• Title/Summary/Keyword: chemical cleaning

Search Result 524, Processing Time 0.029 seconds

Evaluation of Cleanliness and Jet Forces by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 세정제에 대한 분사력 및 세정성 평가)

  • Heo, Hyo Jung;Jung, Young An;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.401-404
    • /
    • 2010
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study. In cleaning of electronic and semiconductor equipment, a substrate(IPC-A-36) was used to test the jet forces of the agent. And according to the jet forces time of the cleaning agent, the corresponding moving distances were compared with the spray times, and for the pollutants of iron powder and dust, the cleaning efficiency was tested with the IPC-A-36 by a weight method. The moving distance increased with the spray cleaning time longer. For a spray cleaning time of 3sec, the cleaning efficiency decreased with the amount of dust and the iron powder. It was also observed that the dust was remarkably removed, compared to the iron powder.

Optimization of chemical cleaning of discarded reverse osmosis membranes for reuse

  • Jung, Minsu;Yaqub, Muhammad;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • This study optimized the chemical cleaning process of discarded RO membranes for reuse in less demanding separation processes. The effect of physicochemical parameters, including the temperature, cleaning time, pH of the cleaning solution, and addition of additives, on the cleaning process was investigated. The membrane performance was evaluated by testing the flux recovery rate and salt rejection before and after the cleaning process. High temperatures (45-50 ℃) resulted in a better flux recovery rate of 71% with more than 80% salt rejection. Equal time for acid and base cleaning 3-3 h presented a 72.43% flux recovery rate with salt rejection above 85%. During acid and base cleaning, the best results were achieved at pH values of 3.0 and 12.0, respectively. Moreover, 0.05% concentration of ethylenediaminetetraacetic acid presented 72.3% flux recovery, while 69.2% flux was achieved using sodium dodecyl sulfate with a concentration of 0.5%; both showed >80% salt rejection, indicating no damage to the active layer of the membrane. Conversely, 0.5% concentration of sodium percarbonate showed 83.1% flux recovery and 0.005% concentration of sodium hypochlorite presented 85.2% flux recovery, while a high concentration of these chemicals resulted in oxidation of the membrane that caused a reduction in salt rejection.

Effect of surfactant types in aqueous cleaning agents on their physical properties, cleaning ability and oil-water separation (수계세정제의 계면활성제 종류에 따른 물성, 세정성 및 유수분리 영향 연구)

  • Park, S. W.;Cha, A. J.;Kim, H. T.;Kim, H. S.;Bae, J. H.
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2003
  • CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. This study has been carried out as a part of development program of aqueous cleaning agent. First of all, several types of surfactants which are the most important component in aqueous cleaning agents were chosen, and the physical properties, foaming ability, cleaning ability and oil-water separation efficiency of their aqueous solutions were measured and compared for selection of proper type of surfactant in aqueous cleaning agents.

  • PDF

Preparation and Behavior of High Performance Alkaline Cleaning Agents for Steel (철강용 고성능 알칼리세정제의 제조 및 세정거동)

  • Park, Hong-Soo;Jo, Hye-Jin;Shim, Il-Woo;You, Hyuk-Jae;Kim, Myung-Soo;Hahm, Hyun-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.15-20
    • /
    • 2005
  • $Na_2CO_3$. Sodium orthosilicate (Na-OSi), Tetronix T-701 (T-701), Na-dioctyl sulfosuccinate (303C), Newpol PE-68 (PE-68), MJU-100A, and tetrasodium pyrophosphate were blended to prepare high performance alkaline cleaning agents (ACASs). The results of cleaning test with steel specimen showed that ACAS-6 ($Na_2CO_3$ 50g/Na-OSi 35g/T-701 20g/303C 18g/PE-68 17g/MJU-100A 10g/TSPP 20g/ water 180g mixture) had a good cleaning power. The cleaning power for press-rust preventing oil was 98% and 99% degreasing at 4wt%, $70^{\circ}C$ and $90^{\circ}C$, respectively ; for quenching oil, the cleaning power of ACAS-6 was 91% degreasing at 4wt% and $70^{\circ}C$. The foam heights measured immediately after foaming by Ross & Miles method and Ross & Clark method at 6wt%, $60^{\circ}C$ were 18mm and 65mm, respectively. It was concluded that ACAS-6 had a good low foaming cleaning agent.

Development of Chemical Cleaning Agents for Cleaning Indoor Water Supply Pipes (옥내급수관 세척용 화학세정제 개발 연구)

  • Lee, Jae-Hoon;Jung, Jae-Yong;Park, Yong-Bae;Bae, Jae-Heum;Woo, Dal-Sik;Sin, Hyun-Duk
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.162-171
    • /
    • 2010
  • The objective of this study is to develop cleaning agents for the indoor water supply pipe which is environmentally friendly and suitable for removing scale by using various organic acids, inorganic acids, and some additives. Among various organic acids, oxalic acid, citric acid, and malic acid showed good cleaning efficiency of iron oxides which were main components of the indoor water supply pipe scale. Several cleaning agents were formulated by adding chemical additives into these organic acids and evaluated for removal of iron oxides. In this study, it was found that nonionic surfactants were excellent for the removal of iron oxide scale among various additives. Two types of cleaning agents($F_1$, $F_2$) with comparatively high solvent power for iron oxides were formulated in this study. The cleaning agents $F_1$ made by organic acids and some additives were formulated to be safe and environmentally friendly, but seemed to have disadvantage due to their comparatively low cleaning efficiency of iron oxide than $F_2$. But, the cleaning agents $F_2$ prepared by adding inorganic acid a little to $F_1$ showed comparatively good cleaning efficiency of iron oxide and could be recommended for removing hard scale of iron oxides in the indoor water supply pipe. Thus, it is considered that the formulated cleaning agents should be selected based on the extent of scale in the indoor water supply pipe.

Cleaning Effect of Papermaking Felt with Enzymes (효소에 의한 초지용 펠트의 세척효과)

  • Yoon, Byung-Tae;Kim, Seong-Bo;Eom, Tae-Jin;Choi, Myoung-Jae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.3
    • /
    • pp.17-22
    • /
    • 2005
  • The cleaning efficiency of papermaking felt which is contaminated with fiber fines and various micro-materials was investigated and compared between the application of enzyme and commercial detergent. It was found that the cleaning efficiency by the treatment of acidic-based detergent was more efficient than that of alkaline-based one in the conventional commercial detergent. it was also observed that the treatment design of first acidic-based detergent treatment to second alkaline-based detergent procedure was better in the cleaning efficiency, compared to alkaline based-to-acidic based one. The cleaning property of felt with enzyme was resulted in good cleaning efficiency, without any addition of surfactant. Especially, the enzyme treatment under alkaline condition (pH 10) showed a better cleaning result than that under acidic condition(pH 5). The addition of nonionic surfactant to the enzyme increased the cleaning efficiency of felt and decreased the cationic demand of wastewater. These results showed more favour than the application of conventional commercial detergent.

Chemical cleaning effects on properties and separation efficiency of an RO membrane

  • Tu, Kha L.;Chivas, Allan R.;Nghiem, Long D.
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.141-160
    • /
    • 2015
  • This study aims to investigate the impacts of chemical cleaning on the performance of a reverse osmosis membrane. Chemicals used for simulating membrane cleaning include a surfactant (sodium dodecyl sulfate, SDS), a chelating agent (ethylenediaminetetraacetic acid, EDTA), and two proprietary cleaning formulations namely MC3 and MC11. The impact of sequential exposure to multiple membrane cleaning solutions was also examined. Water permeability and the rejection of boron and sodium were investigated under various water fluxes, temperatures and feedwater pH. Changes in the membrane performance were systematically explained based on the changes in the charge density, hydrophobicity and chemical structure of the membrane surface. The experimental results show that membrane cleaning can significantly alter the hydrophobicity and water permeability of the membrane; however, its impacts on the rejections of boron and sodium are marginal. Although the presence of surfactant or chelating agent may cause decreases in the rejection, solution pH is the key factor responsible for the loss of membrane separation and changes in the surface properties. The impact of solution pH on the water permeability can be reversed by applying a subsequent cleaning with the opposite pH condition. Nevertheless, the impacts of solution pH on boron and sodium rejections are irreversible in most cases.

Effectuality of Cleaning Workers' Training and Cleaning Enterprises' Chemical Health Hazard Risk Profiling

  • Suleiman, Abdulqadir M.;Svendsen, Kristin V.H.
    • Safety and Health at Work
    • /
    • v.6 no.4
    • /
    • pp.345-352
    • /
    • 2015
  • Background: Goal-oriented communication of risk of hazards is necessary in order to reduce risk of workers' exposure to chemicals. Adequate training of workers and enterprise priority setting are essential elements. Cleaning enterprises have many challenges and the existing paradigms influence the risk levels of these enterprises. Methods: Information on organization and enterprises' prioritization in training programs was gathered from cleaning enterprises. A measure of enterprises' conceptual level of importance of chemical health hazards and a model for working out the risk index (RI) indicating enterprises' conceptual risk level was established and used to categorize the enterprises. Results: In 72.3% of cases, training takes place concurrently with task performances and in 67.4% experienced workers conduct the trainings. There is disparity between employers' opinion on competence level of the workers and reality. Lower conceptual level of importance was observed for cleaning enterprises of different sizes compared with regional safety delegates and occupational hygienists. Risk index values show no difference in risk level between small and large enterprises. Conclusion: Training of cleaning workers lacks the prerequisite for suitability and effectiveness to counter risks of chemical health hazards. There is dereliction of duty by management in the sector resulting in a lack of competence among the cleaning workers. Instituting acceptable easily attainable safety competence level for cleaners will conduce to risk reduction, and enforcement of attainment of the competence level would be a positive step.

Effect of buffing on particle removal in post-Cu CMP cleaning (구리 CMP 후 연마입자 제거에 버프 세정의 효과)

  • Kim, Young-Min;Cho, Han-Chul;Jeong, Hae-Do
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1880-1884
    • /
    • 2008
  • Cleaning is required following CMP (chemical mechanical planarization) to remove particles. The minimization of particle residue is required with each successive technology generation, and the cleaning of wafers becomes more complicated. In copper damascene process for interconnection structure, it utilizes 2-steop CMP consists of Cu CMP and barrier CMP. Such a 2-steps CMP process leaves a lot of abrasive particles on the wafer surface, cleaning is required to remove abrasive particles. In this study, the buffing is performed various conditions as a cleaning process. The buffing process combined mechanical cleaning by friction between a wafer and a buffing pad and chemical cleaning by buffing solution consists of tetramethyl ammonium hydroxide (TMAH)/benzotriazole(BTA).

  • PDF

Enzymatic Cleaning of Ultrafiltration Membrane Fouled with a Semi-synthetic Type Cutting Oil

  • Chung, Kun-Yong;Lee, Jeung-Bok;Chang, Pahn-Shick
    • Korean Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.60-63
    • /
    • 2000
  • The effect of Candida rugosa and steapsin lipase cleaning was investigated for ultrafiltration polyethersulphone membrane (30,000 dalton MWCO) fouled with the semi-synthetic type cutting oil. The experimental by the water circulator. The enzyme cleaning effect was measured with respect to temperature, cleaning time and enzyme concentration. The optimum cleaning condition for the system was 25$^{\circ}C$ and 2 hour cleaning with 1,000 unites/mL steapsin solution. The pure water flux improvement by the steapsin solution cleaning was about 17% at the optimum cleaning condition.

  • PDF