• Title/Summary/Keyword: central control

Search Result 2,501, Processing Time 0.03 seconds

A High-Efficiency Bidirectional AC/DC Topology for V2G Applications

  • Su, Mei;Li, Hua;Sun, Yao;Xiong, Wenjing
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.899-907
    • /
    • 2014
  • This paper proposes a single-phase bidirectional AC/DC converter topology applied in V2G systems, which consists of an inverter and a bidirectional non-inverting buck-boost converter. This topology can operate in four modes: buck charging, boost charging, buck discharging and boost discharging with high input current quality and unity input power factor. The inverter switches at line frequency, which is different from conventional voltage source inverters. A bidirectional buck-boost converter is utilized to adapt to a wider charging voltage range. The modulation and control strategy is introduced in detail, and the switching patterns are optimized to reduce the current ripple. In addition, the semiconductor losses are analyzed. Simulation and experimental results demonstrate the validity and effectiveness of the proposed topology.

Androgenesis in Mulberry Silkworm Bombyx mori L. : A Review

  • Singh, Ravindra;Rao, D.Raghavendra;Kariappa, B.K.;Jayaswal, K.P.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.3 no.2
    • /
    • pp.109-112
    • /
    • 2001
  • Androgenesis in silkworm acquires a special significance as along with combined applications of other breeding strategies like parthenogenesis and cloning, it may serve as n valuable tool for sex control in sericulture as well as selection and production of bisexual homozygous androgenetic lines. Production of hybrid silkworm yielding high proportion of male larvae is of immense use to silk industry (Strunnikov, 1975, 1983). In this review, an attempt has been made to assimilate the works carried out on androgenesis, different techniques of induction towards androgenetic development and its role in silkworm breeding.

  • PDF

Improved Reactive Power Sharing for Parallel-operated Inverters in Islanded Microgrids

  • Issa, Walid;Sharkh, Suleiman;Mallick, Tapas;Abusara, Mohammad
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1152-1162
    • /
    • 2016
  • The unequal impedances of the interconnecting cables between paralleled inverters in the island mode of microgrids cause inaccurate reactive power sharing when the traditional droop control is used. Many studies in the literature adopt low speed communications between the inverters and the central control unit to overcome this problem. However, the losses of this communication link can be very detrimental to the performance of the controller. This paper proposes an improved reactive power-sharing control method. It employs infrequent measurements of the voltage at the point of common coupling (PCC) to estimate the output impedance between the inverters and the PCC and then readjust the voltage droop controller gains accordingly. The controller then reverts to being a traditional droop controller using the newly calculated gains. This increases the immunity of the controller against any losses in the communication links between the central control unit and the inverters. The capability of the proposed control method has been demonstrated by simulation and experimental results using a laboratory scale microgrid.

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

An RFID Multi-Reader System Development for TCP/IP Based Security Control (TCP/IP 기반 보안통제 RFID 멀티리더 시스템 개발)

  • Cho, Sung-Mok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1587-1592
    • /
    • 2009
  • RFID is Playing a central role in ubiquitous technology according with the advent of the ubiquitous era, and the development of an RFID reader is also emerging as an important technical development field. In this paper, we developed a hardware system which is able to make use of the 13.56MHz RFID infrastructure being used as a transportation card, a credit card, and so on as well as the 125KHz RFID infrastructure being used in security company, and which is applicable to a location identification, an entrance and exit control, and security control over the TCP/IP communication. The existing local RFID methods have some problems which bottlenecks such as administrative problems, technical problems, and so force frequently occur because a casual server is placed and operated in a company. Hence, in this paper we developed an RFID multi reader which is connected to a central administrable server over the TCP/IP in order to solve these problems, and we make it be possible to keep an security control and be easy to install, transfer and administrate RFID infrastructures.

Cable Functional Failure Time Evaluation for a Main Control Room Fire using Fire Dynamic Simulator (FDS 이용한 주제어실 화재시 케이블 기능상실시간 평가)

  • Lim, Heok-Soon;Kim, In-Hwan;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • Serious electrical problems, such as shorts, ground faults, or circuits, often cause fire events in the fire proof zone of nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety-related systems and equipment. The fire event can be treated with the basic design principle that safety systems should maintain their functions with redundancy and independency. In the case of a cable fire in the main control room, operators cannot perform their mission properly and can misjudge the situation because of spurious operation, incorrect indication or instrument. These would deteriorate the plant capabilities of safety shutdown and result in disastrous conditions. Therefore, during a main control room fire, 5 minutes of operator action time is very important to operate the safety shutdown components. This paper describes the cable functional failure temperature criteria and conducted a cable functional failure time evaluation using Fire Dynamic Simulator to obtain the operator action time for a main control room fire.

Development of the remote management and control system for wireless CATV network (무선 CATV망의 원격 관리 및 제어 시스템의 개발)

  • 송문규;이상설
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.1134-1147
    • /
    • 1998
  • Remote management and control system for LMDS wireless CATV network which is being developed at SK Telecom is developed. This system is composed of central control division located at head center and remote units for remote transceivers equipped in base stations and repeaters. It monitors the state of the remote transceivers and controls the operations using PSTN for iterface. Remote transceivers whould be equipped in pairs, and the operations are exchanged automatically in case of emergency situations. the remote units are designed not only to perform commands form central control division, bet to inform emergency situations such as disorder and power failure. This system works well, which is established at Central research center in SK Telecom with remote units such as BTX, PPTX, and PPRX. This system could be utilized in other applications requiring remote control through sligh modifications.

  • PDF

Effect of graded levels of soapnut (Sapindus mukorossi) shell powder on reproductive performance in broiler breeders

  • Chaudhary, S.K.;Mandal, A.B.;Bhar, R.;Gopi, M.;Kannan, A.;Jadhav, S.E.;Rokade, J.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.1
    • /
    • pp.118-125
    • /
    • 2019
  • Objective: This study investigated the effects of soapnut (Sapindus mukorossi) shell powder (SSP) on serum hormone level, egg quality, semen characteristics and reproductive performance of broiler breeders fed with a maize-soybean meal based diet. Methods: Ninety six female and twenty four male CARIBRO-VISHAL broiler breeders, 38-week old, were individually caged and randomly allocated to four treatment groups (24 female breeders/treatment and 6 male breeders/treatment): an un-supplemented control (T1) and three groups with 0.0176% SSP (group T2), 0.026% SSP (group T3) and 0.0528% SSP (group T4), to have supplementary saponin at 0, 50, 75, and 150 ppm, respectively, for 42 days. Results: The results indicated that serum (p<0.001) and seminal plasma (p<0.05) testosterone level, semen volume (p<0.001), mass motility (p<0.001), and live spermatozoa count (p<0.001) was increased in groups T3 and T4 compared to T2 and control groups. Compared with control group, total sperm count was increased (p<0.001) and dead spermatozoa count was decreased (p<0.001) in SSP supplemented groups. Supplementation of SSP did not affected the quality of egg lay. Compared with control group, fertility (p<0.01) and hatchability (total eggs set and fertile eggs set) (p<0.001) were significantly improved in SSP supplemented groups with the highest improvement in T3 treatment group. Embryonic death was decreased (p<0.001) in SSP supplemented groups compared to control; lowest embryonic death was recorded in T3 treatment group. Conclusion: Thus, it was concluded that dietary supplementation of 0.026% SSP (saponin equivalent 75 ppm) improved the reproductive performance of broiler breeders.

Effect of Light Transmittance Control on the Root Yield and Quality during the Growing Season of Panax ginseng (생육시기별 광량조절이 인삼의 수량 및 품질에 미치는 영향)

  • Cheon, Seong-Ki;Lee, Tae-Su;Yoon, Jong-Hyuk;Lee, Sung-Sik;Mok, Sung-Kyun
    • Journal of Ginseng Research
    • /
    • v.28 no.4
    • /
    • pp.196-200
    • /
    • 2004
  • This study was conducted to compare the root weight, yield, quality of fresh and red ginseng roots and crude saponin content in roots between fixing light transmittance(Control) and changing light transmittance(C.L.T.) during the ginseng growing seasons. The root weight in C.L.T. was higher than control by $35{\%}$ in early growth stage, $28{\%}$ in middle growth stage and $26{\%}$ in late growth stage in 6 years old ginseng plant. Root yield per 10a in C.L.T. was increased about $40{\%}$ as compared with that of control, also 1st and 2nd grade of fresh ginseng roots in C.L.T. was higher $(50.3{\%})$ compared with that $(12.9{\%})$ of control. The specific gravity of ginseng roots grown under the C.L.T. was exhibited the sig­nificant difference than control during the growing season in 4 and 6 years old ginseng plants. Red ginseng quality in C.L.T. was not only improved remarkably due to the increasement of heaven and earth grade red ginseng but also increased in crude saponin content than control. Therefore it needs to change the light transmittance(increasing light dur­ing low temperature periods and decreasing light during high temperature period) during the growing season for high yield and good qualities of ginseng roots.

Effects of Acupuncture, Electro-acupuncture, Low Level He-Ne Laser Therapy at Oe-gwan($TE_5$) ${\cdot}$ Chogimup ($GB_{41}$) on L5 Spinal Nerve Ligation Model in Rats (건측(健測) 취혈(取穴) 다종(多種) 침자법(鍼刺法)이 백서(白鼠)의 신경병리성(神經病理性) 동통(疼痛)에 미치는 영향)

  • Jung, Jung-Hee;Cho, Myung-Rae;Wei, Tung-Sheun;Ryu, Chung-Ryeol
    • Journal of Acupuncture Research
    • /
    • v.24 no.5
    • /
    • pp.137-150
    • /
    • 2007
  • Objectives : To find effects of acupuncture, electro-acupuncture, low level He-Ne laser therapy(LLLT) at $TE_5$, $GB_{41}$ in the neuropathic pain. We made experiment on rats ligated L5 spinal nerve like general herniation of nucleus pulposus(HNP). Methods : A model of neuropathic pain was made by isolating Left 5th lumbar spinal nerve of rats. Three days after the neuropathic surgery, acupuncture and LLLT, electro-acupuncture was injected at $TE_5$, $GB_{41}$ one time a day for a week. Each group was divided two. one is opposite side performed the surgery which is right, another is left side performed the surgery. After that, the author examined the withdrawal response of neuropathic rats' legs by van Frey filament and acetone stimulation. And also the author examined c-Fos, Nociceptin and KOR-3 in the midbrain central gray of neuropathic rats. Results : As we have observed the effect of mechanical allodynia, LT-R group were diminished on 6th day compared with control group, EA-L group, EA-R group and LT-L group were diminished on 7th day compared with control group. As we have observed the effect of cold allodynia, EA-R group were diminished on 6th day, 7th day compared with control group. As we have observed the effect of activity of c-Fos in the central gray part, EA-R group and LT-R group were diminished compared with control group. As we have observed the effect of activity of Nociceptin in the central gray part, EA-R group were a little increased compared with control group but it is not reliability. As we have observed the effect of activity of KOR-3 in the central gray part, EA-R group were significantly increased compared with control group. Conclusions : We have noticed that effect of acupuncture at opposite side of sickness and powerful stimulation could be more effective, because of EA-R group have more controllable effect all test we have done on the other hand EA-L group have only effect on mechanical allodynia. This study can be used in clinical therapy for neuropathic pain. But it is not reliability that Nociceptin have effectively to control pain. Therefore We have to follow up about that.

  • PDF