• Title/Summary/Keyword: cell controller

Search Result 372, Processing Time 0.033 seconds

A Vibration Control of the Strcture using Immune Response Algorithm (면역반응 알고리즘을 이용한 구조물의 진동제어)

  • 이영진;이권순
    • Journal of Korean Port Research
    • /
    • v.13 no.2
    • /
    • pp.389-398
    • /
    • 1999
  • In the biological immunity, the immune system of organisms regulates the antibody and T-cells to protect the attack from the foreign materials which are virus, germ cell, and other antigens, and supports their stable state. It has similar characteristics that has the adaptation and robustness to overcome disturbances and to control the plant of engineering application. In this paper, we build a model of the T-cell regulated immune response mechanism. We have also designed an immune response controller(IRC) focusing on the T-cell regulated immune response of the biological immune system that include both a help part to control the response and a suppress part to adjust system stabilization effect. We show some computer simulation to control the vibration of building structure system with strong wind forces excitation also demonstrate the efficiency of the proposed controller for applying a practical system even with existing nonlinear terms.

  • PDF

Development of Robust Algorithm to Eliminate Low Frequency Current Ripples in Fuel Cell Generation System (동적변화에 강인한 연료전지 발전시스템의 저주파 리플전류 제거 알고리즘 개발)

  • Kim, Jong-Soo;Kang, Hyun-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1720-1727
    • /
    • 2009
  • This paper presents that generation and propagation mechanism of low frequency current ripples generated by a rectification effect of an inverter in fuel cell generation system is analyzed. The ripple reduction methode using hardware components such as capacitors and inductors is examined to reduce low frequency current ripples. A new fast and robust low frequency current ripple elimination algorithm is then proposed to incorporate a single loop current controller, which directly controls fuel cell current, without any extra hardware. The proposed algorithm can completely eliminate this current ripple as well as an overshoot or undershoot is significantly reduced. And the de link voltage and output current are well regulated by inverter controller. The validity of proposed algorithm is verified both computer simulation using PSIM 6.0 and experiment with a 1kW laboratory prototype.

Design and Analysis of Cell Controller Operation for Heat Process (열공정에 대한 셀 콘트롤러 운영의 설계와 해석)

  • So, Ye In;Jeon, Sang June;Kim, Jeong Ho
    • Journal of Platform Technology
    • /
    • v.8 no.2
    • /
    • pp.22-31
    • /
    • 2020
  • The construction and operation of industrial automation has been actively taking place from manufacturing plan to production for improving operational efficiency of production line and flexibility of equipment. ISO/TC184 is standardizing on operating methods that can share information of programmable device controllers such as PLC and IoT that are geographically distributed in the production line. In this study, the design of the cell controller consists of PLC group and IoT group that perform signals such as temperature sensors, gas sensors, and pressure sensors for thermal processes and corresponding motors or valves. The operation and analysis of the cell controller were performed using SDN(Software Defined Network) and the three types of process services performed in thermal processes are real-time transmission service, loss-sensitive large-capacity transmission service, and normal transmission service. The simulation result showed that the average loss rate improved by about 17% when the traffic increased before and after the application of the SDN route technique, and the delay in the real-time service was as low as 1 ms.

  • PDF

Maximum Power Point Tracking Control of Photovoltaic Array Using Fuzzy control (퍼지제어에 의한 태양전지의 최대출력점 추적제어)

  • Kim, Jong-Su;Kim, Dae-Gwun;Kim, Sung-Nam;Lee, Seung-hwan;Kim, Yong-Joo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2262-2264
    • /
    • 1997
  • In this paper, Maximum Power Point Tracking Method using Fuzzy controller is proposed to improve energy conversion efficiency. The solar cell has an optimum operating point to be able to get maximum power. To obtain maximum power from photovoltatic any, photovoltatic power system usually requires maximum power point tracking controller. The output characteristics of solar cell are nonlinear. To obtain maximum power from photsvoltatic array, the fuzzy controller only uses the output power. Therefore this control method is easy to implement to real system.

  • PDF

Flow Control for Fuel Cell System with DSP Controller (DSP Controller를 적용한 연료전지 시스템의 유량 제어)

  • Shin, Bum-Su;Choi, Dong-Min;Han, Se-Young;Lee, Ho-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.184-187
    • /
    • 2007
  • 본 논문은 DSP Controller를 적용한 연료전지시스템의 유량제어에 관한 논문이다. 그리고 이 연구에서 사용된 시스템은 1kW급 계통연계 연료전지 시스템이다. 이 연료전지 시스템이 안정적으로 전원을 공급할 수 있도록 시스템에서 요구하는 공기 유량을 정확히 공급하도록 제어하는 것이 본 연구의 목적이다. 이 목적을 이루기 위해 공기 공급 장치에 PID 제어기를 설계하여 적용하였다. PID 제어기의 Gain값은 지글러 니콜스 Tuning 방식으로 정하였다. 이 제어기를 적용하여 실험한 결과, 적용 전 상태와 비교하면 맥동이 30% 저감하였고, 정상상태 오차가 제거되어 온도 변화와 같은 외란과 상관없이 정확한 요구 공기 유량을 공급함을 확인할 수 있었다. 그리고 부하가 변동함에 따라 해당 요구 공기 유량이 바뀔 때 1초 내에 그 요구 공기 유량을 추종하여 스택이 안정적으로 운전될 수 있도록 하였다.

  • PDF

A Quantitative Analysis of the Nonlinearity of Fuzzy Logic Controller (퍼지논리 제어기의 비선형성의 정량적 해석)

  • Lee, Chul-Heui;Seo, Seon-Hak
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.231-237
    • /
    • 1996
  • In this paper, the nonlinear I/O characteristic of fuzzy logic controller is analyzed by using cell concept. Sources of the nonlinearity in a fuzzy logic controller include the fuzzification, the fuzzy reasoning and the defuzzification. A closed form expression for the defuzzified output is derived in case of a fuzzy logic controller with two inputs, triangular memberships, MacVicar-Whelan type linguistic rules, and direct fuzzy reasoning. As a result, it is shown that fuzzy logic controller is a nonlinear controller. Also its nonlinearity is analyzed with respect to the conventional PID control and the sliding mode control.

  • PDF

Design of Nonlinear PID Controller Based on Immune Feedback Mechanism (면역 피드백 메카니즘에 기초한 비선형 PID 제어기 설계)

  • Park Jin-Hyun;Choi Young-Kiu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.3
    • /
    • pp.134-141
    • /
    • 2003
  • PID controllers with constant gains have been widely used in various control systems due to its powerful performance and easy implementation. But it is difficult to have uniformly good control performance in all operating conditions. In this paper, we propose a nonlinear variable PR controller with immune feedback mechanism. An immune feedback mechanism is based on the functioning of biological T-cells, they include both an active term, which controls response speed. and an inhibitive term, which controls stabilization effect. Therefore, the proposed nonlinear PID controller is based on immune responses of biological. immune feedback mechanism which is the cell mediated immunity and In order to choose the optimal nonlinear PID controller games, we also propose the tuning algorithm of nonlinear function parameter in immune feedback mechanism. To verify performance of the proposed algorithm, the speed control of nonlinear DC motor are performed. Front the simulation results, we have found that the proposed algorithm is more superior to the conventional constant fain PID controller.

Development of Power Conditioning System for High Power Fuel Cell System (대용량 연료전지 발전시스템용 전력변환기 개발)

  • Kang, Ho-Hyun;Lee, Jin-Hee;Baek, Seung-Taek;Jung, Hong-Ju;Chung, Joon-Mo;Suh, In-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.153-156
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF

The Controller Design of Bi-directional DC-DC Converter for a Fuel Cell Energy Storage System (연료전지용 커패시터 충.방전을 위한 양방향 DC-DC 컨버터 제어기 설계)

  • Kim, Seung-Min;Yang, Seung-Dae;Choi, Ju-Yeop;An, Jin-Woong;Lee, Sang-Chul;Lee, Dong-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.222-228
    • /
    • 2012
  • This paper presents a design and simulation of bi-directional DC/DC boost converter for a fuel cell system. In this paper, we analyze the equivalent model of both a boost converter and a buck converter. Also we propose the controller of bi-directional DC-DC converter, which has buck mode of charging a capacitor and boost mode of discharging a capacitor. In order to design a controller, we draw bode plots of the control-to-output transfer function using specific parameters and incorporate 3pole-2zero compensator in a closed loop. As a result, it has increased PM(Phase Margin) for better dynamic performance. The proposed bi-directional DC-DC converter's 3pole-2zero compensation method has been verified with computer simulation and simulation results obtained demonstrates the validity of the proposed control scheme.

  • PDF

Development of Power Conditioning System for High Power Fuel Cell System (대용량 연료전지 발전시스템용 전력변환기 개발)

  • Lee, Jin-Hee;Baek, Seung-Taek;Jung, Hong-Ju;Kang, Ho-Hyun;Chung, Joon-Mo;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.530-532
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF