• Title/Summary/Keyword: centrifuge study

Search Result 258, Processing Time 0.025 seconds

Two-dimensional deformation measurement in the centrifuge model test using particle image velocimetry

  • Li, J.C.;Zhu, B.;Ye, X.W.;Liu, T.W.;Chen, Y.M.
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.793-802
    • /
    • 2019
  • The centrifuge model test is usually used for two-dimensional deformation and instability study of the soil slopes. As a typical loose slope, the municipal solid waste (MSW) landfill is easy to slide with large deformation, under high water levels or large earthquakes. A series of centrifuge model tests of landfill slide induced by rising water level and earthquake were carried out. The particle image velocimetry (PIV), laser displacement transducer (LDT) and marker tracer (MT) methods were used to measure the deformation of the landfill under different centrifugal accelerations, water levels and earthquake magnitudes. The PIV method realized the observation of continuous deformation of the landfill model, and its results were consistent with those by LDT, which had higher precision than the MT method. The deformation of the landfill was mainly vertically downward and increased linearly with the rising centrifugal acceleration. When the water level rose, the horizontal deformation of the landfill developed gradually due to the seepage, and a global slide surface formed when the critical water level was reached. The seismic deformation of the landfill was mainly vertical at a low water level, but significant horizontal deformation occurred under a high water level. The results of the tests and analyses verified the applicability of PIV in the two-dimensional deformation measurement in the centrifuge model tests of the MSW landfill, and provide an important basis for revealing the instability mechanism of landfills under extreme hydraulic and seismic conditions.

Centrifuge Test for Simulating Behavior of CFRD During Initial Impoundment (초기 담수시 CFRD 거동 모사를 위한 원심모형실험)

  • Seo, Min-Woo;Kim, Yong-Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.109-119
    • /
    • 2007
  • As the number of CFRD constructions increases, the necessity of an accurate assessment on its behavior also has been increasing. The performance of concrete faced rockfill dam (CFRD) under different water levels is a great concern of dam engineers and designers in the world. However, domestic research on CFRD design and construction has not been performed sufficiently. This study deals with three centrifuge model tests, mainly investigates quantitatively the deformation of the concrete faced slabs and settlements on the crest with different face slab stiffness. The prototype of a centrifugal model dam is half size of domestic CFRD dam. Detailed material preparation, model design, model set-up, model instrumentation and testing procedures are presented. In order to simulate the prototype concrete faced slab, three kinds of thin fiberglass plates with different thickness were adopted in three model tests. Finally, the centrifuge test results were compared with field measurements of domestic dams, which showed that the centrifuge tests were performed successfully.

A Numerical Study on the NATM Tunnel Reinforcement using Centrifuge Model Experimental value (실험값을 이용한 NATM 터널의 보강효과에 관한 수치 해석적 연구)

  • Huh, Kyung-Han;Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.13-18
    • /
    • 2004
  • In this study, in the first place, parameters primarily influencing displacement and stress were constructed by using the Finite Difference Method; then using those parameters, the result of crown displacement and convergence among the existing, experimental values of a centrifuge model were compared with the result of numerical analysis; and then considering the stress and time effect of lining installation, parameters according to the difference of stiffness were studied. In the result of this study, it found out that rough, ground reinforcement effect manifests itself when reinforcement propert of the grouting of the big scale steel pipe through 3-D analysis is E= 4,000tf/m2 which of the stiffness of the original ground.

A Study on Centrifuge Model Experiments of Soft Soil Ground Installed with PBD (PBD가 설치된 연약지반의 원심모형실험에 관한 연구)

  • Jeong, Gil-Soo;Park, Byung-Soo;Jeon, Sang-Hyun;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.101-108
    • /
    • 2006
  • This study is the results of experimental and numerical study on the consolidational behavior of multi-layered soft soil ground installed with plastic board drains (PBD). Centrifuge model tests with a marine clay sampled from field were performed to investigate the consolidational behavior of multi-layered ground where a dredged soil was placed on the soft clay ground and PBDs were installed. Test results were compared with those of numerical analyses, using the 2-D equivalent model previously proposed. From test results, it was found that the amount of consolidation settlement occurred in the original ground due to embankment surcharge loads was in the range of 38% of total settlement in the whole ground. From the results of cone penetration tests executed after finishing the centrifuge model tests, the cone resistance was found to increase with depth. The measured water contents inbetween PBDs were in the ranges of 38~50% and their values tended to increase with increasing the distance between PBDs.

  • PDF

A Study on Geotechnical Centrifuge Testing Method for Seismic Performance Evaluation of Large Embankment Dams (대형 댐의 지진응답특성평가를 위한 원심모형시험 기법 연구)

  • Kim, Nam-Ryong;Lim, Jeong-Yeul;Im, Eun-Sang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.201-209
    • /
    • 2016
  • Damages of large embankment dams by recent strong earthquakes in the world highlight the importance of seismic security of dams. Some of recent dam construction projects for water storage and hydropower are located in highly seismic zone, hence the seismic performance evaluation is an important issue. While state-of-the-art numerical analysis technology is generally utilized in practice for seismic performance evaluation of large dams, physical modeling is also carried out where new construction technology is involved or numerical analysis technology cannot simulate the behavior appropriately. Geotechnical centrifuge modeling is widely adopted in earthquake engineering to simulate the seismic behavior of large earth structures, but sometimes it can't be applied for large embankment dams due to various limitations. This study proposes a dynamic centrifuge testing method for large embankment dams and evaluated its applicability. Scaling relations for a case which model scale and g-level are different could be derived considering the stress conditions and predominant period of the structure, which is equivalent to previously suggested scaling relations. The scaling principles and testing method could be verified by modified modeling of models using a model at different acceleration levels. Finally, its applicability was examined by centrifuge tests for an embankment dam in Korea.

A Study on Characteristic of Sedimentation-Consolidation Conduct for Dredged Soil through Geo-Centrifuge Test (원심모형실험을 이용한 준설토의 침강압밀 거동 특성)

  • Park, Hyunchul;Kang, Hongsig;Sun, Seokyoun;Park, Jongseo;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • The costal reclamation construction is for making reclaimed land by dredging marine clay with seawater, and then bringing the dredged soil into the reclaimed land. During the process, the dredged soil in the reclaimed land undergoes the sedimentation-consolidation process. Among the processes, the consolidation is a very critical factor when planning reclaimed land because of its requiring time and settlement. In order to predict the requiring time and settlement, the Column test, which was suggested by Yano, has been usually used in the nation. However, the test method needs a very long time to identify the characteristic of sedimentation-consolidation of dredged soil. Therefore, in this study, in order to supplement the weakness of the Column test which needs such a long time, and in order to identify the characteristic of the sedimentation-consolidation for dredged soil in a short time, the Geo-centrifuge test was examined as an alternative method. The result considered that Geo-centrifuge test would be useful to identify the characteristic of sedimentation-consolidation for dredged soil efficiently.

Study on the Improvement of Response Spectrum Analysis of Pile-supported Wharf with Virtual Fixed Point (가상고정점기법이 적용된 잔교식 구조물의 응답스펙트 럼해석법 개선사항 도출 연구)

  • Yun, Jung Won;Han, Jin Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.311-322
    • /
    • 2018
  • As a method of seismic-design for pile-supported wharves, equivalent static analysis, response spectrum analysis, and time history analysis method are applied. Among them, the response spectrum analysis is widely used to obtain the maximum response of a structure. Because the ground is not modeled in the response spectrum analysis of pile-supported wharves, the amplified input ground acceleration should be calculated by ground classification or seismic response analysis. However, it is difficult to calculate the input ground acceleration through ground classification because the pile-supported wharf is build on inclined ground, the methods to calculate the input ground acceleration proposed in the standards are different. Therefore, in this study, the dynamic centrifuge model tests and the response spectrum analysis were carried out to calculate the appropriate input ground acceleration. The pile moment in response spectrum analysis and the dynamic centrifuge model tests were compared. As a result of comparison, it was shown that the response spectrum analysis results using the amplified acceleration in the ground surface were appropriate.

Centrifuge modelling of pile-soil interaction in liquefiable slopes

  • Haigh, Stuart K.;Gopal Madabhushi, S.P.
    • Geomechanics and Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-16
    • /
    • 2011
  • Piles passing through sloping liquefiable deposits are prone to lateral loading if these deposits liquefy and flow during earthquakes. These lateral loads caused by the relative soil-pile movement will induce bending in the piles and may result in failure of the piles or excessive pile-head displacement. Whilst the weak nature of the flowing liquefied soil would suggest that only small loads would be exerted on the piles, it is known from case histories that piles do fail owing to the influence of laterally spreading soils. It will be shown, based on dynamic centrifuge test data, that dilatant behaviour of soil close to the pile is the major cause of these considerable transient lateral loads which are transferred to the pile. This paper reports the results of geotechnical centrifuge tests in which models of gently sloping liquefiable sand with pile foundations passing through them were subjected to earthquake excitation. The soil close to the pile was instrumented with pore-pressure transducers and contact stress cells in order to monitor the interaction between soil and pile and to track the soil stress state both upslope and downslope of the pile. The presence of instrumentation measuring pore-pressure and lateral stress close to the pile in the research described in this paper gives the opportunity to better study the soil stress state close to the pile and to compare the loads measured as being applied to the piles by the laterally spreading soils with those suggested by the JRA design code. This test data shows that lateral stresses much greater than one might expect from calculations based on the residual strength of liquefied soil may be applied to piles in flowing liquefied slopes owing to the dilative behaviour of the liquefied soil. It is shown at least for the particular geometry studied that the current JRA design code can be un-conservative by a factor of three for these dilation-affected transient lateral loads.

Seismic behaviors of twin tunnel with flexible segment (Flexible Segment가 설치된 병렬터널의 지진시 동적거동)

  • Kwak, Chang-Won;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.695-702
    • /
    • 2015
  • Recently, the improvement of mechanical and theoretical issues in geo-centrifuge test enhances the applicability and accuracy of the test. Geo-centrifuge test is appropriate to simulate the behaviors of underground structures like tunnel, since tunnel interacts with the soil and/or rock around it and the test can embody the in-situ stress conditions effectively. In this study, the seismic behaviors of twin tunnel were analyzed based on geo-centrifuge test. Flexible segment to mitigate seismic acceleration were implemented in the model with thin and thick thickness. Based on the test results, it was found that flexible segment can decrease the peak acceleration generally, however, thin flexible segment was not able to reduce peak acceleration in short-period seismic wave. Thick flexible segment was more effective in case of high bedrock acceleration condition. Additionally, 3-dimensional numerical analysis was performed to verify the characteristics of seismic behavior and the effect of flexible segment. Consequently, the numerical analysis result showed good agreement with the test result.

Modelling of Soil Extraction Technique for Restoration of Building Tilt from Geotechnical Centrifuge Tests (원심모형실험을 통한 기울어진 건물의 기울기 교정에 이용되는 Soil Extraction 공법의 모델링)

  • Lee Cheol Ju;Ng C.W.W.
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.121-126
    • /
    • 2005
  • It is not uncommon to observe tilt of buildings and towers as a result of unexpected differential foundation settlements. Over the years, a number of engineering methods including the soil extraction technique have been attempted to reduce inclination of buildings and towers. In this research, a series of novel geotechnical centrifuge model tests by using a state-of-the-art in-flit robotic manipulator have been conducted to study key factors which govern the restoration of building tilts. In the centrifuge model tests, the robotic manipulator was used to drill and extract soil in-flight near an initially tilted model building. The soil extraction was to induce stress release, thereby mitigating the inclination of the model building. Insights into the effects of different configurations, soil density and sequences of drilling observed during the centrifuge model tests on the restoration of the model building are to be investigated.