• Title/Summary/Keyword: chemical storage tank

Search Result 81, Processing Time 0.028 seconds

The Changes of Solid, Nitrogen and Phosphorus Concentrations in Pig Slurry Stored at Various Depth of Slurry Storage Tank (돼지분뇨슬러리의 액비조내 저장깊이별 고형물 및 질소, 인의 함량분포에 관한 연구)

  • Jeong, Kwang-Hwa;Chung, Eui-Soo;Park, Chi-Ho;Kwag, Jung-Hoon;Choi, Dong-Yoon;Yoo, Yong-Hee
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • This paper describes the changes of characteristics of pig slurry according to storing depth. Most of the substances containing pollutants, such as were Management of manure and wastewater from animal confinement facilities is a critical factor for pollution control. With proper treatment processing method in both solid and liquid forms, it can be used as a fertilizer and soil conditioner. In Korea, liquid-manure handling system is very popular because its treatment and application is easy and labor saving. In the storage tank treatment, the period of fermentation process and solids-liquid separation averages six months and the supernatant liquid is being used as a fertilizer. In this study, the changes in chemical characteristics of pig slurry at varying depths of the storage tank were investigated. Results showed that the pH value of the fermented pig slurry was > 7, while the major pollutants such as BOD, SS, N and P were highest in the bottom of the tank. Therefore, the above findings proved that varying depths in the storage tank can influence the concentration of pollutants of the fermented pig slurry.

  • PDF

A Case Study on Health Impact Assessment from Petroleum Refinery Plant Operation - Human Risk Assessment due to Chemicals Inhalation - (석유정제시설 운영에 대한 건강영향평가 사례 연구 - 화학물질 흡입에 따른 인체 위해도 평가 -)

  • Myung, Nho-Il;Lee, Young-Soo;Shin, Dae-Yewn
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.259-270
    • /
    • 2010
  • We conducted human risk assessment for exposure to inhalation of chemical substances emitted from the storage tanks of petroleum refineries. To assess human risk, this study calculated chemical emissions from the external floating roofs on storage tank at petroleum refineries, as well as concentrations thereof in the ambient air using the K-SCREEN model, and then determined risk in accordance with the Reference Concentration (RfC) values and Inhalation Unit Risk criteria developed by the US Environmental Protection Agency. The results indicated that non-carcinogenic chemicals have a hazard quotient of less than 1, meaning they have an insignificant effect on human health for residential areas near the storage tanks. Among the known carcinogens, the hazard risk for benzene slightly exceeded $10^{-6}$, indicating the need for corrective reduction measures. The methodology for health impact assessment devised herein provides findings useful in decision making for policy makers and the general public with respect to construction of industrial complexes. However, the methodology proposed herein does have limitations, including discrepancy in results induced by use of U.S. data (due to the lack of usable domestic data). More systematic studies from related researchers will be needed to address these issues and produce more reliable outcomes.

Radiation Damage by the Pool Fire of LNG Storage Tank (LNG 저장 탱크의 Pool Fire에 의한 복사열 피해)

  • Sohn Jung-Hwan;Hahn Yoon-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.14-22
    • /
    • 1998
  • In this work, in order to quantitatively predict the radiation flux and propose an idea about how to reduce the radiation damage, the radiation flux caused by pool fire of an LNG storage tank has been calculated using the RISC (Risk and Industrial Safety Consultant) proposed model under various conditions. Model predictions showed that the most important parameter affecting the radiation flux by the LNG pool fire is the wind speed. The extent of radiation damage to a target from fire flame was more significant with variation of wind speed at a low wind speed than with that at a high wind speed. It was found that the radiation damage by the former is substantially reduced with planting windbreak system around the plant. Since the windbreak is most economical than any other method, it is strongly suggested to plant a tree belt in the factory surroundings, especially near by the area of gas storage facilities, linking with water cooling and fire protection systems.

  • PDF

A Study of Consequence Analysis of Physical Explosion Damage in CO2 Storage Tank (CO2 임시 저장 탱크에서의 물리적 폭발에 따른 피해영향 고찰)

  • Seo, Doo-Hyoun;Jang, Kap-Man;Lee, Jin-Han;Rhie, Kwang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.12-19
    • /
    • 2015
  • $CO_2$ is non-flammable, non-toxic gas and not cause of chemical explosion. However, various impurities and some oxides can be included in the captured $CO_2$ inevitably. While the $CO_2$ gas was temporarily stored, the pressure in a storage tank would be reached above 100bar. Therefore, the tank could occur a physical explosion due to the corrosion of vessel or uncertainty. Evaluating the intensity of explosion can be calculated by the TNT equivalent method generally used. To describe the physical explosion, it is assumed that the capacity of a $CO_2$ temporary container is about 100 tons. In this work, physical explosion damage in a $CO_2$ storage tank is estimated by using the Hopkinson's scaling law and the injury effect of human body caused by the explosion is assessed by the probit model.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

Tensile and Fatigue Strengths of STS304L for LNG Membrane Storage Tank (멤브레인 LNG 저장탱크용 STS304L의 인장 및 피로강도)

  • Na, Seong Hyeon;Kim, Yeong Gyun;Kim, Jae Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.9-14
    • /
    • 2016
  • STS304L of membrane structure has been used for a LNG storage tank and has exposed long time under the cryogenic temperature. The purposes of this study are to evaluate the mechanical properties of base and used materials for STS304L of membrane. The tensile and high cycle fatigue tests were investigated for STS304L of membrane used over 20 years at room temperature and $-162^{\circ}C$. In addition, the test of base STS304L was performed in order to compare with used material properties. The chemical composition and phase change were investigated from EDS and XRD. From results of tensile test, yield and ultimate tensile strengths of used STS304L are smaller than those of base STS304L. S-N curves were obtained from fatigue tests at both temperatures. Also, P-S-N curves were presented with statistical method recommend by JSME-S002. Fractography was conducted for analysis of fracture mechanisms.

Evaluation of the Stability of Compost Made from Food Wastes by the Fermenting Tank (음식물찌꺼기 고속발효기에 의해 처리된 퇴비의 안정성 검토)

  • Kim, Pil Joo;Chang, Ki Woon;Min, Kyoung Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.1
    • /
    • pp.35-42
    • /
    • 1995
  • To evaluate the stability of the compost made from food wastes, which were treated in the fermenting tank for 96 hours and then composted additionally in the static pile, physico-chemical properties and phytotoxicities were investigated. When food wastes were treated in the fermenting tank for 96 hours at $55{\sim}60^{\circ}C$, there is the effect of decreasing about 60% of total weight and improving the storage and the handling. However, it is impossible to make the matured compost in the fermenting tank within 2~3 days, which is the operating condition recommended by manufacturers. To use compost in the agricultural field, after treating food wastes in the fermenting tank for 2~3 days, it needs to compost additionally in the staic pile under the suitable fermenting condition over 6 weeks.

  • PDF

A HACCP model for By-products feed production

  • Dooyum, Uyeh Daniel;Woo, Seung Min;Kim, Jun Hee;Lee, Dong Hyun;Ha, Yu Shin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.136-136
    • /
    • 2017
  • By-products has been considered lately in Total Mixed Ration (TMR) as an alternative to livestock feed around the world. This is due to the high cost of using forage as feed, less expense in exploring by-products of agriculture origin and environmental concerns with their disposal. However, by-products usually contain contaminants and the production process requires fermentation using a storage and fermentation tank. Animal feed is the start point of the food safety chain in the 'farm-to-fork' model. This necessitated a study to model a protocol that will culminate to safe feed production. Hazard analysis and critical control points (HACCP), a systematic preventive approach to food safety from biological, chemical and physical hazards in production processes that can cause the finished product to be unsafe was explored. Implementation of this model provides a mechanism that ensures product safety is continuously achieved. The entire production process of By-products feed production was evaluated using HACCP wizard software. This includes the plant layout, technical standards, storage and fermentation tank cleansing method, staff assignment, safety control method, and distribution. The potential biological, chemical, and physical hazards that may exist in every step of the production process were identified, and then critical control points (CCPs) were selected. This will ensure the safety of products made from livestock that consumes by-product feed. These includes cheese, milk, beef, etc.

  • PDF

A Study on the Safety Improvement in Incineration System from the Case Study of Acrylic acid manufacturing process Accident (아크릴산 제조공정 사고사례를 통한 소각 시스템의 안전성 향상 방안)

  • Ma, Byung-Chol;Lee, Keun-Won;Im, Ji-Pyo;Kim, Young-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • Recently, waste gas incineration is increasing due to strong environmental regulatory system in Korea. These incinerating facilities are usually connected with the top of the storage tank through pipeline and incinerate off gas with the flame. Therefore, the flame originated from these facilities is likely to move back into pipeline and might cause an explosion of the storage tank. Accordingly, the purpose of this study is to suggest the preventive measures and the way to improve the safety of these incineration systems through the cause analysis of a major industrial accident occurred in a acrylic acid manufacturing process in Korea. As a result of the study, the preventive measures are suggested as follows. (1) Air or inert gas inflow facilities should be well designed to dilute flammable gases into air or inert gas sufficiently before the blower is restarted in order to prevent the explosion (2) It is needed for the detonation-type flame arresters to be installed on the top of the storage tanks. (3) In case of using the deflagration-type flame arresters, it is necessary to install a rupture disk before the arresters, or blow off the flame outside tanks by connecting the tank top and the incinerator with hood-type pipe. (4) TDR should be installed to be restarted automatically after the momentary power failure.

Carbonaceous Media for Vehicular Natural Gas Storage (자동차용 천연가스 저장을 위한 탄소매질)

  • Moon, Hee
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • Compressed natural gas (CNG) has been used as a vehicular fuel compressed at 24.8 MPa because the energy density of natural gas is extremely low compared with gasoline. Thus it has problems in both safety and cost for multiple stage compression. For these reasons the use of adsorbed natural gas (ANG) has been pursued since the storage of natural gas is possible at a relatively low pressure. The present target is to obtain media to store natural gas at 3.5 MPa as ANG that ensures the comparable energy density of CNG, giving approximately one-fourth the driving range of an equivalent volume gasoline tank. In this review, the recent development of carbon media, their characteristics, and practical applications for natural gas storage are introduced and some recommendations are also suggested.