• 제목/요약/키워드: changwon

검색결과 5,887건 처리시간 0.031초

고기능성 세라믹 주형 및 중자 제작을 위한 3원계 무기 바인더 시스템 개발 (Development of Ternary Inorganic Binder System for Manufacturing High-Functional Ceramic Molds and Core)

  • 박혜영;조근호;최현희;김봉구;김은희;양승철;정연길
    • 한국재료학회지
    • /
    • 제32권12호
    • /
    • pp.538-544
    • /
    • 2022
  • In existing ceramic mold manufacturing processes, inorganic binder systems (Si-Na, two-component system) are applied to ensure the effective firing strength of the ceramic mold and core. These inorganic binder systems makes it possible to manufacture a ceramic mold and core with high dimensional stability and effective strength. However, as in general sand casting processes, when molten metal is injected at room temperature, there is a limit to the production of thin or complex castings due to reduced fluidity caused by the rapid cooling of the molten metal. In addition, because sodium silicate generated through the vitrification reaction of the inorganic binder is converted into a liquid phase at a temperature of 1,000 ℃. or higher, it is somewhat difficult to manufacture parts through high-temperature casting. Therefore, in this study, a high-strength ceramic mold and core test piece with effective strength at high temperature was produced by applying a Si-Na-Ti three-component inorganic binder. The starting particles were coated with binary and ternary inorganic binders and mixed with an organic binder to prepare a molded body, and then heat-treated at 1,000/1,350/1,500 ℃ to prepare a fired body. In the sample where the two-component inorganic binder was applied, the glass was liquefied at a temperature of 1,000 ℃ or higher, and the strength decreased. However, the firing strength of the ceramic mold sample containing the three-component inorganic binder was improved, and it was confirmed that it was possible to manufacture a ceramic mold and core via high temperature casting.

독뫼 감 농업의 GIAHS 등재 및 보전을 위한 4개국 과수 지역 GIAHS의 동적 계획 비교 및 분석 (Comparison and Analysis of Action Plans of GIAHS in the Four Countries of Orchards for GIAHS Listing and Conservation of Dokmoe Persimmon System)

  • 안성규;전유신;김영진;서혜영;김종핵;이완석
    • 농촌계획
    • /
    • 제30권2호
    • /
    • pp.35-50
    • /
    • 2024
  • Dokmoe persimmon system in Changwon, designated as a Korea National Important Agricultural Heritage System is a unique agricultural heritage system, is a farming system carried out in the sloping semi-mountainous terrain of the low hills downstream of the Nagdong River. In this study, we analyzed the proposal submitted for registration by the orchard region GIAHS and analyzed the regional characteristics, agricultural characteristics, and threats to heritage conservation of Dokmoe persimmon system. Dokmoe persimmon system is located in a large city, so the threat of development was analyzed as a threat factor differentiated from other regions, and the development of the processing industry was analyzed as a common initiative for GIAHS in the orchard area. Based on this, we established a action plan for heritage conservation. The action plan consists of 4 main criteria, 6 plans, and 14 initiatives. Research on Dokmoe persimmon farming is now at the starting point, and this study will be able to contribute to registration of Dokmo persimmon system in GIAHS.

Role of Neurosurgeons in the Treatment of Acute Ischemic Stroke in the Emergency Room

  • Sang Hyuk, Lee;Taek Min, Nam;Ji Hwan, Jang;Young Zoon, Kim;Kyu Hong, Kim;Kyeong Hwa, Ryu;Do-Hyung, Kim;Byung Soo, Kwan;Hyungon, Lee;Seung Hwan, Kim
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권1호
    • /
    • pp.24-32
    • /
    • 2023
  • Objective : With the recent increase in mechanical thrombectomy (MT) for acute ischemic stroke (AIS), the role of neurosurgeons in AIS treatment has become increasingly important. This study aimed to assess the outcomes of patients with AIS treated by neurosurgeons and neurologists in the emergency room (ER) of a tertiary hospital in South Korea. Methods : From January 2020 to June 2021, 536 patients with AIS within 24 hours of symptom onset were admitted to our hospital via the ER. Based on the type of doctors who provided initial care for AIS in the ER, patients were divided into two groups : (a) neurosurgeon group (n=119, 22.2%) and (b) neurologist group (n=417, 77.8%). Results : Intravenous tissue plasminogen activator (tPA) was administered in 82 (15.3%) of 536 patients (n=17 [14.3%] in the neurosurgeon group and n=65 [15.6%] in the neurologist group). The door-to-tPA time was not significantly different between both groups (median, 53 minutes; interquartile range [IQR], 45-58 vs. median, 54 minutes; IQR, 46-74; p=0.372). MT was performed in 69 patients (12.9%) (n=25, 36.2% in the neurosurgeon group and n=44, 63.8% in the neurologist group). The neurosurgeon group achieved a shorter door-to-puncture time than the neurologist group (median, 115 minutes; IQR, 107-151 vs. median, 162 minutes; IQR, 117-189; p=0.049). Good clinical outcomes (3-month modified Rankin Scale 0-2) did not differ significantly between the two groups (96/119 [80.7%] vs. 322/417 [77.2%], p=0.454). Conclusion : The neurosurgeon group showed similar door-to-treatment time and clinical outcomes to the neurologist group in patients with AIS in the ER. This study suggests that neurosurgeons have comparable abilities to care for patients with AIS in the ER.

Conversion to Veno-arteriovenous Extracorporeal Membrane Oxygenation for Differential Hypoxia

  • Ho Jeong Cha;Jong Woo Kim;Dong Hoon Kang;Seong Ho Moon;Sung Hwan Kim;Jae Jun Jung;Jun Ho Yang;Joung Hun Byun
    • Journal of Chest Surgery
    • /
    • 제56권4호
    • /
    • pp.274-281
    • /
    • 2023
  • Background: Patients who require initial venoarterial extracorporeal membrane oxygenation (VA ECMO) support may need to undergo veno-arteriovenous ECMO (VAV ECMO) conversion. However, there are no definitive criteria for conversion to VAV ECMO. We report 9 cases of VAV ECMO at Gyeongsang National University Changwon Hospital, Gyeongsang National University College of Medicine. Methods: Of 158 patients who received ECMO support between January 2017 and June 2019, 82 were supported by initial VA ECMO. We retrospectively reviewed the medical records of 9 patients (7 men and 2 women; age, 53.1±19.4 years) who had differential hypoxia and required VAV ECMO support. Percutaneous transaortic catheter venting was used to detect the differential hypoxia. Results: Among the 82 patients who received VA ECMO support, 9 (10.9%) had differential hypoxia and required conversion to VAV ECMO support. The mean time from VA ECMO support to VAV ECMO support and the mean duration of the VAV support were 2.1±2.2 days and 1.9±1.5 days, respectively. The average peak inspiratory pressure before and after VAV ECMO application was 23.89±3.95 cmH2O and 20.67±5.72 cmH2O, respectively, decreasing by an average of 3.2±3.5 cmH2O (p=0.040). The PaO2/FiO2 ratio was kept below 100 mm Hg in survivors and non-survivors for 116±65.4 and 250±124.9 minutes, respectively (p=0.016). Six patients underwent extracorporeal cardiopulmonary resuscitation, of whom 4 survived (67%). The overall survival rate of patients who underwent conversion from VA ECMO to VAV ECMO was approximately 56%. Conclusion: Rapid detection of differential hypoxia is required when VA ECMO is applied, and efficient conversion to VAV ECMO may be critical for patient survival.

Association between shift work and serum homocysteine level in female electronic manufacturing services workers

  • Jae Won Lim;Chan Woo Kim;Hyoung Ouk Park;Eui Yup Chung;Changho Chae;JunSeok Son;Young Hoo Shin;Seung Hyun Park;Sang Moon Choi
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.4.1-4.11
    • /
    • 2023
  • Background: Shift work has been shown to increase the risk of cardiovascular disease (CVD) based on several evidences. The classic risk factors of CVD include age, hypertension, smoking, obesity and diabetes. Recently, the serum homocysteine level has been reported to be a valuable indicator of CVD risk. This study aimed to determine the variation in serum homocysteine level as a cardiovascular risk indicator among female workers according to shift work. Methods: The data of regular health examination of workers at an electronic manufacturing services company in Yeongnam region, South Korea in 2019 were examined in this study. The investigation was based on a cross-sectional study conducted on 697 female workers (199 day workers and 498 shift workers). The sociodemographic and biochemical characteristics were compared between day workers and shift workers. Through a logistic regression analysis, the odds ratio (OR) of the increased serum homocysteine level in relation to shift work was determined. Results: Compared to female day workers, female shift workers showed significantly higher level of serum homocysteine (8.85 ± 2.16 vs. 9.42 ± 2.04 μmol/mL; p = 0.001). The OR of day workers against shift workers was 1.81 (95% confidence interval [CI]: 1.25-2.63). With the adjustment of variables that may influence the level of serum homocysteine, the adjusted OR was 1.68 (95% CI: 1.09-2.60). Conclusions: The serum homocysteine level was significantly higher in shift workers than in day workers. It is thus likely to be a useful predictor of CVD in shift workers.

Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI

  • Bo Hwa Choi;Hye Jin Baek;Ji Young Ha;Kyeong Hwa Ryu;Jin Il Moon;Sung Eun Park;Kyungsoo Bae;Kyung Nyeo Jeon;Eun Jung Jung
    • Korean Journal of Radiology
    • /
    • 제21권9호
    • /
    • pp.1036-1044
    • /
    • 2020
  • Objective: To investigate the clinical feasibility of synthetic diffusion-weighted imaging (sDWI) at different b-values in patients with breast cancer by assessing the diagnostic image quality and the quantitative measurements compared with conventional diffusion-weighted imaging (cDWI). Materials and Methods: Fifty patients with breast cancer were assessed using cDWI at b-values of 800 and 1500 s/mm2 (cDWI800 and cDWI1500) and sDWI at b-values of 1000 and 1500 s/mm2 (sDWI1000 and sDWI1500). Qualitative analysis (normal glandular tissue suppression, overall image quality, and lesion conspicuity) was performed using a 4-point Likert-scale for all DWI sets and the cancer detection rate (CDR) was calculated. We also evaluated cancer-to-parenchyma contrast ratios for each DWI set in 45 patients with the lesion identified on any of the DWI sets. Statistical comparisons were performed using Friedman test, one-way analysis of variance, and Cochran's Q test. Results: All parameters of qualitative analysis, cancer-to-parenchyma contrast ratios, and CDR increased with increasing b-values, regardless of the type of imaging (synthetic or conventional) (p < 0.001). Additionally, sDWI1500 provided better lesion conspicuity than cDWI1500 (3.52 ± 0.92 vs. 3.39 ± 0.90, p < 0.05). Although cDWI1500 showed better normal glandular tissue suppression and overall image quality than sDWI1500 (3.66 ± 0.78 and 3.73 ± 0.62 vs. 3.32 ± 0.90 and 3.35 ± 0.81, respectively; p < 0.05), there was no significant difference in their CDR (90.0%). Cancer-to-parenchyma contrast ratios were greater in sDWI1500 than in cDWI1500 (0.63 ± 0.17 vs. 0.55 ± 0.18, p < 0.001). Conclusion: sDWI1500 can be feasible for evaluating breast cancers in clinical practice. It provides higher tumor conspicuity, better cancer-to-parenchyma contrast ratio, and comparable CDR when compared with cDWI1500.