• Title/Summary/Keyword: chamber method

Search Result 1,708, Processing Time 0.031 seconds

Development of Unfolding Energy Spectrum with Clinical Linear Accelerator based on Transmission Data (물질투과율 측정정보 기반 의료용 선형가속기의 에너지스펙트럼 유도기술 개발)

  • Choi, Hyun Joon;Park, Hyo Jun;Yoo, Do Hyeon;Kim, Byoung-Chul;Yi, Chul-Young;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Background: For the accurate dose assessment in radiation therapy, energy spectrum of the photon beam generated from the linac head is essential. The aim of this study is to develop the technique to accurately unfolding the energy spectrum with the transmission analysis method. Materials and Methods: Clinical linear accelerator and Monet Carlo method was employed to evaluate the transmission signals according to the thickness of the observer material, and then the response function of the ion chamber response was determined with the mono energy beam. Finally the energy spectrum was unfolded with HEPROW program. Elekta Synergy Flatform and Geant4 tool kits was used in this study. Results and Discussion: In the comparison between calculated and measured transmission signals using aluminum alloy as an attenuator, root mean squared error was 0.43%. In the comparison between unfolded spectrum using HEPROW program and calculated spectrum using Geant4, the difference of peak and mean energy were 0.066 and 0.03 MeV, respectively. However, for the accurate prediction of the energy spectrum, additional experiment with various type of material and improvement of the unfolding program is required. Conclusion: In this research, it is demonstrated that unfolding spectra technique could be used in megavoltage photon beam with aluminum alloy and HEPROW program.

Study of Synthesis and Biological Function on Aminophosphonic Acids (Aminophosphonic Acids 화합물의 생물학적 기능연구)

  • Kim, Sook-He
    • Journal of Nutrition and Health
    • /
    • v.4 no.4
    • /
    • pp.39-46
    • /
    • 1971
  • Since ${\beta}-aminoethylphosphonic$ acid was discovered in the living organism, the biosynthesis and biological function of aminophosphonic acids have been extensively studied. The purpose of this project consists in the two parts: 1)the preparation of DL-1-amino-2-phenylethylphosphonic acid (Phenylalanine aminophosphonic acid) and DL-1-amino-3-methylbutyl-phosphonic acid (Isoleucine aminophosphonic acid) by the method of Chamber and Isbell. 2) the study of metabolism and biological functions of those synthetic materials by the animal experiment (white rats) The importance of this project proved to be the first experience fed by animals for the elucidation of biochemical and metabolic functions in the animal body. The following organic synthesis of DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenylethylphosphonic acid are studied. 1)Synthesis of DL-1-amino-3-methylbutylphosphonic acid a) Synthesis of Iso-butylbromide b) Synthesis of Ethyl iso-butylmalonate c) Synthesis of Iso-caproic acid d) Synthesis of $Ethyl-{\alpha}-bromo$ iso-caproate e) Synthesis of $Triethyl-{\alpha}-phosphono$ iso-caproate f) Synthesis of DL-1-amino-3-methylbutylphosphonic acid 2)Synthesis of DL-1-amino-2-phenylethylphosphonic acid a) Synthesis of Diethyl phosphite b) Synthesis of Ethylchloro acetate c) Synthesis of Triethyl phospho acetate d) Synthesis of Triethyl benzyl phospho acetate e) Synthesis of DL-1-amino-2-phenylethylphosphonic acid The synthetic compounds; DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenyl ethylphosphonic acid which are essential amino acid (isoleucine, phenylalanine)analogue are supplemented to the animal diet at the level of 0.2% and 0.4% for isoleucine analogue and 0.35% and 0.7% for phenylalanine analogue. The plain isoleucine and phenylalanine at the same level in the diet are fercilitated as comparable groups in this study. Two sets of experience including 100 male rats were carried out for seven weeks each total 14 weeks. During this period, urine samples, and each big organs were collected for the analysis of total nitrogen, phosphorus, and glycogen contents in the individual samples by Micro Kjeldahl Fisk & Subbarow and Nelson Somogye, method. 1) The result of the project a) The yield of DL-1-amino-3-methylbutylphosphonic acid and DL-1-amino-2-phenylethylphosphonic acid showed low tendency at the level of 12.5% and 20% Melting point of those two compounds were very high and the ${\alpha}-amino$ group in the synthetic compounds showed positive reaction with ninhydrin in the violet color. b) Ail the experimental groups included in this study revealed statistically no significant difference in the organ weight, total body nitrogen retention and urinary phosphorus excretion This means isoleucine aminophosphonic acid and Phenylalanine aminophosphonic acid were utilized in the body as much as the plain amino acids, isoleucine and phenylalanine did. c) The glycogen contents in the liver of the phenylalaine aminophosphonic acid gruop showed higher statistically significant(p<0.05) in the comparision with the group of the Phenylalanine and the Standard-2. It was noteworthy that the higher glycogen content in the liver might indicate the significance in the incorporation of phenylalanine aminophosphonic acid into the intermediate of tricarboxylic acid cycle as activated state.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Characteristics of Low Density Fiberboards Bonded with Different Adhesives for Thermal Insulation (II) - Formaldehyde·Total Volatile Organic Compounds Emission Properties and Combustion Shapes - (다양한 접착제로 제조한 단열재용 저밀도섬유판의 특성(II) - 폼알데하이드·총휘발성유기화합물 방출 특성 및 연소 형상 -)

  • Jang, Jae-Hyuk;Lee, Min;Kang, Eun-Chang;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.580-587
    • /
    • 2017
  • Woodfiber insulation board can be considered as a one of the key material for low energy consumption, comfortable and safety construction of residential space because of its eco-friendly and high thermal insulation performance. This study was carried out to investigate the formaldehyde (HCHO) total volatile organic compounds (TVOC) emission properties and combustion shapes by flame test of low density fiberboards (LDFs) prepared with different adhesives. HCHO TVOC emission and combustion properties of LDFs prepared by melamine urea formaldehyde (MUF), phenol formaldehyde (PF), emulsified methylene diphenyl diisocyanate (eMDI) and latex resin adhesives were measured by desiccator method, 20 L chamber method, and flame test, respectively. As results, LDFs manufactured by MUF, eMDI and latex resin adhesives satisfied the Super $E_0$ grade of HCHO emission performance except PF resin. Furthermore, TVOC emission of all LDFs were satisfied the Korean indoor air quality standard (below $400{\mu}g/m^2{\cdot}h$). Especially, LDF with eMDI resin adhesive showed the lowest HCHO and TVOC emissivity, that $0.14mg/{\ell}$, $12{\mu}g/m^2{\cdot}h$, respectively. However, eMDI emitted the small amount ($3{\mu}g/m^2{\cdot}h$) of toluene in VOC components. In the flame test, LDF with MUF resin adhesives showed the most favorable shape after flame test compare to LDFs prepared other adhesives. Based on HCHO and TVOC emission, and combustion shapes, MUF resin adhesive may be recommended to prepare LDF for insulation purpose.

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Clinic Analysis of Heart Surgery -110 cases- (심장수술 110례 임상고찰)

  • Chang, Hoon;Shin, Sung-Aia;No, Joong-Kee;Rho, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.597-603
    • /
    • 2001
  • Background: The purpose of writing this article is to get better clinical results and further clinical improvement based on subject to 110 cases of cardiac surgery which were performed and clinically analyzed. Material and Method: Since January 1995, the patent ductus arteriosus surgery had started in our hospital. In February 1999, an open heart surgery had started and up to September 2000, total of 110 cases were performed as of double ligation of patent ductus arteriosus(10 cases) and open heart surgery(100 cases). Result: Among the patients, Korean-Chines was 74(67.3%) and Han-Chinese was 35(31.8%). Congenital heart disease was 95 cases and acquired valvular heart disease was 15 cases. 83 cases of acyanotic congenital heart disease consisted of ventricular septal defect(VSD) with associated anomaly(45 cases), atrial septal defect(ASD) with associated anomaly(20 cases), patent ductus arteriosus(PDA) with associated anomaly(11 cases), cogenital aortic stenosis(5 cases), double chamber right ventrical(1 case) and Ebstein's anomaly(1 case). Among the 12 cases of cyanotic congenital heart disease, 11 cases of tetralogy of Fallot underwent total correction. Among the 15 cases of acquired valvular heart disease, valvular replacement(7 cases), double valve replacement (3 cases), mitral valve replacement(3 cases) and aortic valve replacement(1 case) were performed. And 8 cases of valvuloplasty were performed by using of commissurotomy, chordal plasty, plasty of papillary muscle, ring type annuloplasty, repair of leaflet. Conclusion: on cogenital heart disease, short term results of surgery for acyanotic cogenital heart disease was good. Among the cyanotic congenital heart disease, tetralogy of Fallot showed a little difference of recovery according to the surgery method so that further follow up observation was needed for long term result. On acquired valvular heart disease, especially, in terms of short term result of valvuloplasty, was relatively good, but further follow up observation was also needed for long term result. There wasn's any operative mortality.

  • PDF

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.

Effect of micro-environment in ridge and southern slope on soil respiration in Quercus mongolica forest

  • Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Background: Soil respiration (Rs) is a major factor of the absorption and accumulation of carbon through photosynthesis in the ecosystem carbon cycle. This directly affects the amount of net ecosystem productivity, which affects the stability and sustainability of the ecosystem. Understanding the characteristics of Rs is indispensable to scientifically understand the carbon cycle of ecosystems. It is very important to study Rs characteristics through analysis of environmental factors closely related to Rs. Rs is affected by various environmental factors, such as temperature, precipitation, soil moisture, litter supply, organic matter content, dominant plant species, and soil disturbance. This study was conducted to analyze the effects of micro-topographical differences on Rs in forest vegetation by measuring the Rs on the ridge and southern slope sites of the broadly established Quercus mongolica forest in the central Korean area. Method: Rs, Ts, and soil moisture data were collected at the southern slope and ridge of the Q. mongolica forest in the Mt. Jeombong area in order to investigate the effects of topographical differences on Rs. Rs was collected by the closed chamber method, and data collection was performed from May 2011 to October 2013, except Winter seasons from November to April or May. For collecting the raw data of Rs in the field, acrylic collars were placed at the ridge and southern slope of the forest. The accumulated surface litter and the soil organic matter content (SOMC) were measured to a 5 cm depth. Based on these data, the Rs characteristics of the slope and ridge were analyzed. Results: Rs showed a distinct seasonal variation pattern in both the ridge and southern slope sites. In addition, Rs showed a distinct seasonal variation with high and low Ts changes. The average Rs measurements for the two sites, except for the Winter periods that were not measured, were $550.1\;mg\;CO_2m^{-2}h^{-1}$ at the ridge site and $289.4\;mg\;CO_2m^{-2}h^{-1}$ at the southern slope, a difference of 52.6%. There was no significant difference in the Rs difference between slopes except for the first half of 2013, and both sites showed a tendency to increase exponentially as Ts increased. In addition, although the correlation is low, the difference in Rs between sites tended to increase as Ts increased. SMC showed a large fluctuation at the southern slope site relative to the ridge site, as while it was very low in 2013, it was high in 2011 and 2012. The accumulated litter of the soil surface and the SOMC at the depth range of 0~5 cm were $874g\;m^{-2}$ and 23.3% at the ridge site, and $396g\;m^{-2}$ and 19.9% at the southern slope site. Conclusions: In this study, Rs was measured for the ridge and southern slope sites, which have two different results where the surface litter layer is disturbed by strong winds. The southern slope site shows that the litter layer formed in autumn due to strong winds almost disappeared, and while in the ridge site, it became thick due to the transfer of litter from the southern slope site. The mean Rs was about two times higher in the ridge site compared to that in the southern slope site. The Rs difference seems to be due to the difference in the amount of litter accumulated on the soil surface. As a result, the litter layer supplied to the soil surface is disturbed due to the micro-topographical difference, as the slope and the change of the community structure due to the plant season cause heterogeneity of the litter layer development, which in turn affects SMC and Rs. Therefore, it is necessary to introduce and understand these micro-topographical features and mechanisms when quantifying and analyzing the Rs of an ecosystem.

The Study on the Effect of Target Volume in DQA based on MLC log file (MLC 로그 파일 기반 DQA에서 타깃 용적에 따른 영향 연구)

  • Shin, Dong Jin;Jung, Dong Min;Cho, Kang Chul;Kim, Ji Hoon;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.53-59
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the difference between the MLC log file-based software (Mobius) and the conventional phantom-ionization chamber (ArcCheck) dose verification method according to the change of target volume. Material and method: Radius 0.25cm, 0.5cm, 1cm, 2cm, 3cm, 4cm, 5cm, 6cm, 7cm, 8cm, 9cm, 10cm with a Sphere-shaped target Twelve plans were created and dose verification using Mobius and ArcCheck was conducted three times each. The irradiated data were compared and analyzed using the point dose error value and the gamma passing rate (3%/3mm) as evaluation indicators. Result: Mobius point dose error values were -9.87% at a radius of 0.25cm and -4.39% at 0.5cm, and the error value was within 3% at the remaining target volume. The gamma passing rate was 95% at a radius of 9cm and 93.9% at 10cm, and a passing rate of more than 95% was shown in the remaining target volume. In ArcCheck, the average error value of the point dose was about 2% in all target volumes. The gamma passing rate also showed a pass rate of 98% or more in all target volumes. Conclusion: For small targets with a radius of 0.5cm or less or a large target with a radius of 9cm or more, considering the uncertainty of DQA based on MLC log files, phantom-ionized DQA is used in complementary ways to include point dose, gamma index, DVH, and target coverage. It is believed that it is desirable to verify the dose delivery through a comprehensive analysis.