• Title/Summary/Keyword: center pipe

Search Result 463, Processing Time 0.027 seconds

The Effect of Temperature on Aluminum Oxide and Chilled Mirror Dew-point Hygrometers (산화 알루미늄 및 냉각거울 노점계의 온도 의존성에 관한 연구)

  • Kim, Jong Chul;Choi, Byung Il;Woo, Sang-Bong;Kim, Yong-Gyoo;Lee, Sang-Wook
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.50-55
    • /
    • 2017
  • The measurement of absolute humidity of gases is essential in many industries. The effect of temperature on aluminum oxide and chilled mirror dew-point hygrometers is investigated. The temperature of laboratory, pipe line, and sensor is varied and the dew point is measured by two different aluminum oxide hygrometers. In all cases, the dew point of hygrometers is increased as the temperature is elevated. The reason behind this observation is due to desorption of water from the inside of pipe line and/or sensor surroundings at elevated temperature that result in the increase of the absolute humidity. Moreover, the sensor itself shows a certain degree of temperature dependency in sensing the humidity especially at low temperature. It is also studied that chilled mirror dew-point hygrometer may indicate a higher dew point than the reference at high temperature because the cooling capability of mirror is decreased at high temperature. Our study will provide evidences in the incorporation of the temperature effect as uncertainty factors in the standard calibration procedure for dew point hygrometers.

A Study on Gas-Liquid Contact in a Perforated Plate-Type $SO_2$ Absorber at Flooding Conditions

  • Han, Seung-Ho;Soowoo Kwon;Sangwon Jung;Jaehyuk Junk;Yang, Chang-Ryung;Carl Weilert
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.17-28
    • /
    • 1999
  • Gas-liquid contact tests above a perforated-plate were conducted with air and water at flooding gas-flow conditions in order to study two-phase flow characteristics in a limestone-gypsum SO2 absorber. Gas layers were in the form of air pockets and confined to the limited areas around each duct pipe, while the remaining tary area were in the wet condition. The liquid above the tray was always in the flooded and even fluidized conditions at gas flows over the range studied, although vigorous bubbly or churn-turbulent two-phase regime was only observed in the immediate vicinity of the gas hole exit at low gas loads. The froth zone was extremely active to provide intimate contact between gas and liquid so that the necessary mass transfer operation can take place, which is the primary purpose of high-performance SO2 absorbers. Howefer, the absorber $\Delta$P was 250mmH2O for the initial water level at 150mm, which is an important issue to be resolved for economical operation of the SO2 absorber. It was seen in the liquid level-and gas flow-transient tests that changes in the absorber liquid inventory were much more pronounced for intimate gas-liquid contact than changes in the gas flow. Based on the 4- and 8-duct pipe test results, grouping the duct pipes near the center of the test tray seemed to promote better recirulation of liquid from gas-liquid contact zone back to the reaction tank so that the absorbed SO2 can be neutralized.

  • PDF

Three-dimensional dynamics of vortex-induced vibration of a pipe with internal flow in the subcritical and supercritical regimes

  • Duan, Jinlong;Chen, Ke;You, Yunxiang;Wang, Renfeng;Li, Jinlong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.6
    • /
    • pp.692-710
    • /
    • 2018
  • The Three-dimensional (3-D) dynamical behaviors of a fluid-conveying pipe subjected to vortex-induced vibration are investigated with different internal flow velocity ${\nu}$. The values of the internal flow velocity are considered in both subcritical and supercritical regimes. During the study, the 3-D nonlinear equations are discretized by the Galerkin method and solved by a fourth-order Runge-Kutta method. The results indicate that for a constant internal flow velocity ${\nu}$ in the subcritical regime, the peak Cross-flow (CF) amplitude increases firstly and then decrease accompanied by amplitude jumps with the increase of the external reduced velocity. While two response bands are observed in the In-line (IL) direction. For the dynamics in the lock-in condition, 3-D periodic, quasi-periodic and chaotic vibrations are observed. A variety of CF and IL responses can be detected for different modes with the increase of ${\nu}$. For the cases studied in the supercritical regime, the dynamics shows a great diversity with that in the subcritical regime. Various dynamical responses, which include 3-D periodic, quasi-periodic as well as chaotic motions, are found while both CF and IL responses are coupled while ${\nu}$ is beyond the critical value. Besides, the responses corresponding to different couples of ${\mu}_1$ and ${\mu}_2$ are obviously distinct from each other.

A Experiment Study on Selection the Optimal Condition for GMA Root-pass Welding in Overhead and Vertical Position (GMA 위보기 및 수직자세 초층용접 최적조건 선정에 관한 실험적 연구)

  • Kim, Ji-Sun;Kim, In-Ju;Kim, Ill-Soo
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.42-48
    • /
    • 2012
  • Due to increase in demand of stable and long pipelines in natural gas industry, wide range of researches are being performed on automation welding to improved welding quality with respect to weld process parameters in real time measurement. In particular, the coupling between the pipe manufacturing process and location of the weld seam, the measured size of the gap that exists in the weld position and the weld angle depending on whether the movement of molten weld. This is due to absence of controlling welding penetration position, depending on the required size of the angle of the setting. In addition, the optimum welding conditions must be considered while selecting, the correlation between these variables and the systematic correlation has not yet been identified. Therefore, in most welded pipe root-pass weld solely depends on the experience of workers in relation to secure a stable weld quality. In this study, automation welding system is implemented to select a suitable root-pass STT (Surface Tension Transfer) welding method using the optimal welding conditions. To successfully accomplish this objective, there were various welding conditions used for welding experiment to confirm that the assessment required for construction through the pipe and automatic welding process is proposed to optimize this plan.

Mis-Match Limit Load Analyses and Fracture Mechanics Assessment for Welded Pipe with Circumferential Crack at the Center of Weldment (용접부 중앙에 원주방향균열이 있는 배관에 대한 강도불일치 한계하중 해석 및 파괴역학 평가)

  • Song, Tae-Kwang;Jeon, Jun-Young;Shim, Kwang-Bo;Kim, Yun-Jae;Kim, Jong-Sung;Jin, Tae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.19-26
    • /
    • 2010
  • In this paper, limit load analyses and fracture mechanics analyses were conducted via finite element analyses for the welded pipe with circumferential crack at the center of the weldment. Systematic changes for strength mismatch ratio, width of weldment, crack shape and thickness ratio of the pipe were considered to provide strength mismatch limit load. And J-integral calculations based on reference stress method were conducted for two materials, stainless steel and ferritic steel. Reference stress defined by provided strength mis-match limit load gives much more accurate J-integral.

PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method (3차원 곡관에서의 굴절률 일치법을 이용한 맥동 유동의 PIV 측정)

  • Hong, Hyeon Ji;Ji, Ho Seong;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.511-517
    • /
    • 2016
  • Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent $10^{\circ}$ from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer (열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석)

  • Choi, Myoung-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This paper numerically examines, straight and twisted electrical heat trace installations for their anti-freezing effects on water inside a pipe. The unsteady incompressible Navier-Stokes equations coupled with an energy equation were solved to compare the two installation methods. The heat conduction of the pipe with a heat source interacts with the natural convection of the water, and the conjugate heat transfer was considered using a commercial code (ANSYS-FLUENT) based on a SIMPLE-type algorithm. Numerical experiments, were done to investigate the isotherms and the vector fields in the water region to extract the evolutions of the minimum and maximum temperatures of the water inside the pipe. There was no substantial difference in the anti-freezing effects between the straight and twisted. Therefore, the straight installation is recommended after considering the damage and short circuit behavior of the electrical heat trace.

A study on deformation characteristics of fire pipe with sharp change by using Finite Element Method (유한요소해석을 이용한 소방용 배관의 형상변화에 따른 변형특성에 관한 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.308-311
    • /
    • 2010
  • 본 연구에서는 유한요소해석을 통하여 나선 주름모양 소방용 파이프를 모델링하여 각 모델간의 발생응력과 변형량을 상호간에 비교 검토하여 강도 안전성이 우수한 배관시스템의 설계 최적화를 하기 위함이 연구의 목적이다.

  • PDF

A numerical study on deformation characteristics of bracket for fire pipe system (소방 배관용 브라켓의 변형특성에 관한 수치적 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.312-318
    • /
    • 2010
  • 본 연구에서는 배관계에 가해진 압력으로 인하여 변형된 배관에 의하여 영향을 받는 브라켓에 대하여 여러 가지 형상으로 모델링하여 유한요소해석을 통하여 브라켓의 형상변화가 변형특성에 미치는 영향을 고찰 하였고, 배관시스템의 브라켓의 강도 안전성을 확보하기 위하여 산업공학에서 쓰였던 다구찌방법을 도입하여 최적화 설계를 하는 것이 본 연구의 목적이다.

  • PDF