• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.029 seconds

A Study on the Improvement of Life Safety Code for Logistics Warehouse Facilities (물류창고 시설의 인명안전기준 개선 방안에 관한 연구)

  • Kim, Yun-Seong;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.98-99
    • /
    • 2021
  • The number of fires in the Korean distribution warehouse increased by about 350 from 1,070 in 2014 to 1,416 in 2020. In addition, the fire load increases with the scale of the distribution warehouse, and even if the automatic sprinkler operates, there is a limit to the direct intrusion of the water source into the ignition source, and the detector is often installed on a high ceiling. The sensing time is often delayed. In order to improve the fire safety of such distribution warehouses, the US NFPA stipulates in detail the contents related to the facility, such as sprinkler water discharge standards, rack-type warehouse installation height restrictions, and regulations on collection and equipment. However, in Japan, the goods loaded inside the distribution warehouse are not classified in detail, and it is considered that the fire safety for the distribution warehouse is low due to the relaxation regulations of the fire prevention section. Therefore, in this study, common problems are classified into material, spatial, and safety management characteristics through the cases of distribution warehouse fires that occurred in Korea and abroad, and the problems related to distribution warehouses in Korea and abroad are compared and analyzed. And present basic materials for improving the life safety standards of future distribution warehouse facilities.

  • PDF

Development of Process Planning Model for Asbsestos Dismantling Work Based on Performance Risk (석면해체 공사의 작업 위험성 기반 공정 계획 모델 개발)

  • Lee, Su-Min;Noh, Jae-Yun;Han, Seung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.71-72
    • /
    • 2023
  • Asbestos is a durable and heat-resistant building material used in various building materials such as slate, ceiling tex, and spray paint. It has been banned since 2009 after found to be a first-class carcinogen that causes various cancers and asbestos lung disease. Since workers are likely to be exposed to asbestos in the process of dismantling and removal of asbestos-made building materials and facilities, laws and work standards are proposed by the Ministry of Employment and Labor to ensure the safety of asbestos dismantling work. In addition, prior studies on exposure levels and analysis methods have been conducted in this regard mainly for residents. However, the relation between the results of the risk assessment of the process conducted during the asbestos investigation and the work is still ambiguous for the safety of workers. Therefore, this study proposes a process model development methodology that considers work risk based on the results of a survey from asbestos dismantling companies.

  • PDF

Critical buckling coefficient for simply supported tapered steel web plates

  • Saad A. Yehia;Bassam Tayeh;Ramy I. Shahin
    • Structural Engineering and Mechanics
    • /
    • v.90 no.3
    • /
    • pp.273-285
    • /
    • 2024
  • Tapered girders emerged as an economical remedy for the challenges associated with constructing long-span buildings. From an economic standpoint, these systems offer significant advantages, such as wide spans, quick assembly, and convenient access to utilities between the beam's shallow sections and the ceiling below. Elastic-local buckling is among the various failure modes that structural designers must account for during the design process. Despite decades of study, there remains a demand for efficient and comprehensive procedures to streamline product design. One of the most pressing requirements is a better understanding of the tapered web plate girder's local buckling behavior. This paper conducts a comprehensive numerical analysis to estimate the critical buckling coefficient for simply supported tapered steel web plates, considering loading conditions involving compression and bending stresses. An eigenvalue analysis was carried out to determine the natural frequencies and corresponding mode shapes of tapered web plates with varying geometric parameters. Additionally, the study highlights the relative significance of various parameters affecting the local buckling phenomenon, including the tapering ratio of the panel, normalized plate length, and ratio of minimum to maximum compressive stresses. The regression analysis and optimization techniques were performed using MATLAB software for the results of the finite element models to propose a separate formula for each load case and a unified formula covering different compression and bending cases of the elastic local buckling coefficient. The results indicate that the proposed formulas are applicable for estimating the critical buckling coefficient for simply supported tapered steel web plates.

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Architectural Acoustic Performance Renovation of the Large Gymnasium using Acoustic Simulation (음향시뮬레이션을 이용한 대형 실내체육관의 건축음향성능 개선에 관한 연구)

  • Yun, Jae-Hyun;Kim, Jae-Soo
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2008
  • In this study, an analysis is carried out on the acoustic design for an indoor gymnasium scheduled to be built at Buan County, Chonbuk Province. By way of background, the study examines the case of a large-scale indoor gymnasium that has been constructed in the local area of Hangan-myeon. There are many examples whereby this gymnasium could be used not only as a sporting facility for the residents, but also as a multipurpose space for public performances such as leisure activities, lectures, assembling activities, theatre and concerts etc. In order to maximize the functional utilization of such an indoor gymnasium, it is important to simultaneously verify the acoustic capabilities of the space in terms of Definition of both Voice and Music. However, as a large-scaled athletic facility, the building was designed with a high ceiling-height to accommodate its functional characteristics. The space forms a Sound Focus whereby the sound is concentrated at a specific part, and because the vibration of sound is too loud due to its broad volume, acoustic defects arise such as a significant number of Echoes. Using this gymnasium as a precedent, this study proposes an acoustic design based on the drawings of the indoor gymnasium that is scheduled to be built at B County, Chonbuk Province. The gymnasium is equipped with an optimized acoustic condition passing through the Acoustic Simulation Phase. From the results of an Acoustic Simulation, we can design an indoor gymnasium that is equipped with a considerably satisfying and improved acoustic performance compared with the building before it was reformed. It is also considered that the use of such materials can fundamentally reduce construction costs and can improve acoustic performance, at the planning and design stages for similar sporting facilities in the future.

Mannheimiosis case in Hanwoo caused by heat stress (한우에서 고온스트레스에 의한 Mannheimiosis 발생 증례)

  • Lee, Jeong-Won;Shon, Ku-Rye;Jeong, Han-Sol;Ko, Won-Seok;Lim, Chae-Woong;Kim, Bum-Seok
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.3
    • /
    • pp.195-198
    • /
    • 2015
  • Mannheimia haemolytica is an opportunistic bacterium that is widely recognized among the bovine respiratory disease (BRD) complex in cattle. Five Hanwoo with a history of fever, anorexia and dyspnea were died within 2 days in a the middle of summer. Four cattle were pregnant. The cattle house were located in mountainous area but the window for air ventilation was open only one side. In addition, the fecal material for fermentation was located indoor. Air ceiling fan did not work. The indoor temperature was $40^{\circ}C$. After working on air fan, the indoor temperature was still $36^{\circ}C$. On necropsy, there was fibrinous pleuritis with a rich yellowish pleural fluids in the thorax. The cross-section of the lung showed lobar fibrinonecrotic pneumonia with expanded interlobular septa by edema and fibrin. Microscopically, parenchymal necrosis with dense layer of inflammatory cells were observed surrounding interlobular septum. Fibrin and inflammatory cells were filled in the alveoli. Bacteriological cultures of pulmonary tissue showed growth of M. haemolytica. This pneumonia case in Hanwoo suggests that environmental stressors such as high temperature, insufficient air ventilation, and pregnancy be the cause of mannheimoisis. Control of environmental stressor, such as temperature indoor is necessary to prevent BRD caused by M. haemolytica.

Explore Career Development of Female Recently Obtained Doctoral Degree in Education (신규 여성 박사들의 경력개발에 관한 탐색적 연구 -교육계열 전공자를 중심으로)

  • Kim, Hyosun
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.685-696
    • /
    • 2013
  • The purpose of the present study is to explore the career development barriers of female doctoral degree holders in education. The study occupied in-depth interview with 42 female doctoral degree holders in education. The results were as followed; First, academic advisor highly influenced the career development female doctoral degree holders through their academic activities. Second, they had experiences regarding glass ceiling effect in workplace. Third, marriage was a critical issue for both of the married and single female doctoral degree holders. Fourth, family and relatives' support positively impact on their career will, and also their strong career goal was beneficial way to break their career barriers. Also, the study suggested contextural factor was very significant on career behavior of female doctoral degree holders. Therefore, policy maker, scholars, and students should have strong attention to female students' career guidance and development in various way. The results of the study discussed in relation to the existing literature, with reference to women's career development and career barriers, and then implication for the future research were suggested.

The Characteristics of Chinese Traditionality Expression in View of Spatial Elements at Restaurants in Beijing Area (베이징지역 레스토랑 공간구성요소에 나타난 중국 전통성 표현 특성 연구)

  • Yuan, DanDan;Oh, Hye Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.163-171
    • /
    • 2016
  • The objectives of this study is to analyze the characteristics of Chinese traditionality expression at restaurants in Beijing area. 12 restaurants were selected and visited for the investigation research. The results were as follows. First, traditional reproduction was found mainly manifested through the reproduction of traditional ornaments, in particular, the facade and interior element ornaments. Second, Traditional transformation was mainly manifested in replacement material while changing the shape slightly, or to stretch or shorten prototype shape and other negative deformation methods which did not largely out of the scope of traditional reproduction. Third, Traditional reinterpretation was expressed by abstract, symbol or metaphor on designs, usually people can not directly recognize the traditional archetype. When compare with traditional reproduction or traditional transformation, traditional reinterpretation was relatively fewer, however, in this study the traditional reinterpretation and traditional transformation have same numerical result. Reinterpretation as a positive performance method of traditional modernized, it was encouraging the phenomenon, especially in the ceiling design. Chinese traditional cloud patterns have been three-dimensional and diversification of use. And in the wall design, traditional elements have been extremely simplistic or adopted a wide variety of traditional elements, it may be preferred in diversity. In addition, furniture was tinge traditional elements in modern form, lighting was added symbolize color or picture on the traditional lighting which shape was simplified to emphasize space's traditional. But the facade, sign board, floor, and window element seems the range of variation was not wild, promote more use the positive traditional reinterpretation method.

Indoor Position Estimation Using Stereo Image Sensor and LEDs (스테레오 이미지 센서와 LED 조명을 이용한 실내 측위)

  • Moon, Myoung-Geun;Choi, Su-Il
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.11
    • /
    • pp.755-762
    • /
    • 2014
  • In recent year, along with the rapid development of LED technology, many applications using LEDs with Visible Light Communication(VLC) have been researched. Since it is easy to provide LOS communication environment along with cheap deployment cost, the indoor positioning system based on VLC has been actively studied. In this paper, we propose an accurate indoor positioning algorithm using a stereo image sensor and white-light LEDs with the visible light communication. Indoor white-light LEDs are located at the ceiling of a room and broadcast their position information by VLC technology. Mobile receiver with stereo image sensor receives LED position information by VLC and estimates its position and angle information. Simulation results are given to show the efficiency of proposed indoor positioning algorithm.

Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type (고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Kim, Yong-Kab;Park, Dae-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Currently, road lightings are installed with less than 400W of existing metal halide lamps. These road lightings are being replaced by energy-saving lightings. Induction lamps are expected to be more actively replaced with targets for tunnel lighting and high ceiling lighting. Therefore, it is necessary to develop high efficiency, high power induction lamps system. In this study, the gas type & pressure, amalgam type were designed for the high power of the induction lamps. And induction lamp system was optimized through electrical, optical characteristics analysis. It is optimized to the gas pressure 300~350 [mmHg] for the discharge tube of high power induction lamp and ferrite core. The driving circuit matching was completed with a induction lamp using indium amalgam. The rated power consumption of the induction lamp was optimized with 250 W (rated ${\pm}10%$)