• Title/Summary/Keyword: characteristic degradation time

Search Result 100, Processing Time 0.036 seconds

PD classification by using ANFIS method (ANFIS 분류기법을 이용한 부분방전원의 분류)

  • Park, Seong-Hee;Yoon, Jae-Hun;Kim, Byong-Chul;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.467-467
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7^*5^*7mm^3$. Distance between needle and plane is 2 mm. Voltages applied to acceleration test are ranged 12 to 15 kV. And distribution characteristic of degraded stage is studied too. By PD detecting and data processing, discharge data was acquired from PD detecting system (Biddle instrument). The system presents statistical distribution of phase resolved. Moreover, the processing time of electrical tree is recorded to know the speed of degradation according to voltage. Finally, it's used PD classification by ANFIS method.

  • PDF

Comparing and Analysis for Classification of PD Source Generated by Electrical Tree (전기트리시 발생하는 부분방전원 분류기법 비교 분석)

  • Yoon, Jae-Hun;Kim, Byong-Chul;Kang, Seong-Hwa;Cheong, Su-Hyeon;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.464-465
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7*5*7\;mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

A Study of the Silicon Mold Surface Treatment Using CHF3 Plasma for Nano Imprint Lithography (나노임프린트 리소그래피 적용을 위한 CHF3 플라즈마를 이용한 실리콘 몰드 표면 처리 특성)

  • Kim, Young-Keun;Kim, Jae-Hyun;You, Ban-Seok;Jang, Ji-Su;Kwon, Kwang-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.10
    • /
    • pp.790-793
    • /
    • 2011
  • In this study, the surface modification for a silicon(Si) mold using $CHF_3$ inductively coupled plasma(ICP). The conditions under that plasma was treated a input ICP power 600 W, an operating gas pressure of 10 mTorr and plasma exposure time of 30 sec. The Si mold surface became hydrophobic after plasma treatment in order to $CF_x$(X= 1,2,3) polymer. However, as the de-molding process repeated, it was investigated that the contact angle of Si surface was decreased. So, we attempted to investigate the degradation mechanism of the accurate pattern transfer with increasing the count of the de-molding process using scanning electron microscope (SEM), contact angle, and x-ray photoelectron spectroscopy (XPS) analysis of Si mold surface.

Online anomaly detection algorithm based on deep support vector data description using incremental centroid update (점진적 중심 갱신을 이용한 deep support vector data description 기반의 온라인 비정상 탐지 알고리즘)

  • Lee, Kibae;Ko, Guhn Hyeok;Lee, Chong Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.2
    • /
    • pp.199-209
    • /
    • 2022
  • Typical anomaly detection algorithms are trained by using prior data. Thus the batch learning based algorithms cause inevitable performance degradation when characteristics of newly incoming normal data change over time. We propose an online anomaly detection algorithm which can consider the gradual characteristic changes of incoming normal data. The proposed algorithm based on one-class classification model includes both offline and online learning procedures. In offline learning procedure, the algorithm learns the prior data to be close to centroid of the latent space and then updates the centroid of the latent space incrementally by new incoming data. In the online learning, the algorithm continues learning by using the updated centroid. Through experiments using public underwater acoustic data, the proposed online anomaly detection algorithm takes only approximately 2 % additional learning time for the incremental centroid update and learning. Nevertheless, the proposed algorithm shows 19.10 % improvement in Area Under the receiver operating characteristic Curve (AUC) performance compared to the offline learning model when new incoming normal data comes.

Evaluation on Degradation of Heat exchanger (열교환기의 경년열화 평가)

  • Oh H.S.;Jung H.Y.;Park S.P.;Yang S.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1672-1677
    • /
    • 2005
  • The Heat exchanger to be used in the place of business that is presented an utility period comes to be long and the problem of the length of life shares by the manufacture course and using environment factor. Consequentl, it is came to the front problem of inspection, repair, exchange, the utility stopping, safety and confidence. As a result the possibility which the large safety accident can happen comes to be high. It leads mostly to the large accedent when the explosion accident happens. to keep this, The system which the regular period passes to disuse the structure is prepared but The phenomenon which Time and the strength characteristic of the material change, namely Deradation. but It can't be a preventable solution by accident to the damage. Consequentl, This research can take important role to prevent an every kind accident for domestic pressure vessel by evaluating the mechnical characteristic change of meterial, the structure safety and residual life etc.

  • PDF

Zig-zag electrode pattern for improvement of electro-optic characteristic in polymer stabilized blue phase liquid crystal cell (고분자 안정화 블루상 액정셀의 전기광학특성 향상을 위한 지그재그 형태 전극 설계)

  • Kang, Wan-Seok;Mun, Byung-June;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.183-187
    • /
    • 2011
  • The polymer-stabilized blue phase liquid crystal (BPLC) cell has advantages such as sub-millisecond response time, wide viewing angle and no rubbing process for the alignment of liquid crystals. However, high operating voltage and low kerr constant of the polymer-stabilized blue phase liquid crystal deteriorate the electro-optical characteristic of the polymer-stabilized BPLC cell. In this paper, we proposed novel zig-zag electrode in cell layout and confirmed that proposed electrode shape could reduce an over 25 percent of operating voltage for BPLC cell without degradation of tranmittance by using Kerr constant simulation.

Trade-off Characteristic between Gate Length Margin and Hot Carrier Lifetime by Considering ESD on NMOSFETs of Submicron Technology

  • Joung, Bong-Kyu;Kang, Jeong-Won;Hwang, Ho-Jung;Kim, Sang-Yong;Kwon, Oh-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Hot carrier degradation and roll off characteristics of threshold voltage ($V_{t1}$) on NMOSFETs as I/O transistor are studied as a function of Lightly Doped Drain (LDD) structures. Pocket dose and the combination of Phosphorus (P) and Arsenic (As) dose are applied to control $V_{t1}$ roll off down to the $10\%$ gate length margin. It was seen that the relationship between $V_{t1}$ roll off characteristic and substrate current depends on P dopant dose. For the first time, we found that the n-p-n transistor triggering voltage ($V_{t1}$) depends on drain current, and both $I_{t2}$ and snapback holding voltage ($V_{sp}$) depend on the substrate current by characterization with a transmission line pulse generator. Also it was found that the improved lifetime for hot carrier stress could be obtained by controlling the P dose as loosing the $V_{t1}$ roll off margin. This study suggests that the trade-off characteristic between gate length margin and channel hot carrier (CHC) lifetime in NMOSFETs should be determined by considering Electrostatic Discharge (ESD) characteristic.

Study on the characteristics and biodegradable of synthetic PLGA membrane from lactic acid and glycolic acid (젖산 및 글리콜산에서 합성된 PLGA 멤브레인의 특성과 생분해성에 관한 연구)

  • Xie, Yuying;Park, Jong-Soon;Kang, Soon-Kook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2958-2965
    • /
    • 2015
  • The PLGA(Poly lactide-co-glycolide) Copolymer have been actively applied to the medical implant material as biomaterials. PLGA membrane was able to alveoloplasty with osteotomy for favorable degradation characteristics and possibilities for sustained drug delivery. In this study, PLGA membrane was prepared using phase inversion method, and examined to optical method analysis(NMR, IR), mechanical property measurement (tearing strength) and thermal characteristic analysis(DSC). In addition, the biodegradation characteristics of the PLGA membrane filled with a PBS(Phosphate Buffered Solution) of the water bath ($60^{\circ}C$) according to the degree of surface degradation in the degradation time, the pH change of the solution and change of the mass of the membrane were measured.

A Degradation Characteristic of FRP Rebars Attacked by Combined Environmental Factors (복합환경인자에 의한 FRP 보강근의 성능저하 특성)

  • Oh, Hong Seob;Moon, Do Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.1-10
    • /
    • 2012
  • In spite of high resistant to corrosion and its strength, over the last two decades, concerns still remain about the durability of FRP materials under severe environmental and thermal exposures. In this paper, authors experimentally examine the combined degradation by thermal and chemical attacks in heterogeneous FRP rebar be made up with various fibers and resins. Five types of Carbon, Glass and Hybrid FRP rebars had manufactured by different process and surface patterns are adopted for the experiments such as weight change, interlaminar shear strength, SEM and FT-IR analysis. FRP specimens were immersed in alkaline or distilled solution up to 150 days and then thermal exposed on 60, 100, 150 and $300^{\circ}C$ for 30 minutes. From the test results, the degradation of FRP bars are influnced by the resin type and manufacturing process as well as the fiber, and ILSS of exposed FRP bar in solutions is slightly increased in initial stage and then decresed with the passing of immersed time. But, in this test, it is observed that the discrepancy of ILSS between degraded by alkaline solution and distilled water is negligible value.

관리형 매립시설 침출수 중 $SCN^-$제거를 위한 SBR 공정

  • Seong, Se-Hyeon;Hwang, Seok-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.274-277
    • /
    • 2001
  • This research was conducted as a part of continuous development of a bioprocess to treat thiocyanate($SCN^-$) in the leachate from an industrial landfill site. Detailed characteristics of the leachate, physical and chemical, was analyzed in this study. Time to reach equilibrium in $SCN^-$ degradation at different temperature, similar to the annual variation. was investigated for posssible adaptation of the bioprocess in the treatment site. Complete mineralization of $SCN^-$ to ammonia. bicarbonate and sulfate at all temperature range with except $5^{\circ}C$ trial was observed with different time elapsed to reach equilibrium. which shortened as the process of Fill-Draw proceeded. The final metabolites were mainly nitrate and sulfate. No fouling odor was detected and the settling characteristic of the biomass after the treatment was good(i.e., sludge volume index(SVI) ${\le}$80). Using MWT sludge as an inoculum showed better performance with respect to the elapsed time for treatment and sedimentation characteristics than those of using 2BET sludge.

  • PDF