• Title/Summary/Keyword: chamber method

Search Result 1,708, Processing Time 0.025 seconds

Characteristics of Fuel Mixing and Evaporation Based on Impingement Plate Shape in a Denitrification NOx System with a Secondary Injection Unit (2차 분사시스템을 갖는 De-NOx 시스템의 충돌판 형상에 따른 연료의 혼합 및 증발 특성 향상을 위한 연구)

  • Park, Sangki;Oh, Jungmo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.884-891
    • /
    • 2016
  • A secondary injection system in a diesel engine has benefits: it can be controlled independently without interrupting engine control, it can be adapted to various layouts for exhaust systems, and it pose no reductant dilution problems compared to post injection systems in the combustion chamber or other supplemental reductant injections. In a secondary injection system, the efficiency of the catalyst depends on the method of reducing the supply. The reductant needs to be maintained and optimized with constant pressure, the positions and angles of injector is a very important factor. The concentration and amount of reductant can be changed by adjusting secondary injection conditions. However, secondary injection is highly dependent upon the type of injector, injection pressure, atomization, spray technology, etc. Therefore, it is necessary to establish injection conditions the spray characteristics must be well-understood, such as spray penetration, sauter mean diameter, spray angle, injection quantity, etc. Uniform distribution of the reductant corresponding to the maximum NOx reduction in the DeNOx catalyst system must also assured. With this goal in mind, the spray characteristics and impingement plate types of a secondary injector were analyzed using visualization and digital image processing techniques.

THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS (무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향)

  • Choi, Seung-Ho;Ro, Byeng-Duck;Park, Sung-Ho;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

Formation of Magnesium Films on Galvanized Steel Substrates by PVD Method at Nitrogen Gas Pressures and Their Corrosion Resistances (질소가스 중 PVD법에 의해 용융아연도금 강판 상에 형성한 마그네슘 막의 내식특성)

  • Eom, Jin-Hwan;Park, Jae-Hyeok;Hwang, Seong-Hwa;Park, Jun-Mu;Yun, Yong-Seop;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.182-182
    • /
    • 2016
  • 철강은 기본적으로 강도가 우수하고 그 매장량이 풍부할 뿐만 아니라 대량생산이 가능하다 또한 다른 금속과 합금을 구성하여 또 다른 특성을 부여할 수 있기 때문에 현재 전 세계 금속 생산량의 95%를 차지할 정도로 많이 사용되며, 각종 산업과 기술이 발달함에 따라 그 중요도는 점점 더 커져가고 있다. 하지만 철강은 사용 환경 중 부식에 의해 그 수명과 성능이 급격히 저하되기 때문에 내식성을 향상시키기 위하여 도장이나 도금 등의 표면처리를 포함한 다양한 방법이 적용되고 있다. 그 중 철강재의 도금 표면처리방법은 주로 아연을 이용한 용융도금이나 전기도금 등과 같은 습식 프로세스가 널리 사용되고 있다. 여기서 아연은 철보다 이온화 경향은 크나 대기 환경 중 산소와 물과 반응하여 Zn(OH)2와 같은 화합물을 형성함으로써 철강재 표면상 부식인자를 차단(Barrier)함은 물론 사용 중 철 모재가 노출되는 결함이 발생하는 경우에는 철을 대신하여 희생양극(Sacrificial Anode) 역할을 하기 때문에 철의 부식방식용 금속으로 가장 많이 사용되고 있다. 한편 최근에는 철강의 사용 환경이 다양해짐은 물론 가혹해지고 있어서 이에 따른 내식성 향상이 계속해서 요구되고 있는 추세이다. 따라서 본 연구에서는 철강재의 내식성을 향상시키기 위한 일환으로 현재 많이 사용되고 있는 용융아연도금 강판 상에 아연보다 활성이 높은 마그네슘(Mg)을 건식 프로세스 방법 중에 하나인 PVD(Physical Vapour Deposition)법에 의해 코팅하는 것을 시도하였다. 일반적으로 PVD법에 의해 진공증착하는 경우에는 그 도입가스로써 불활성가스인 아르곤(Ar)을 사용하는 경우가 대부분이나 여기서는 상대적으로 비활성이면서 그 크기가 작은 질소(N2)가스를 도입하여 그 증착 막의 몰포로지는 물론 결정구조도 제어하여 그 내식특성을 향상시키고자 하였다. 본 연구에서는 철강재의 내식성을 향상시키기 위한 방법으로 마그네슘(Mg)를 PVD(Physical Vapor Deposition)법 중 진공증착법(Vacuum Deposition)을 사용하여 용융아연도금 강판 상에 마그네슘 증착 막을 형성하였다. 즉, 여기서는 진공증착 중 질소(Nitrogen, N2)가스를 도입하여 진공챔버(Vacuum Chamber)내의 진공도를 $1{\times}10^{-1}$, $1{\times}10^{-2}$, $1{\times}10^{-3}$, $1{\times}10^{-4}$로 조절하며 제작하였다. 또한 제작된 시편에 대해서는 SEM(Scanning Electron Microscope) 및 XRD(X-Ray Diffraction)을 사용하여 형성된 아연도금상 마그네슘 막의 표면 몰포로지 및 결정구조의 변화를 분석함은 물론 침지시험, 염수분무시험, 분극시험을 통해 이 막들에 대한 내식특성을 분석 평가하였다. 상기 실험결과에 의하면, 진공 가스압이 증가됨에 따라 마그네슘 막의 두께는 감소하였으며, 그 몰포로지의 단면은 주상정(Columnar)에서 입상정(Granular) 구조로 변화하며 표면의 결정립은 점점 미세화 되는 경향을 나타냈다. 이때의 표면의 결정배향성(Crystal orientation)은 표면에너지가 상대적으로 큰 면이 우세하게 나타나는 경향이 있었다. 또한 본 실험에서 형성한 진공증착 막은 비교재인 용융아연도금강판보다 우수한 내식성을 나타냈고, 본 형성 막 중에는 마그네슘 막 두께가 작음에도 불구하고 질소 가스압이 가장 큰 조건일수록 내식성이 우수한 경향을 나타냈다. 이상의 결과는 철강재의 내식성 향상을 위한 응용표면처리설계에 기초적인 지침을 제공할 수 있을 것으로 기대된다.

  • PDF

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Pressurization Characteristics of Piezoelectric-Hydraulic Pump Adopting a Ball-Thin Plate Spring Type Check Valve (볼-박판 스프링 형 체크밸브가 적용된 압전유압펌프의 가압 특성)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 2018
  • In this study, a new check valve was studied to improve the load pressure of a brake system with a small piezoelectric-hydraulic pump. During the pressurization process, the steady-state pressure at the load is affected by the ratio of the cross-sectional area of the check valve the chamber pressure and load pressure. Since the flow path cover of the check valve is made wider than the cross-sectional area of the output flow to prevent backflow, a method of reducing the area ratio is proposed for a higher load pressure by mounting an additional mass to a thin plate spring type check valve. To identify the effect of mounting an additional mass to the existing check valve on the load pressure, a simple brake system with a small piezoelectric-hydraulic pump was modeled using a commercial code AMESim. The AMESim modeling was verified by comparing the simulation results with the experimental results of the pump the existing check valve. The additional mass was added to the verified AMESim modeling and higher load pressure was able to be obtained through simulation. The 35% performance improvement in load pressure identified by carrying out pressurization test of the brake system after adopting the new check valve the small piezoelectric-hydraulic pump.

Standard Measurement Procedure for Soil Radon Exhalation Rate and Its Uncertainty

  • Seo, Jihye;Nirwono, Muttaqin Margo;Park, Seong Jin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2018
  • Background: Radon contributing about 42% of annual average dose, mainly comes from soil. In this paper, standard measurement procedures for soil radon exhalation rate are suggested and their measurement uncertainties are analyzed. Materials and Methods: We used accumulation method for estimating surface exhalation rate. The closed-loop measurement system was made up with a RAD7 detector and a surface chamber. Radon activity concentrations in the system were observed as a function of time, with data collection of 5 and 15-minute and the measurement time of 4 hours. Linear and exponential fittings were used to obtain radon exhalation rates from observed data. Standard deviations of measurement uncertainties for two approaches were estimated using usual propagation rules. Results and Discussion: The exhalation rates (E) from linear approach, with 30 minutes measurement time were $44.8-48.6mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.14-2.32atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with relative measurement uncertainty of about 10%. The contributions of fitting parameter A, volume (V) and surface (S) to the estimated measurement uncertainty of E were 59.8%, 30.1% and 10.1%, in average respectively. In exponential fitting, at 3-hour measurement we had E ranged of $51.6-69.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.46-3.30atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with about 15% relative uncertainty. Fitting with 4-hour measurement resulted E about $51.3-68.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.45-3.25atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with 10% relative uncertainty. The uncertainty contributions in exponential approach were 75.1%, 13.4%, 8.7%, and 2.9% for total decay constant k, fitting parameter B, V, and S, respectively. Conclusion: In obtaining exhalation rates, the linear approach is easy to apply, but by saturation feature of radon concentrations, the slope tends to decrease away from the expected slope for extended measurement time. For linear approach, measurement time of 1-hour or less was suggested. For exponential approach, the obtained exhalation rates showed similar values for any measurement time, but measurement time of 3-hour or more was suggested for about 10% relative uncertainty.

Effect of Liposome Encapsulation on Intestinal Absorption of Rhodamine 123 (리포솜 봉입이 로다민 123의 소장 흡수에 미치는 영향)

  • Hong, Soon-Sun;Lee, Hae-Ree;Li, Hong;Chung, Suk-Jae;Kim, Dae-Duk;Shim, Chang-Koo
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.185-191
    • /
    • 2005
  • The absorption of a P-gp substrate, rhodamine 123, from a liposomal dosage form was investigated across Caco-2 cell monolayers, rat intestines and rat intestinal Peyer's patches in Ussing chamber, Rhodamine 123 was incorporated into liposomes according to the standard evaporation method, which led to a production of liposomes with a mean diameter of 71.3 nm. The permeability (Papp of rhodamine 123 from a water solution across the monolayer was $2.45{\times}10^{-6}$ cm/s for $A{\leftrightarrow}B$ (apical to basal) and $14.0{\times}10^{-6}$ cm/s for $B{\leftrightarrow}A$ (basal to apical) directions, consistent with the fact that rhodamine 123 is one of the P-gp substrates. The transport of rhodamine 123 from the liposomal dosage form was much lower for both directions compared to the solution of rhodamine 123. The transport of rhodamine 123 across the rat intestine was also significantly decreased for both directions, I.e., influx and efflux, by the liposomal incorporation of the compound. The transport of rhodamine 123 across the Peyer's patch was substantially reduced by liposomal incorporation. No difference was found in the transport between the Peyer's patch and non-Peyer's patch. These observations suggest that the contribution of transport via Peyer's patches in the uptake of liposomes may be minimal, especially for rapidly absorbed compounds like rhodamine 123. Therefore, the increased absorption of P-gp substrates does not appear to be feasible by incorporating the compounds in liposomes, due to negligible involvement of Peyer's patches in the uptake of particulate dosage forms like liposomes. Liposomes may rather represent a sustained release dosage form of incorporated compounds.

Effect of Gypsum Application on Reducing Methane (CH4) Emission in a Reclaimed Coastal Paddy Soil (간척지 논 토양 개량제로서 석고처리가 메탄 배출량 저감에 미치는 영향)

  • Lim, Chang-Hyun;Kim, Sang-Yoon;Kim, Pil-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.243-251
    • /
    • 2011
  • BACKGROUND: Gypsum($CaSO_4{\cdot}2H_2O$) is known as an ideal amendment to improve soil quality of the reclaimed coastal land. Since gypsum has very high concentration of electron acceptor like ${SO_4}^{2-}$, its application might be effective on reducing $CH_4$ emission during rice cultivation, but its effect has not been studied well. METHODS AND RESULTS: The effect of gypsum on $CH_4$ emission and rice growth characteristics was studied by pot test, which was packed by reclaimed paddy soils collected from Galsa, Hadong, Gyeongnam province. Chemical-grade gypsum was applied in two soils having EC 2.25 and 9.48 dS/m at rates of 0, 0.5, 1.0 and 2.0%(wt/wt). $CH_4$ emission was characterized a week interval by closed chamber method during rice cultivation. $CH_4$ emission rate was significantly decreased with increasing salt accumulation and gypsum application levels. With increasing gypsum application, dissolved ${SO_4}^{2-}$ concentration in the leachate water was significantly increased, which might have suppressed $CH_4$ production in soil. Total $CH_4$ flux was dramatically decreased with increasing gypsum application. In contrast, rice yield was increased with increasing gypsum application and then achieved maximum productivity at 1.0% gypsum application in two soils. CONCLUSION(s): Gypsum is a very good soil amendment to suppress $CH_4$ emission in reclaimed coastal paddy soils, and improve rice productivity and soil properties. The optimum application level of gypsum is assumed at ca. 1% to improve soil productivity with reducing effectively $CH_4$ emission during rice cultivation.

The Effect of Flooding Time on Ammonia Emission after Application of Liquid Pig Manure in Paddy Soil (돈분뇨 시용 후 담수시기가 암모니아 휘산에 미치는 영향)

  • Lee, Yong-Bok;Lee, Youn;Shin, Pyung-Gyun;Yun, Hong-Bae
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.4
    • /
    • pp.377-381
    • /
    • 2011
  • BACKGROUND: Ammonia emissions from field-applied livestock manure are considered a threat to the environment worldwide. In Korea, a large amount of liquid manure was applied in the rice field before rice transplanting in order to reduce chemical fertilizer use. This study was conducted to provide the optimal flooding time after liquid manure application in an attempt to minimize ammonia emission. METHODS AND RESULTS: Ammonia emission from paddy field applied with liquid pig manure following different flooding time was measured using the dynamic chamber method. The five treatments used were : application of liquid pig manure to paddy field in flooding condition (F0T); one day (F1T) and three days (F3T) after flooding; without flooding (NF), and flooding without the application of liquid pig manure (control). Among the treatment, the highest ammonia emission was observed in F0T. The cumulative ammonia emission of F1T and F3T for 12 days were very similar and were about 4.7 times less than that of the F0T treatment. CONCLUSIONS: Ammonia emission in paddy field could be significantly reduced by liquid pig manure application after flooding rather than application of liquid pig manure in flooding condition. Therefore, flooding after liquid pig manure application would provide much more nitrogen for rice growth due to the reduction of ammonia emission.