• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.023 seconds

Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System (돈사용 환기팬을 위한 돈사 내 온도 분포 특성)

  • Kim, Hyeon-Tae;Kim, Woong
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

Development of New Micropiling Technique and Field Installation (신개념 마이크로파일 개발 및 현장시험시공)

  • Choi, Chang-Ho;Goo, Jeong-Min;Lee, Jung-Hoon;Cho, Sam-Deok;Jeong, Jae-Hyeong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.571-578
    • /
    • 2009
  • Recently, micropiling techniques are increasingly applied in foundation rehabilitation/underpinning and seismic retrofitting projects where working space provides the limited access for conventional piling methods. Micropiling techniques provide environmental-friendly methods for minimizing disturbance to adjacent structures, ground, and the environment. Its installation is possible in restrictive area and general ground conditions. The cardinal features that the installation procedures cause minimal vibration and noise and require very low ceiling height make the micropiling methods to be commonly used for underpin existing structures. In the design point of view, the current practice obligates the bearing capacity of micropile to be obtained from skin friction of only rock-socketing area, in which it implies the frictional resistance of upper soil layer is ignored in the design process. In this paper, a new micropiling method and its verification studies via field installation are presented. The new method provides a specific way to grout bore-hole to increase frictional resistance between surrounding soil and pile-structure and it allows to consider the skin friction of micropiles for upper soil layer during design process.

  • PDF

Architectural Acoustics Design of multipurpose Auditorium in S-high school (S고등학교(高等學校) 다목적(多目的) 강당(講堂)의 건축음향설계(建築音響設計))

  • Ju, Duck-Hoon;Yun, Jae-Hyun;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.436-440
    • /
    • 2008
  • Among those various facilities attached to the school building, the Auditorium is being utilized for not only the Exercise Activity but also for many purposes such as Culture, Public Performance, Education, Assembly and so on. In order to utilize in maximum such function of the multipurpose auditorium, an adequate acoustic design with regard to the Clarity of Voice and Music in accordance with its use-purpose should be accompanied. However, as the most part of multipurpose auditoriums is designed with high ceiling-height by its peculiar character, and due to use of the material of strong reflexibility, it is appearing the defect that excessively exposes the reverberation of sound. In order to make out an optimal acoustic condition within the broad space such as an auditorium, the acoustic characteristics must be considered from the planning stage, however in the most case, those acoustic problems are being settled through the repair works after construction. On such viewpoint, this Study intends to analyze the room acoustic characteristics from the planning stage using a computer simulation based on the blueprint of multipurpose auditorium in S High School located in Gwangju. It is considered that the material analyzed in such way could be practically applied as a fundamental material enables to improve the acoustic capability when a similar broad space is planned hereafter.

  • PDF

A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System - (에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 -)

  • Choi, Young-Ho;Shim, Woo-Gab
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.

Scale Model Experiment on Daylighting of Differentiated Glazing System (축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험)

  • Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

A Study on Illumination Distribution of Blackboard on Elementary, Junior and Senior High School (초.중.고교의 흑판조도분포에 관한 연구)

  • Kim, Dong-Jin;Choi, Jae-Myoung;Kim, Tae-Hyoun;Lee, Hyoun-Jae;Lee, Byoung-Gi;Park, Tong-wha
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1770-1772
    • /
    • 1998
  • This study is concluded under by investigation about the lighting environment on a blackboard in elementary, middle, high school of inchon metropolitan. 1. The illumination was approximated to standard value in the side of quantity by the result of the Mimistry of Education's command. However, the uniformity of illuminescence was relatively increased. 2. In order to raise the blackboard lighting, we installed local lighting fixture for blackboard but most of schools are directly adopted to the way of sticking to the blackboard and the lower part of the blackboard is not effective. So that it is desirable of teacher and students to put the local lighting in front of the higher part of the blackboard or install in setting the perfect diffusion light from the ceiling. 3. Deviation of luminance is also more groat when local lighting exist for blackboard. And, regardless of local lighting, luminance of blackboard in side of window, from direction of floor is high because of regular reflected light. Therefore a curtain or blind must be installed pertinently.

  • PDF

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

A Numerical Prediction of Contamination Behavior in a Room under the Turbulent Flow and Pressure-Based Boundary Conditions (난류유동 압력경계조건을 가진 실내공간에서의 오염물질 거동에 관한 수치적 예측)

  • 이재헌;노홍구;김광영;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1272-1281
    • /
    • 1990
  • A numerical study to predict the contamination behavior in a room being contaminated has been performed. The room with one inlet and three exits, which maintained same pressure at the ceiling, has been chosen as test model. Six sets of calculation have been performed, for one, two or three contamination sources of 1*10$^{-4}$ kg$_{c}$/s strength at two different velocities(0.2m/s, 20m/s). Numerical results show that the number the contamination concentration near the first source increased by every 20%-30% of the maximum concentration for each increase of the contamination source.e.

A Study on the Characteristics of Fire Resistance of Window Material in Compartment Fire (건물화재시 창문재료에 따른 내화특성 연구)

  • Hur, Man-Sung;Jang, Moon-Seok;Cho, Soo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • The full-scale compartment fire tests were carried out to evaluate the characteristics of fire resistance of window material under actual fire conditions. The room size used for full-scale room fire tests was 4 by 3.8 m with 2.4 m high ceiling. The windows with PVC, Aluminum and AL+Wood frame materials were established, sofa and mattress were used as fire sources. The window contained pair glasses with the air between 6 mm glasses. Temperatures at total 32 points in the room were measured to find the temperature distribution in the room fire. It is examined that thermal effects on window frame materials such as charring, distortion, melting, structural collapse, and other effects.