• 제목/요약/키워드: characteristic degradation time

검색결과 100건 처리시간 0.029초

Electrochemical degradation of Orange G in K2SO4 and KCl medium

  • Hamous, Hanene;Khenifi, Aicha;Bouberka, Zohra;Derriche, Zoubir
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.571-578
    • /
    • 2020
  • In this work, a detailed study on the electrochemical degradation of an azo dye, Orange G is performed using a platinum electrode. Indeed, the influence of the dye concentration (50-150 mg/L), the pH of the medium and the density of the electric current is studied on the rate of discoloration, the rate of mineralization, the efficiency of the electric current and the energy consumption. The UV-visible spectra of OG plotted against the degradation time show the decrease of the intensity of the characteristic dye peaks. In an environment rich in chlorides, all peaks disappear after 15 min of degradation. However, the peaks at wavelengths of 200 and 290 nm appeared after one hour of treatment. In K2SO4, the eliminated percentages are respectively 46, 54 and 61% for wavelengths of 245, 330 and 480 nm. This suggests that the degradation mechanisms in K2SO4 and KCl environments are not the same. In the middle rich in chlorides, the eliminated percentage of OG did not seem to be affected by the concentrations increase. These results confirm the hypothesis that electrochemical oxidation process is very favorable for concentrated pollutants discharge.

Characteristic of High Voltage Aging in AC PDPs

  • Lee, Yong-Han;Kim, Oe-Dong;Ahn, Byoung-Nam;Choi, Kwang-Yeol;Kim, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.932-934
    • /
    • 2006
  • A relationship between discharge delay time and the aging method were investigated: A-Y (Address electrode - Scan electrode) aging and conventional X-Y(Common electrode - Scan electrode) aging with the variation of sustain voltage beyond self-erasing discharge. Although A-Y aging decreases discharge delay time, it has several drawbacks like non-uniformity of discharge, degradation of luminous efficiency and a color temperature. In a conventional aging condition which is carried out near the mid-margin voltage, discharge delay time is short in low voltage and high frequency condition. As an alternative to conventional voltage aging, high voltage aging is suggested which is carried out at self-erasing sustain voltage region. High voltage aging shows lower discharge delay time and fast aging speed than conventional voltage aging.

  • PDF

Position Control of Linear Actuator with Uncertain Time Delay in VDN

  • Kim, Jonghwi;Kiwon Song;Park, Gi-Sang;Park, Gi-Heung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.118.2-118
    • /
    • 2002
  • Uncertain time delay happens when the process reads the sensor data and sends the control input to the plant located at a remote site in distributed control system. As in the case of data network using TCP/IP, VDN that integrates both device network and data network has uncertain tim e delay. Uncertain time delay can cause degradation in stability of distributed control system based on VDN. This paper investigates the transmission characteristic of VDN and suggests a control scheme based on the Smith's predictor to minimize the effect of uncertain time delay. The validity of the proposed control scheme is demonstrated with tracking position control of experiments.

  • PDF

RTV 실리콘 고무 코팅재의 표면전하 축적이 발수성에 미치는 영향 (Effect of Accumulated charges on Surface Hydrophobicity of RTV Silicone Rubber)

  • 연복희;허창수;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2001
  • In this paper, we evaluated the effect of accumulated charges on hydrophobicity of room temperature vulcanized(RTV) silicone rubber, which could improve the contamination performance of porcelain insulators, with uv radiation time. Outdoor insulating material could be charged by the corona discharge on field intensified area of insulator and discharge between the water drops. In addition, we performed the accelerated uv radiation on samples and investigated the change of charging decay with time. In this results, it is found that silica-like structure on the surface of RTV silicone rubber was formed by uv treatments and this layer have the characteristic of retaining the charges on surface for a long time. These charges have effects on its hydrophobicity and so adversely effects on contamination performance. Based on our results, we discussed the other degradation mechanism with well known ones.

  • PDF

An improved Maxwell creep model for salt rock

  • Wang, Jun-Bao;Liu, Xin-Rong;Song, Zhan-Ping;Shao, Zhu-Shan
    • Geomechanics and Engineering
    • /
    • 제9권4호
    • /
    • pp.499-511
    • /
    • 2015
  • The creep property of salt rock significantly influences the long-term stability of the salt rock underground storage. Triaxial creep tests were performed to investigate the creep behavior of salt rock. The test results indicate that the creep of salt rock has a nonlinear characteristic, which is related to stress level and creep time. The higher the stress level, the longer the creep time, the more obvious the nonlinear characteristic will be. The elastic modulus of salt rock decreases with the prolonged creep time, which shows that the creep damage is produced for the gradual expansion of internal cracks, defects, etc., causing degradation of mechanical properties; meanwhile, the creep rate of salt rock also decreases with the prolonged creep time in the primary creep stage, which indicates that the mechanical properties of salt rock are hardened and strengthened. That is to say, damage and hardening exist simultaneously during the creep of salt rock. Both the damage effect and the hardening effect are considered, an improved Maxwell creep model is proposed by connecting an elastic body softened over time with a viscosity body hardened over time in series, and the creep equation of which is deduced. Creep test data of salt rock are used to evaluate the reasonability and applicability of the improved Maxwell model. The fitting curves are in excellent agreement with the creep test data, and compared with the classical Burgers model, the improved Maxwell model is able to precisely predict the long-term creep deformation of salt rock, illustrating our model can perfectly describe the creep property of salt rock.

가상 디바이스 네트워크상에서 불확실한 시간지연을 갖는 실시간 분산제어를 이용한 예지보전에 관한 연구 (Real-time Distributed Control in Virtual Device Network with Uncertain Time Delay for Predictive Maintenance (PM))

  • Kiwon Song;Gi-Heung Choi
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.154-160
    • /
    • 2003
  • 원격지에 위치한 분산제어 시스템과 센서 데이터 또는 제어 명령을 주고받을 때에는 불확실한 시간지연이 발생한다. TCP/IP 프로토콜을 이용한 데이터 네트워크와 마찬가지로 데이터 네트워크와 디바이스 네트워크를 결합한 가상 디자이스 네트워크도 불확실한 시간지연이 내재되어 있다. 이러한 시간지연은 분산제어시스템의 성능을 저하시키고 불안전성을 야기하는 원인이 된다. 본 논문에서는 이러한 네트워크상에 내재하는 시간지연을 평가하고 부정적인 효과를 최소화하기 위하여 Smith Predictor를 적용하였다. 제안된 제어 알고리즘은 실시간 서보제어를 통하여 효과를 입증하였으며 가상 디바이스 네트워크 개념에 근거한 분산제어 시스템을 이용하여 실시간 예지보전을 수행할 때 효과가 있음을 제시하였다.

부스닥트용 내열성 에폭시 분체도료의 절연 및 열화 특성 연구 (A Study on the Insulation and Electrical Degradation Properties of Heat Resistance Epoxy Powder for Busduct)

  • 강철화;박지군;박종규;주현돈;김현희
    • 한국전기전자재료학회논문지
    • /
    • 제26권9호
    • /
    • pp.662-668
    • /
    • 2013
  • Reported here are results of the mechanical and electrical properties of both of intact and thermally degraded epoxy-coated copper busducts that are made by fluidized bed process. To elucidate and compare the properties mentioned above, electrical breakdown by thermal and water aging, v-t characteristic, bending test, impact test and cross cut test are carried out. Although the performance of electrical and mechanical properties are gradually decreased in increasing the severe conditions such as temperature, aging time, and so forth, sample C has a better performance in both mechanical and electrical properties.

수산화나트륨의 노출 강도가 PVDF 분리막 성능에 미치는 영향 (Effects of exposure intensity of sodium hydroxide on PVDF membrane performance)

  • 이용수;강하영;김우하;이창규;김종오
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.453-460
    • /
    • 2018
  • The impact of sodium hydroxide, which is one of chemicals of clean in place (CIP) for removing membrane fouling, on the PVDF membrane is reviewed with respect to physical/chemical structural change, the permeability affected therefrom. Based on the cleaning concentration applied in membrane water treatment facilities, 10% of accumulated defluorination was confirmed up to 166g.hr/L which reflects the exposure time. However, membrane resistance was confirmed to be reduced by about 10%. Through FT-IR and EDS analysis, reduction of F and change of are confirmed as factors that affect the permeability of membrane. Membrane resistance, which affects permeability, is affected by loss of additives for hydrophilicity, rather than defluorination of PVDF material. Therefore, in order to check membrane degradation degree, an accelerated test by NaOH was carried out, loss of additives was confirmed, and then PVDF inherent characteristic was observed.

인가전압에 따른 모의변압기의 HFPD 특성분석 (HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage)

  • 김덕근;임영삼;임장섭;문채주;이진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

웨이브렛 근사계수 기반의 분포특성을 이용한 잡음 제거 방법에 관한 연구 (A Study on Noise Reduction Method using Wavelet Approximation Coefficient-based Distribution Characteristics)

  • 배상범;김남호
    • 한국정보통신학회논문지
    • /
    • 제14권2호
    • /
    • pp.513-520
    • /
    • 2010
  • 잡음에 의한 열화현상은 디지털화된 데이터의 인지도를 저하시킨다. 따라서 신호의 에지 성분을 보존함과 동시에 잡음을 제거하기 위한 시간영역과 주파수영역의 다양한 방법들이 사용되고 있다. 본 논문에서는 신호에 중첩된 복합적인 잡음을 감소시키기 위해, 웨이브렛 근사 계수를 이용한 새로운 잡음 제거 알고리즘을 제안하였다. 제안된 알고리즘에서는 신호의 에지와 잡음에 대한 구분 성능을 향상시키기 위해, 웨이브렛 근사계수의 누적으로부터 얻어지는 오차함수의 분포특성을 이용하였다.