• Title/Summary/Keyword: chloride ion concentration

Search Result 300, Processing Time 0.024 seconds

Determination of Required Cover Depth of Concrete Exposed to Simultaneous Attack of Carbonation and Chloride Ion (중성화와 염소이온의 동시 복합환경에 노출된 콘크리트의 적정 피복두께의 결정)

  • 이창수;윤인석;이규동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.90-93
    • /
    • 2003
  • The most common deteriorating processes of concrete structures in the world-wide are carbonation and chloride ion. In this paper, chloride profiles of carbonated concrete is predicted to considering two layer composite model, which is based on Fick's 2nd law. From the experimental result on combined deterioration of chloride and carbonation, it was examined that high chloride concentration was built up to 3-5㎜ over depth from carbonation depth. The analytical modeling of chloride diffusion, which was based on the Fick's 2nd law of diffusion, was suggested to depict the relative influence of the carbonation depth.

  • PDF

Corrosion of Stainless Steel Pipes Buried in the Soils of Seoul Metropolitan During One Year (1년 동안 서울지역 토양에 매설된 스테인리스강의 부식)

  • Hyun, Youngmin;Kim, Heesan;Kim, Young-Ho;Jang, Hyunjung;Park, Youngbog;Choi, Youngjune
    • Corrosion Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.56-64
    • /
    • 2012
  • Factors affecting corrosion of stainless steels such as pH, oxidation and redox potential (ORP), soil resistivity, water content of soil, chloride ion concentration, bacteria activity, and corrosion potential have been investigated using soil analysis, bacterial analysis, surfacial analysis, and analysis of corrosion potentials of several stainless steels buried in 8 sites of Seoul metropolitan for one year. Corrosion potential was affected by occurrance of corrosion as well as bacteria activity but the behavior of corrosion potential with time is different depending on occurrance of corrosion and bacteria activity. The main factor affecting corrosion of stainless steels in soil is level of chloride ion concentration which is also a main factor affecting corrosion of stainless steels in chloride containing drinkable water. Furthermore, guideline of stainless steels in drinkable water is concluded to be applicable to that in soil by the results from surfacial analysis.

Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique (CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석)

  • Jeong, Jongsik;Lee, Seungjae;Lee, Jaebok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

Concentration and Size Distribution of Atmospheric Particulate Matters, Chloride, Nitrate, and Sulfate Salts in Urban Air (都市大氣중 浮遊粒子狀物質, 鹽化物, 窒酸鹽 및 黃酸鹽의 濃度와 粒經分布)

  • Sohn, Dong-Hun;Heo, Moon-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1986
  • Atmospheric particulate matter (A. P. M.) was collected and size-fractionated by an Andersen high-volume air sampler over 15 month period from Jan. 1985 to Feb. 1986 in Seoul. The concentration of chloride, nitrate and sulfate were extracted in an ultrasonic bath and were analyzed by ion chromatography. The annual arithmetical mean of A. P. M. was 128.54 $\mug/m^3$. The concentration of anions were 2.88 $\mug/m^3$ for chloride, 3.86$\mug/m^3$ for nitrate, and 25.44$\mug/m^3$ for sulfate. The content of A. P. M. was lowest in the particle size range 1.1 $\sim 3.3\mum$ and increased as the particle size increased or decreased. And the anions exhibited a seasonal variation in the isize distribution. The contents of anions were higher in winter than summer. Ther ratio of fine particles to the total particles defined by F/T for chloride, nitrate and sulfate. The F\ulcornerT of these anion generally decrease with increasing air temperature. This tendency was prevalent in the chloride and nitrate.

  • PDF

Evaluation of Testing Method for Quality Control of Chloride Diffusivity in Concrete under chloride attack environment (콘크리트 구조물의 염해 내구성능 검토를 위한 현장 품질관리 시험법 검토)

  • Kim, Hong-Sam;Cheong, Hai-Moon;Ahn, Tae-Song;Kim, Cheol-Ho;Geon, Byung-Sub
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.973-976
    • /
    • 2008
  • Recently, it is increasingly reported that the deterioration of concrete structure under marine environments is due to diffusion and penetration of chloride ions. It is very important to estimate the diffusion coefficient of chloride ion in concrete. Estimation methods of chloride diffusivity by concentration difference is time-consuming. Therefore, chloride diffusivity of concrete is mainly conducted by electrically accelerated method, which is accelerating the movement of chloride ion by potential difference. However, there has not been any proper method for field quality control to closely determine the diffusion coefficient of chloride ion through accelerated tests using potential difference. In this paper, the various test methods for determination of chloride diffusion coefficient in concrete were investigated through comparison accelerated tests. From the results of estimated diffusion coefficient of chloride ion, relationship between the ponding test and acceleration test was examined.

  • PDF

Hypsochromic Shifts in Retinochrome Absorption Spectra in the Presence of Nitrate

  • Takemori, Nobuaki;Mizukami, Taku;Tsujimoto, Kazuo
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.264-266
    • /
    • 2002
  • The absorption wavelength of the protonated retinal Schiff base can be controlled by the surrounding environment. An external anion is related to fine adjustment of the absorption wavelength. The addition of anion to retinochrome solution caused blue shift in spectra. The increase of the shift was dependent on the ion concentration. The large shift value was obtained as 20 nm at the saturated concentration of nitrate. The shift intensity for the nitrate addition exceeded that of chloride. Seemingly, it depends on the ionic strength or lyotropic character of the anion. However, neither of sulphate nor gluconate ion showed remarkable blue shift. These phenomena were accounted for with (1) delocalization of the positive charge in the conjugated polyene system, (2) ionic bonding strength between the counter ion (glutamate) and the proton, and/or (3) interaction of the added anion with the proton on Schiff base.

  • PDF

Influence of Hydrostatic Pressure on Chloride Ion Penetration of Marine Concrete (정수압이 해양콘크리트의 염화물이온 침투에 미치는 영향)

  • Kim, Gyeong-Tae;Kim, Gyu-Yong;Nam, Jeong-Soo;Lee, Bo-Kyeong;Lim, Chang-Hyuck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.78-84
    • /
    • 2019
  • The Marine concrete that located at immersion zone receives an hydrostatic pressure of 1 atm as depth of the water increased by 10 m. And it could accelerate chloride ion penetration. In this study, to evaluate the influence of hydrostatic pressure on chloride ion penetration, concrete mixed by ordinary Portland cement and Portland blast-furnace slag cement was exposed to 1 and 6 atm and substitute ocean water. As a result, the surface chloride ion concentration of the concrete under 6 atm of hydrostatic pressure increased rapidly and the water-soluble chloride ion contents was increased by depth. In addition, the concrete under 6 atm of hydrostatic pressure showed the increase of capillary pores corresponding to 5~100 nm.

Comparision of Test Methods for Estimating Chloride Ion Diffusion Coefficient in Concrete (콘크리트중의 염소이온 확산계수 추정 실험법의 비교)

  • 문한영;김홍삼;문재흠;한아름
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.787-790
    • /
    • 1999
  • To estimate durability of reinforced concrete structures located in or nearby seawater, many different kinds of accelerated tests for evaluation of chloride ion permeation in concrete were proposed. At present the only standardized test is the ASTM C 1202(RCP test). This test method is used to estimate the concrete's resistivity of the chloride penetration in concrete by using the total charges passed and sometimes used to calculate the chloride diffusion coefficients. However, this test may lead to an erroneous chloride diffusion coefficient. So this test method was compared with the modified Dhir's test and the traditional concentration diffusion test. Experimental results showed that the diffusion coefficients determined the RCP test and the PD Index gave wrongous values, but the diffusion coefficient acquired by considering a migration term was nearly the same to the CD Test.

  • PDF

Corrosion of Reinforcement and Its Effect on Structural Performance in Marine Concrete Structures

  • Yokota, Hiroshi;Kato, Ema;Iwanami, Mitsuyasu
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.297-303
    • /
    • 2007
  • This paper discusses the chloride-induced corrosion of reinforcement in marine concrete structures focusing on the variability in the progress of deterioration. Through tests and analyses of reinforced concrete slabs taken out from existing open-pile structures that have been in service for 30 to 40 years, the following topics were particularly discussed: variation in chloride ion profiles of concrete, variation in corrosion properties of reinforcement embedded in concrete, and influence of the reinforcement corrosion on the load-carrying capacity of the concrete slabs. As a result, their variability was found to be very large even in one reinforced concrete slab with almost the same conditions. It was also discussed how to determine the calculation parameters for prediction of decreasing in load-carrying capacity of concrete members with chloride-induced corrosion of reinforcement.

Spectrophotometric Determination of Ion Pair Extraction of Quaternary Amines with Metanil Yellow (Metanil Yellow에 의한 4급 Amine류의 Ino Pair 추출 흡광도 정량 (II) - Benzalkonium Chloride, Cetylpyridinium Chloride 및 Dimenhydrinate의 정량)

  • 김영수;최종환
    • YAKHAK HOEJI
    • /
    • v.35 no.1
    • /
    • pp.15-21
    • /
    • 1991
  • Quaternary amines which are widely used as medicines are nitrogen compounds. Metanil yellow(MY) and benzalkonium chloride(BKC) were mixed and added to 10ml of the buffer solution and then the solution was shaken for 5 minutes. The maximum absorption wavelength of the reaction product was 402 nm. Dichloromethane was the best extracting solvent among the several organic solvents and the most suitable pH range was 2~8. When the BKC-MY calibration curve was made in the best experimental condition, the Lambert-Beer's law was obeyed in the range of BKC concentration of 2$\times$$10^{-6}$~9$\times$$10^{-6}$M by UV spectrophotometer. This method was possible to determine quaternary ammonium salts in the pharmaceutical preparation.

  • PDF