characteristics of horizontal and vertical structures of linear generator for bladeless wind power systems. The proposed topology will be analyzed using magnetic energy by equivalent magnetic circuit method, and then it has been compared and evaluated by finite element method. The results of this project will give elaborate information about new generator structures for wind power system and provide insights into the characteristics of bladeless wind power generation.

IPv6 Migration, OSPFv3 Routing based on IPv6, and IPv4/IPv6 Dual-Stack Networks and IPv6 Network: Modeling, and Simulation (IPv6 이관, IPv6 기반의 OSPFv3 라우팅, IPv4/IPv6 듀얼 스택 네트워크와 IPv6 네트워크: 모델링, 시뮬레이션)

  • Kim, Jeong-Su
    • The KIPS Transactions:PartC
    • /
    • v.18C no.5
    • /
    • pp.343-360
    • /
    • 2011
  • The objective of this paper is to analyze and characterize to simulate routing observations on end-to-end routing circuits and a ping experiment of a virtual network after modeling, such as IPv6 migration, an OSPFv3 routing experiment based on an IPv6 environment, and a ping experiment for IPv4/IPv6 dual-stack networks and IPv6 network for OSPFv3 routing using IPv6 planning and operations in an OPNET Modeler. IPv6 deployment based largely on the integrated wired and wireless network was one of the research tasks at hand. The previous studies' researchers recommended that future research work be done on the explicit features of both OSPFv3 and EIGRP protocols in the IPv4/IPv6 environment, and more research should be done to explore how to improve the end-to-end IPv6 performance. Also, most related work was performed with an IPv4 environment but lacked studies related to the OSPFv3 virtual network based on an end-to-end IPv6 environment. Hence, this research continues work in previous studies in analyzing IPv6 migration, an OSPFv3 routing experiment based on IPv6, and a ping experiment for IPv4/IPv6 dual-stack networks and IPv6 network for OSPFv3 routing. In the not too distant future, before enabling the default IPv6, it would help to understand network design and deployment based on an IPv6 environment through IPv6 planning and operations for the end-user perspective such as success or failure of connection on IPv6 migration, exploration of an OSPFv3 routing circuit based on an end-to-end IPv6 environment, and a ping experiment for IPv4/IPv6 dual-stack networks and IPv6 network for OSPFv3 routing. We were able to observe an optimal route for modeling of an end-to-end virtual network through simulation results as well as find what appeared to be a fast ping response time VC server to ensure Internet quality of service better than an HTTP server.