• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.037 seconds

The fabrication of 2GHz Circulator using $Y_{3-2x}$ $Ca_x$S $n_x$F $e_{3.5}$A $l_{1.5}$ $O_{12}$ Garnet ( $Y_{3-2x}$ $Ca_x$S $n_x$F $e_{3.5}$A $l_{1.5}$ $O_{12}$ 가네트 자성체를 이용한 2GHz 대 서큘레이터 구현)

  • 박정래;김태홍;전동석;한진우
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.12
    • /
    • pp.14-21
    • /
    • 1997
  • This study was conducte dto fabricate 2GHz circulator using Ca,Sn substituted UIG(yttrium iron garnet)ceramics. When the electric, magnetic and microwave properties were measured in Ca, Sn substituted YIG, the measured perimittivity and perfmeability in microwave frequencies were 16.25, 0.8964. For $Y_{2.4}$C $a_{0.3}$A $n_{0.3}$F $e_{3.5}$A $l_{1.5}$ $O_{12}$ garnet ceramics sintered at 1400.deg. C, the ferrimagnetic resonance line width (.DELTA.H) at 10GHz was 53 Oe and saturation magnetization was 375G. The strip-line circulator was simulated with 3-D FEM (finite element method) software and designed at the center frequency of 2GHz. The fabricated strip-line junction circulator using above YIG ceramics had insertion loss of 1.271dB, return loss of 23.843dB, isolation of 21.751dB at the center frequency 1.855GHz.z.z.z.z.z.z.

  • PDF

Screening panoramic radiographs in a group of patients visiting a Health Promotion Center

  • Lee Jae-Seo;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.199-202
    • /
    • 2005
  • Purpose : To report the incidence of radiological findings from screening panoramic radiographs and verify the validity of the panoramic radiography for screening purposes. Materials and Methods : Six thousand one hundred and sixty panoramic radiographs taken from the patients visiting the Health Promotion Center of CNUH were selected for this retrospective study. Panoramic radiographs were examined into the following pathologic conditions : the presence of periodontal bone loss, dental caries, periapical radiolucencies, retained roots, impacted supernumerary teeth, impacted third molars, odontoma, cystic lesions other than radicular cyst, sialoliths, and mixed radiolucent-radiopaque lesions. Number of pathologic conditions and Prevalence values were recorded. Results: The prevalences of pathologic conditions were $72.9\%$ of periodontal bone loss, $32.2\%$ of dental caries, $11.9\%$ of periapical radiolucencies, $10.8\%$ of retained roots, $0.4\%$ of root fracture, $1.0\%$ of impacted supernumerary teeth, $1.0\%$ of impacted third molars, $0.06\%$ of odontoma, $0.08\%$ of cystic lesion other than radicular cyst, $0.2\%$ of prolonged retention of deciduous tooth, $0.1\%$ of sialolith, and $0.04\%$ of mixed radiopaque and radiolucent lesion. Conclusion : Although the panoramic radiograph should not be used to replace intraoral radiographic and clinical examinations, this study showed that many dental pathologic conditions could be detected on panoramic radiographs. The panoramic radiograph might serve as a diagnostic aid in dental health evaluation programs.

  • PDF

축류회전차 익말단 틈새유동에 대한 수치해석

  • No, Su-Hyeok;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.336-345
    • /
    • 1998
  • The substantial loss behind axial flow rotor was generated by wake, various vortices in the hub region and the leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip was one of the main causes of the reduction of performance, the generation of noise and the aerodynamic vibration in rotor downstream. In this study, the three-dimensional flowfields in an axial flow rotor for various tip clearances were calculated, and the numerical results were compared with the experimental ones. The numerical technique was based on SIMPLE algorithm using standard k-.epsilon. model (WFM). Through calculations, the effects of the tip clearance on the overall performance of rotor and the loss distributions, and the increase in the displacement, momentum, and blade-force-deficit thickness of the casing wall boundary layer were investigated. The mass-averaged flow variables behind rotor agreed well with the experimental results. The presence of the tip leakage vortex behind rotor was described well. Although the loci of leakage vortex by calculation showed some differences compared with the experimental results, its behavior for various tip clearances was clarified by examining the loci of vortex center.

A Study on Ignition Probability and Combustion Characteristics of Low Pressure Direct Injection LPG according to a Function of Ambient Condition (분위기 조건 변화에 따른 저압 직접분사식 LPG의 점화성 및 연소특성 연구)

  • Chung, Sung-Sik;Hwang, Seong-Ill;Yeom, Jeong-Kuk;Jeon, Byong-Yeul
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.32-42
    • /
    • 2016
  • Under part load condition of spark-ignition engine, pumping loss had great effect on engine efficiency. To reduce pumping loss, the study designed spark-ignited engines to make direct spray of gasoline to combustion chamber. In spark-ignited direct-injection engines, ignition probability is important for successful combustion and flame propagation characteristics are also different from pre-mixed combustion. This study designed a visualization testing device to study ignition probability of spark-ignited direct-injection LPG fuel and combustion flame characteristics. This visualization device consists of combustion chamber, fuel supply system, air supply system, electronic control system and data acquisition system. Ambient pressure, ambient temperature and ambient air flow velocity are important parameters on ignition probability of LPG-air mixture and flame propagation characteristics, and the study also found that sprayed LPG fuel can be directly ignited by spark-plug under proper ambient conditions. To all successful cases of ignition, the study recorded flame propagation image in digital method through ICCD camera and its flame propagation characteristics were analyzed.

Prolyl Endopeptidase Inhibitory Activity of 6-O-Palmitoyl L-Ascorbic Acid

  • Park, Yoon-Seok;Paik, Young-Sook
    • Journal of Applied Biological Chemistry
    • /
    • v.49 no.3
    • /
    • pp.110-113
    • /
    • 2006
  • Prolyl endopeptidase (PEP, EC 3.4.21.26, also referred to as prolyl oligopeptidase) degrades proline containing, biologically active neuropeptides such as vasopressin, substance P and thyrotropin-releasing hormone by cleaving peptide bonds on carboxyl side of prolyl residue within neuropeptides of less than 30 amino acids. Evaluation of PEP levels in postmortem brains of Alzheimer's disease patients revealed significant increases in PEP activity. Therefore, a specific PEP inhibitor can be a good candidate of drug against memory loss. Upon our examination for PEP inhibitory activity from micronutrients, ascorbic acid (vitamin C) showed small but significant PEP inhibition (13% PEP inhibition at $8{\mu}g{\cdot}ml^{-1}$). Palmitic acid showed almost no PEP inhibition. However, 6-O-palmitoyl ascorbic acid ($\underline{1}$) showed 70% PEP inhibition at $8{\mu}g{\cdot}ml^{-1}$ indicating that hydrophobic portion of the compound $\underline{1}$ may facilitate the inhibitory effect. $IC_{50}$ value of compound $\underline{1}$ was $12.6{\pm}0.2{\mu}M$. The primary and secondary Lineweaver Burk and Dixon plots for compound $\underline{1}$ indicated that it is a non-competitive inhibitor with inhibition constant (Ki) value of $23.7{\mu}M$.

Design and implementation of dual-mode cavity filter with achebyshev response (체비셰프 응답을 갖는 이중모드 공동 공진기 필터의 설계 및 제작)

  • 김상철;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.2
    • /
    • pp.505-513
    • /
    • 1996
  • In this paper the dual-mode bandpass filters with a Chebyshev response are designed and manufactured at Ku-band as well as K-band. Manufactured filters are resonated by two independent orthogonal $TE_{113}$ circular-cavity modes and characterized by 4-pole Chebyshev function. One is operating at a center frequency of 12.5GHz with a bandwidth of 100MHz and the other, a center frequency of 19.25GHz with 120MHz, respectively. The measureed experimental results of a 12.5GHZ dual-mode filter ahve a 1.2dB intertion loss in the passband and 65dB out-of-rejection, and a 19.25GHz filter has a 1.55dB insertion loss and 70dB out-of-rejection. These experimantal results shoults show good agreements with the design specifications.

  • PDF

Propagation Characteristics from Ingested Sources in Human Body (인체 내부 소스에 의한 전파 특성)

  • Kim Bo-Mi;Kim Young-Sik;Kim Se-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.259-266
    • /
    • 2006
  • This paper presents the propagation characteristics from ingested sources in human body using the human model simulator. The simulator applies the FDTD method to the human data consisting of the human CAD and tissue data. After the accuracy of the simulator is verified, the received fields at one horizontal layer including the small intestine among the digestive organs are calculated in case that the electric field source is implanted in the center of the small intestine. The human propagation characteristics are illustrated by calculating the path loss per unit length according to various received positions from the simulated results.

A Method to Reduce Flow Depth of a Plate Heat Exchanger without a Loss of Heat Transfer Performance (판형 열교환기의 열전달성능 손실 없이 유동방향 길이를 축소하는 방법)

  • Song Gwi-Eun;Lee Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.129-136
    • /
    • 2006
  • Optimal design of an air-to-liquid finned plate heat exchanger is considered theoretically in this study. Based on existing correlations for the pressure loss and the heat transfer in channel flows, the optimal configuration of the plate heat exchanger including the optimal plate pitch and the optimal fin pitch is obtained to maximize the heat transfer within the limit of the pressure drop for a given flow depth of the plate heat exchanger. It is found that the optimal fin pitch is about one ninth of the optimal plate pitch. In the optimal configuration, the flow and thermal condition in the channels is just at the boundary between the laminar developing and laminar fully developed states. It is also found when reducing the flow depth of plate heat exchangers for compactness, the heat transfer performance can be maintained exactly the same if the geometric parameters such as the plate thickness, plate pitch, fin thickness, and fin pitch are reduced proportional to the square root of the flow depth as long as the flow keeps laminar within the heat exchangers.

Study on Numerical Model of Leakage Flow at Gap between Compartments in a Building (건축물 구획실간 틈새에서의 누설유동에 대한 수치모델 연구)

  • Kim, Jung-Yup;Kim, Ji-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.562-567
    • /
    • 2013
  • 1D-numerical analysis of the network algorithm with the orifice equation for the relationship between pressure difference and flowrate has been mostly used to analyse leakage flow at the gap. In this study, a 3D-numerical method applying momentum loss model to the gap region in the computational domain is represented to reflect effectively the effect of leakage flow by determining the proportion of pressure difference to air passage velocity. While the 3D-numerical method is verified through the computation of the two compartments model, the numerical analysis of the stack effect in a building stairway is performed. As the temperature of air outside drops, the pressure in the upper stairway and leakage flowrate through the gap in the door rise. The change of gap area does not have an effect on pressure in the stairway for the analysis conditions.

Ingestion of Korean Red Ginseng after Noise Exposure Can Potentiate Rapid Recovery of Hearing in Mice

  • Kang, Woo-Seok;Chung, Jong-Woo
    • Journal of Ginseng Research
    • /
    • v.34 no.4
    • /
    • pp.336-341
    • /
    • 2010
  • One mechanism of inner ear damage by noise-induced hearing loss (NIHL) is the production of reactive oxygen species (ROS). Because Korean red ginseng (KRG) has an anti-ROS effect in various tissues, KRG may have a role in preventing NIHL. A window period exists in which ROS formations continue after noise exposure, and further damage can be prevented by antioxidants. In this study, we aimed to investigate the effects of KRG after exposure to noise. KRG (200 mg/kg) was fed to mice for 3 days after noise exposure. The change in hearing level was analyzed by measuring the auditory brainstem response. To induce a temporary threshold shift (TTS) of hearing, mice were exposed to 110 dB white noise for 3 hours. Fast recovery of hearing was observed in mice fed KRG 1 hour and 1 day after noise exposure for 3 days. The expression of 8-oxoguanine was not observed in the inner ears of mice fed KRG 1 hour after noise exposure, but was evident in the stria vascularis of mice in the control group (noise exposure only). From this study, we conclude that KRG acted as an effective inhibitor of NIHL in TTS cases.