• Title/Summary/Keyword: charge measurement

Search Result 564, Processing Time 0.023 seconds

The Effect of Space Charge on the PD Pattern and Dielectric Barrier Discharge under AC (교류전압에서 PD 패턴 및 유전체 장벽 방전에 미치는 공간전하의 영향)

  • Gwon, Yun-Hyeok;Hwang, Bo-Seung;Lee, Dong-Yeong;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.4
    • /
    • pp.226-231
    • /
    • 2000
  • In this paper, we present new method to analyze the space charge effect on the electrical characteristics in polymer. It is new measurement system and analysis method that have not reported yet. By using this measurement system, we make observation to space charge accumulated on the surface of polymer at AC voltage, so it is examined to verify the correlation of space charge and partial discharge(PD). In the result of experiment, it can be known that PD pattern is related more closely to space charge accumulated on the surface of polymer than in the inner part, and applied voltage in the air is ruled by this dynamic partial discharge. Also, above critical voltage, the space charge accumulated on the surface of polymer have no effect to the magnitude of PD and the applied voltage in the air. It has been known that the electric power of the dissolution system is proportioned to the frequency and the magnitude of applied voltage, but we can know by this result of the experiment that the efficiency of the dissolution is not related to the rise of voltage above critical voltage.

  • PDF

Measurement of In-plane Piezoelectric Charge Constant of Electro-Active Paper (Electro-Active Paper의 면내압전상수 측정)

  • Li, Yuanxie;Yun, Gyu-Young;Kim, Heung-Soo;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.943-946
    • /
    • 2007
  • In-plane piezoelectric charge constant of Electro-Active paper (EAPap) was investigated based on direct and converse piezoelectric effects. EAPap samples were made with cellulose film with very thin gold electrode coated on both sides of the film. To characterize direct piezoelectricity of EAPap, induced charge was measured when mechanical stress was applied to EAPap. In-plane piezoelectric charge constant was extracted from the relation between induced charge and applied in-plane normal stress. To investigate converse piezoelectricity, induced in-plane strain was measured when electric field was applied to EAPap. Piezoelectric charge constant was also extracted from the relation of induced in-plane strain and applied electric field. Piezoelectric charge constants obtained from direct and converse piezoelectricity are 31 pC/N and 178 x 10-12m/V for 45 degree sample, respectively. Measured piezoelectric charge constants of EAPap provide promising potential as a piezoelectric material.

  • PDF

Charge Injection by Needle Electrode and Reduction Properties of Streaming Electrification (침 전극을 이용한 전하 주입과 유동대전 감소 특성)

  • Kim, Yong-Woon;Lee, Duck-Chool;Kang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.108-112
    • /
    • 2000
  • The electric charge generated by flowing insulation liquid can create hazardous spark in transfer line and receiving tank etc. These electrification has generally been measured by current measurement with a ammeter connected to the receiving tank. This paper reports on the experimental result obtained by this method. As a experimental results: The injected charge value for unit volume increased in the following condition, the edge of the needle electrode was sharp, the number of needle electrode was fewer, the edge of the needle electrode was located close to the inside wall. When the charge density in the charge reducer is constant, electrode current and electrode potential by the charge injection from outside increase with increasing of oil velocity and streaming current. The electrode potential in charge reducer is made maximum value at edge point of reducer inside and minimum value at center line of charge reducer.

  • PDF

The electrochemical desorption of an eicosanethiol monolayer by electrochemical quartz crystal microbalance (EQCM을 이용한 아이코산티올 단분자막의 전기화학적 탈착)

  • Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.383-389
    • /
    • 1995
  • A new approach for the measurement of the surface coverages of monomolecular films fabricated by spontaneous adsorption of thiol compounds on gold is described. It is based on the mass change measurement with EQCM for the reductive electrochemical desorption of thiol in aqueous KOH solution. The results were compared with that of charge calculation during electrochemical desorption. The surface coverage value for eicosanethiol agrees with that obtained by charge calculation of electrochemical reduction as well as that expected from a geometrical model of the compact monolayer.

  • PDF

A Study on Measurement and Automation Method of Cylinder Head Swirl (실린더 헤드 스월 측정 및 자동화 방법에 관한 연구)

  • Lee Choong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

Development of Charger/Discharger to Test Performance for EDLC (EDLC를 위한 성능시험용 충방전기 개발)

  • Kim, Geum-Soo;Moon, Jong-Hyun;Cho, Hyun-Cheol;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.16-22
    • /
    • 2012
  • With the increase of consumption of new renewable energy, the use of Electric Double Layer Capacitor(EDLC) is being gradually widened as the next generation energy storage device. In order to expand the market of EDLC which is recently receiving a lot of attraction as a new promising area, development of a charge/discharge cycle tester to measure and test performance, is essential. Therefore, this research designed a circuit to measure capacity and internal resistance and a circuit to measure voltage maintenance properties, based on EDLC's basic charging/discharging properties so it is able to measure the state of charge and discharge at high speed. When evaluating performance characteristics, the 5[V]/100[A] prototype-EDLC charge/discharge testing system developed for this research showed ${\pm}0.1$[%] of accuracy of voltage and current measurement. It was also proved that the developed charge/discharge testing system for EDLC can be applied to the actual industry, when testing the entire system using a program produced for data monitoring and acquisition.

Analysis of Charge and Discharge Characteristics of Heavy Duty Electric Commercial Vehicle Batteries (중대형 전기 상용차 배터리의 주행중 충방전 특성 분석)

  • Song, Jingeun;Cha, Junepyo
    • Journal of Institute of Convergence Technology
    • /
    • v.11 no.1
    • /
    • pp.19-23
    • /
    • 2021
  • These days, sales of battery electric vehicles have been rapidly increasing due to the strict CO2 regulations. However, since it take too long to measure the energy economy of electric vehicles, it has been required to improve the procedure of energy economy measurement. In order to improve this problem, the present study analyzed the battery charge/discharge pattern according to the changes in battery SOC (state of charge). In general, the energy economy test is started with a battery SOC charged to 100 %. However, it was identified that when the battery is fully charged, it can actually be charged over the 100 % (e.g., 100.5 %). This can induce errors in the energy economy measurement. Therefore, the present study recommend to start the test at SOC 99.9 %. The regenerative braking was partly restricted for the SOC over 90 %. This made it difficult to estimate the overall energy economy of the electric vehicle. However, it was identified that there was no change in the battery charge/discharge characteristics under the SOC 90 %. Therefore, the energy economy test can be shortened by predicting the overall energy economy through a short mileage test.

A Study of Technology for the Accurate Measurement of the Remaining Energy in Secondary Cells

  • Kim, Seung-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.28-35
    • /
    • 2007
  • In this paper, a study was made of the technology used to measure the remaining amount of energy in secondary cells, for which demand is ever increasing. First, the standard data were stored for measurement of the remaining energy and a compare/analysis algorithm was developed. Next, hardware was designed and a prototype that can display the SOC(State Of Charge) through an LCD displayinstrument was created. The small size of the prototype allows it to be portable and its performance is within ${\pm}4$[%].

Battery State-of-Charge Estimation Algorithm Using Dynamic Terminal Voltage Measurement

  • Lee, Su-Hyeok;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.2
    • /
    • pp.126-131
    • /
    • 2015
  • When a battery is discharging, the battery's current and terminal voltage must both be measured to estimate its state of charge (SOC). If the SOC can be estimated by using only the current or voltage, hardware costs will decrease. This paper proposes an SOC estimation algorithm that needs to measure only the terminal voltage while a battery is discharging. The battery's SOC can be deduced from its open circuit voltage (OCV) through the relationship between SOC and OCV. But when the battery is discharging, it is not possible to measure the OCV due to the voltage drop in the battery's internal resistance (IRdrop). The proposed algorithm calculates OCV by estimating IRdrop using a dynamic terminal voltage measurement. This paper confirms the results of applying the algorithm in a hardware environment via algorithm binarization. To evaluate the algorithm, a Simulink battery model based on actual values was used.

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.