• 제목/요약/키워드: change point analysis

검색결과 1,293건 처리시간 0.026초

밸브 구동용 고속 리니어 액추에이터 (A Design of High-Speed Linear Actuator for Valve)

  • 성백주
    • 유공압시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 2011
  • The main design factors which effect on operating speed of linear actuator for valve operation are mass of plunger, electromagnetic motive force, inductance, and return spring, and these factors are not independent but related with each other in view point of design and electromagnetic theory. It is impossible to increase the operating speed by only change the value of any one design factor. The change of any one value results in change of any value related it in various design factors. This paper presents a speed increasing method of linear actuator using a solenoid design method by some governing equations which are composed of electromagnetic theory and empirical knowledge and permanent magnets as assistant material, and proved the propriety by experiments.

치매환자(患者) 32례(例)에 대(對)한 임상적(臨床的) 고찰(考察) (The Clinical Analysis on 32 Cases of Dementia)

  • 이영욱;강화정;조명래;진천식;홍석;김종석
    • 대한한방내과학회지
    • /
    • 제19권1호
    • /
    • pp.301-317
    • /
    • 1998
  • A clinical analysis was carried out for 32 patients who were treated in Dept. of Dong-shin Oriental Medicine Hospital from 10st January to 16st May in 1998 and ruled out as dememtia. The results were summarized as follows. 1. In the distribution of sex, female was more than male. And the age of seventies(17 cases, 53.125%) was highest in the frequency of age. 2. In the distribution of having history of drinking and smoking were each 4 cases(12.5%) and 7 cases(21.875%). 3. In the distribution of seasons, the ratio of spring and winter were each 16 cases(50.0%), 15 cases(46.875%), that of summer and fall were comparatively low. 4. In the period from onset to admission, the period within a week had 20 cases(62.5%) as top, and the most period of treatment was 2 and 3 weeks(28.125%). 5. The number of cases that had preceding disease was 35 cases(71.875%), a major portion of preceding diseases were hypertension, diabetes mellitus, stroke. 6. The most common symptom was disorientation(78.125%), and the next common symptom was motor desability(71.875%), and memory disturbance, verbal disturbance was each 59.375 and 47.1%. 7. In the distribution of the CT scan films, 15 cases(46.875%) showed cerebral infarction and that of another 5cases (15.625%) showed cerebral hemorrhage, that of another 2 cases(6.25%) showed brain atrophy. 8. In the lipid density of blood, T-Cholesterol, TG, HDL-Cholesterol, LDL- Cholesterol was within normal limit. 9. In the MMSE-K, the most score was from 16 point to 20 point, and second only was from 11 point to 15 point, and the next was from 6 point to 10 point. 10. In the Ischemic score, 20 cases(62.5%) was diagnosed as brain vascular type dementia, and mixed type dementia was 9 cases(28.125%), Alzheimer type dementia was 3 cases(9.375%). 11. The most used recipes were a sort of recipes to activate of flow the vital energy and the blood, to remove the phlegm(41 cases 33.9%), especially DODAMHOALHEL TANG (12 cases, 9.9%), ANSINCHUNGNOITANG (8 case, 6.6%) was the most used recipe. 12. In the judgement of efficacy, 17 cases(53.125%) showed excellent efficacy, 10 cases(31.25%) showed good efficacy, 5 cases(15.625%) showed no change and that according to MMSE-K, 4 case(18.18%) showed excellent efficacy, 15 cases(68.18%) showed good efficacy, 15 cases(68.18%) showed no change.

  • PDF

일부 보건계열 대학생들의 심폐소생술 교육 전·후 비교 및 교육 후 수행능력에 미치는 영향 (A Change of the ability of CPR After educations for Some Health College Students and the factors Effects CPR Performance)

  • 박상섭;박대성;고종현;김영아;박재성
    • 한국응급구조학회지
    • /
    • 제12권3호
    • /
    • pp.17-26
    • /
    • 2008
  • Purpose : This study aimed to make comparison before and after CPR training for health college students (departments of visual optics, occupational therapy, and health welfare administration). The questionnaire consisted of self-efficacy, knowledge, and attitudes toward CPR affect performance ability. Through this study, the researchers tried to provide basic data in developing of cardiopulmonary resuscitation training programs and training methods for health college students. Methods : This study was applied to 83 health college students (departments of visual optics, occupational therapy, and health welfare administration) in G Province. Data were collected from September 22 to October 9, 2008. Analysis was performed by using SPSS WIN 12.0 Version program. Frequency analysis, t-test, ANOVA, and Pearson's correlation coefficients were used. Statistical significance was based on p < .05. Results : 1. There was an increase with(${\rightarrow}$ in) 1.69 point before education and 3.01 after education of artificial ventilation(p < .001). There was an increase in 1.46 point before education and 3.24 after education of airway(p < .001). There was an increase in 1.54 point before education and 2.84 after education of chest compression location(p < .001). There was an increase in 1.97 point before education and 3.13 after education of chest compression(p < .001). 2. The difference between self-efficacy, knowledge, and attitude before and after CPR education, the self-efficacy increased from 2.08 point before education(p < .001 to 3.18 point after education. Knowledge increased from 2.09 point before education(p < .001) to 3.28 point after education. Attitude increased from 1.75 point before education(p < .001 to 3.05 point after education. 3. The correlation between self-efficacy, knowledge, and attitude toward CPR), was not changed before education. After education, knowledge showed quantitative correlation(r = .219, p < .05) with attitude. 4. In regression analysis with the aim of examining influence of self-efficacy, knowledge, and attitude upon performance ability, the effect wasn't given to performance ability before education. After education, the self-efficacy was indicated to have significant effect on performance ability(p < .05).

  • PDF

현장계측과 수치해석에 의한 흙막이구조물의 거동 비교분석 (A Study on Behavior of the Earth Retaining Structure by Field Measurement and Numerical Analysis)

  • Wo, Jongtae
    • 한국재난정보학회 논문집
    • /
    • 제13권3호
    • /
    • pp.286-295
    • /
    • 2017
  • 본 연구는 경사계에 의한 지중수평변위 계측값을 중심으로 수치해석에 적용하기 위한 지반 반력계수를 다양한 이론 및 경험식으로 산출하여 비교하였다. 산정된 지반반력계수의 변화에 따라 벽체 최상단에서는 벽체변위의 최소값과 최대값의 차이가 6.80배로 크게 났으나, 최대 변위점에서는 차이는 거의 없는 1.06배로 나타나 지반반력계수의 증분에 비해 변위의 차이는 작으며 전체적으로 비슷한 값을 나타내었다. 또한 최대변위 발생점에서의 변위를 수치해석한 결과와 계측치로 비교한 결과 변위형상은 비슷하게 나타났다.

도시 외부공간의 시각적 변화에 대한 인지 및 선호도 분석에 관한 연구 (A Study on the Analysis of Cognition and Preference for the Visual Changes of Urban Exterior Space)

  • 이선화;김유길
    • 한국조경학회지
    • /
    • 제27권3호
    • /
    • pp.58-68
    • /
    • 1999
  • Purpose of this thesis is to find out the relationship among the amount of change and the visual cognition, and the visual preference which people like and can feel. Through the investigation of relationships between the amount of change, which indicates the degree of visual variation and the visual preference, the amount of change and the visual cognition, and the visual preference and the visual cognition, basic design data will be supplied, which can satisfy users' desire as much as possible in the most economic way. In order to investigate the relationship between the visually produced the amount of change and preferences, graphic simulation, in which variables other than the visual change are controlled, has been proceeded. Graphic factors of the visual change in the cyber exterior space are determined on the point of location (base plane, vertical plane, overhead plane), shape, size and color. As for the relationship between the amount of change and the preference, only the size is effective. since preferences on the location, shape and color are individual preferences, no common trend can be found. Therefore, we cannot say that which shape or color is better, Since the location, shape and color are qualitative change and the size is the quantitative change, the size can be the measurable change quantity. The relationship between the amount of change of size and the degree of preference is found to be inverse U-shape, i.e., as the amount of change of size increases the degree of preference first increases and, after a certain level, decreases. The same result has been obtained in photo simulation.

  • PDF

온실가스 시료 보관시간에 따른 CH4 농도 변화 (Temporal Variability of CH4 Gas Concentration Collected in Sampling Bag)

  • 홍윤정;조창상;강성민;윤현기;전의찬
    • 한국기후변화학회지
    • /
    • 제7권4호
    • /
    • pp.477-484
    • /
    • 2016
  • In general, $CH_4$ concentrations generated in combustion facilities are known to be ppm units. In most cases, $CH_4$ samples are collected in Tedlar bags and transported to laboratories for analysis. Considering this fact, in the present study, an attempt was made to find out how long samples can be stored in cases where they are kept in bags and transported as a preliminary study for sampling. According to the results of the experiment using simulated gases (1 ppm, 5 ppm, 10 ppm) in Tedlar bag, $CH_4$ was safe up to 240 hr which is the full time. In the case of simulated gases are containing 4 kind gases ($N_2$, $CO_2$, $CH_4$, and $N_2O$). Field samples (samples of obtained by collecting combustion facilities' exhaust gases) are known to contain highly reactive substances (for example NOx, SOx, and VOCs) and may affect each other. In the present study, one site sample was secured from each of a bituminous coal combustion facility and an LNG combustion facility and whether the concentrations of $CH_4$ gas would change over time (24 hr, 96 hr, 144 hr, 192 hr) was checked. Since site samples could not be analyzed on the day of collection, an experiment was started 24 hr after the time point of sampling to analyze the samples. As with the results of analysis of the simulated gas (240 hr), the results of analysis using the site sample indicated that it could be stored for the full study period 192 hr. Therefore, it was judged that if 192 hr would be taken after sampling before the sample would be analyzed, the concentration value should be reliable.

근임계 환경으로 분사되는 제트의 임계점이 상변화에 미치는 영향 (Influence of Critical Point of Jet Injected into Near-Critical Environment on Phase Change)

  • 윤태경;신동수;손민;신봉철;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.475-481
    • /
    • 2017
  • 본 실험에서는 추진기관 연료의 주 성분으로 사용되는 액체 탄화수소 화합물의 초임계 분사 거동 특성을 분석하기 위해서 고속카메라 이미지를 활용한 실험을 수행하였다. 케로신의 구성성분 중 임계점의 차이가 있는 Decane과 Methylcyclohexane (MCH)를 실험 유체로 선정하였으며, 분석을 위해 Shadowgraphy 기법을 사용하였다. 제트 분사 시 임계온도 조건 하에서 각 유체의 환산압력에 따라 케이스를 나누었다. 아임계 조건의 동일한 인젝터 초기상태에서 기화가 발생하기까지 온도변화량의 차이에 따라 Decane과 MCH는 서로 다른 거동을 보였다. 하지만 초임계 조건에서는 같은 온도변화량이 필요하더라도 임계점 부근에서는 증발엔탈피가 0에 가까워져 기화과정이 아닌 초임계 유체로의 상변화가 일어나고 급격한 밀도변화가 없어 Decane과 MCH 모두 원기둥 형상의 액주가 관측되었다.

  • PDF

하악전돌증환자의 악교정수술후 안면측모 변화에 관한 두부방사선 계측학적 연구 (A CEPHALOMETRIC STUDY OF PROFILE CHANGES FOLLOWING ORTHOGNATHIC SURGERY IN PATIENTS WITH MANDIBULAR PROGNATHISM)

  • 이형식;박영철
    • 대한치과교정학회지
    • /
    • 제17권2호
    • /
    • pp.299-310
    • /
    • 1987
  • The purpose of this study was to examine soft tissue and hardtissue changes following orthognathic surgery in patients with mandibular prognathism lateral cephalometric films were obtained immediate before surgery, 48 hours following surgery, and 6 months following surgery. 18 patients were selected (10 men, and 6 women) for this study, who had received orthognathic surgery. Statistical analysis for the each time interval differences were performed with the SPSS package The results were as follows, *In the cases of mandibular sagittal split osteotomy 1 LI point was moved backward (average 7.55mm) 48 hours following surgery. 6 months later, it was returned forward (average 1.1mm) Relapse rate was 14.6% 2 Pog was moved backward (average 8.3mm) 48 hours following surgery The ratio of horizontal change of soft tissue to hard tissue at pog is 0.95 1 *In the cases of maxillary Le-Fort I osteotomy & mandibular sagittal split osteotomy. 3. A point was moved forward (average 3.31mm) 48 hours following surgery. 6 months later, it was returned backward (average 0.31) Relapse rate was 9 4% 4 6 months later, the ratio of facial convexity angle change of soft tissue to hard tissue is 0.63 1.

  • PDF

Mesospheric Temperatures over Apache Point Observatory (32°N, 105°W) Derived from Sloan Digital Sky Survey Spectra

  • Kim, Gawon;Kim, Yong Ha;Lee, Young Sun
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권2호
    • /
    • pp.119-125
    • /
    • 2017
  • We retrieved rotational temperatures from emission lines of the OH airglow (8-3) band in the sky spectra of the Sloan digital sky survey (SDSS) for the period 2000-2014, as part of the astronomical observation project conducted at the Apache Point observatory ($32^{\circ}N$, $105^{\circ}W$). The SDSS temperatures show a typical seasonal variation of mesospheric temperature: low in summer and high in winter. We find that the temperatures respond to solar activity by as much as $1.2K{\pm}0.8K$ per 100 solar flux units, which is consistent with other studies in mid-latitude regions. After the seasonal variation and solar response were subtracted, the SDSS temperature is fairly constant over the 15 year period, unlike cooling trends suggested by some studies. This temperature analysis using SDSS spectra is a unique contribution to the global monitoring of climate change because the SDSS project was established for astronomical purposes and is independent from climate studies. The SDSS temperatures are also compared with mesospheric temperatures measured by the microwave limb sounder (MLS) instrument on board the Aura satellite and the differences are discussed.

CFD 해석을 이용한 실내 온도 최적 측정 위치 선정 방법 (Optimal Measuring Point Selection Method of Indoor Temperature using CFD Analysis)

  • 이민구;정경권
    • 한국정보통신학회논문지
    • /
    • 제16권7호
    • /
    • pp.1559-1566
    • /
    • 2012
  • 본 논문에서는 실거주 환경과 같이 구축된 테스트베드에 온도 센서를 설치하여 최적의 온도 측정 위치를 설정하는 방법을 제안한다. 테스트베드를 CFD(Computational Fluid Dynamics) 방법으로 온도 변화를 시뮬레이션하고, 온도 변화와 기류 변화를 확인하여 최적 온도 측정 위치를 선정한다. 디자인빌더 소프트웨어를 이용하여 테스트베드를 3차원 모델링을 하고 CFD를 실행하였다. 최적위치는 바닥에서 높이 1.5m이고, 온도 변화가 적은 곳을 선택하였다. 실제 공간에 30개의 온습도센서를 설치하여 실험을 진행하였고 온도변화 결과를 확인하였다.