하악구치부에서 Bicon 임플란트에 의해 지지되는 고정성 국소의치의 광탄성 응력분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH BICON IMPLANTS ON MANDIBULAR POSTERIOR AREA)

  • 강종운;김난영;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.412-424
    • /
    • 2004
  • Statement of problem: Several prosthetic options are available for the restoration of multiple adjacent implants. A passively fitting prosthesis has been considered a prerequisite for the success and maintenance of osseointegration. Passivity is a particular concern with multiple implants because of documented inaccuracies in the casting and soldering process. One way to avoid this problem is to restore the implants individually, however, the restorations of individual adjacent impants requires careful adjustment of interproximal contacts. Purpose: The purpose of this study was to compare the stress distribution pattern and amount surrounding Bicon implants with individual crowns and splinted restorations. Material and method: A photoelastic model of a human partially edentulous left mandible with 3 Bicon implants($4{\times}11mm$) was fabricated. For non-splinted restorations, individual crowns were fabricated on 3 abutments ($4{\times}0.65mm,\;0^{\circ}$, 2.0 mm post, Bicon Inc., Boston, USA) After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal ($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m)$), and heavy($80{\mu}m$). Splinted 3-unit fixed partial dentures were fabricated and cemented to the model. Changes in stress distribution under simulated non-loaded and loaded conditions(7.5, 15, 30 lb) were analyzed with a circular polaricope. Results: 1. Stresses were distributed around the entire body of fin in Bicon implants. 2. Splinted restorations were useful for distribution of stress around implants especially with higher loads. 3. By increasing the contact tightness between the individually restored three implants, the stress increased in the coronal portion of implants. Conclusions: Ideal adjustment of the contact tightness was important to reduce the stresses around individually restored Bicon implants.

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

Anti-seismic behavior of composite precast utility tunnels based on pseudo-static tests

  • Yang, Yanmin;Tian, Xinru;Liu, Quanhai;Zhi, Jiabo;Wang, Bo
    • Earthquakes and Structures
    • /
    • 제17권2호
    • /
    • pp.233-244
    • /
    • 2019
  • In this work, we have studied the effects of different soil thicknesses, haunch heights, reinforcement forms and construction technologies on the seismic performance of a composite precast fabricated utility tunnel by pseudo-static tests. Five concrete specimens were designed and fabricated for low-cycle reciprocating load tests. The hysteretic behavior of composite precast fabricated utility tunnel under simulated seismic waves and the strain law of steel bars were analyzed. Test results showed that composite precast fabricated utility tunnel met the requirements of current codes and had good anti-seismic performance. The use of a closed integral arrangement of steel bars inside utility tunnel structure as well as diagonal reinforcement bars at its haunches improved the integrity of the whole structure and increased the bearing capacity of the structure by about 1.5%. Increasing the thickness of covering soil within a certain range was beneficial to the earthquake resistance of the structure, and the energy consumption was increased by 10%. Increasing haunch height within a certain range increased the bearing capacity of the structure by up to about 19% and energy consumption by up to 30%. The specimen with the lowest haunch height showed strong structural deformation with ductility coefficient of 4.93. It was found that the interfaces of haunches, post-casting self-compacting concrete, and prefabricated parts were the weak points of utility tunnel structures. Combining the failure phenomena of test structures with their related codes, we proposed improvement measures for construction technology, which could provide a reference for the construction and design of practical projects.

반도체 웨이퍼 다이싱용 나노 복합재료 블레이드의 제작 (Fabrication of Organic-Inorganic Nanocomposite Blade for Dicing Semiconductor Wafer)

  • 장경순;김태우;민경열;이정익;이기성
    • Composites Research
    • /
    • 제20권5호
    • /
    • pp.49-55
    • /
    • 2007
  • 반도체 쿼츠 웨이퍼 다이싱용 블레이드는 마이크로/나노 디바이스와 부품을 제조하기 위해 고정밀도의 가공성을 요구한다. 따라서 균일한 마이크로/나노 선폭의 가공을 위해서는 블레이드의 제작 단계에서 균일한 두께와 밀도를 유지하는 것이 중요하다. 기존의 실리콘웨이퍼 가공을 위해서는 금속의 블레이드가 사용되고 있지만 쿼츠 웨이퍼 가공을 위해서는 고분자 복합재가 사용된다. 이러한 복합재는 가공성, 전기전도성, 그리고 적절한 강도와 연성 및 마모저항성이 있어야 한다. 그러나 기존의 건식성형 공정으로는 균일성을 유지하기 위해 많은 공정과 비용이 소비되고 있다. 본 연구에서는 도전성 나노 세라믹스 분말, 연마재 세라믹스 분말에 열경화성 수지, 전도성 고분자를 혼합한 복합재 분말을 습식성형 공정에 의해 제조, 평가하는 연구를 수행하였다. 먼저 복합재 분말을 액상과 혼합하여 블레이드를 제작하였으며, 액상의 종류, 액상 건조공정의 영향을 고찰하였다. 평가는 마이크로미터 측정기와 현미경을 이용하여 두께를 측정하였다. 두께편차와 기공률, 밀도, 경도, 등의 특성을 비교, 평가하였다. 그 결과 습식성형에 의해 블레이드의 두께편차를 감소시킬 수 있었으며, 경도 등의 특성을 향상시킬 수 있었다.

이산화염소 자체 방출 스마트 샤쉐의 제조 및 특성 연구 (Preparation and Characterization of ClO2 Self-Releasing Smart Sachet)

  • 이준석;신호준;사데기 캄비즈;서종철
    • 한국포장학회지
    • /
    • 제29권1호
    • /
    • pp.1-7
    • /
    • 2023
  • 본 연구에서는 PEBAX/PEG-CA 복합필름을 제조하여 내부에 아염소산나트륨 분말을 포함한 스마트 샤쉐를 제작하였다. 또한, TGA, DSC, FT-IR, UV-vis를 통해 샤쉐의 화학적 구조 및 열적 특성과 더불어 샤쉐 적용성 평가를 위해 이산화염소 가스 방출량을 측정하였다. PEBAX/PEG-CA 복합필름은 친수성 및 혼화성을 바탕으로 매트릭스 내에서 강한 화학적 상호작용을 하는 것을 확인하였다. 특히, 구연산의 함량이 높아질수록 복합필름의 열 안정성이 저하되었지만, 저온 및 상온의 유통환경과 필름 제작 온도 범위(<℃)에서 열분해가 발생하지 않았으므로 샤쉐의 제작 및 적용이 가능할 것으로 사료된다. 본 연구의 핵심인 이산화염소 가스 방출량 측정에서는 스마트 샤쉐가 측정 기간인 14일 동안 내부 아염소산나트륨의 이산화염소 가스 방출을 지속적으로 활성화했으며, 산층의 구연산 함량이 높아짐에 따라 방출량이 증가하는 것을 확인하였다. 따라서, 스마트 샤쉐 내부의 아염소산나트륨 함량 및 산층의 구연산 함량 조절 또는 포장크기의 변경 등을 통해 이산화염소 방출량을 효과적으로 조절할 수 있으며, 이는 별도의 설비 및 고가의 장비 없이도 살균 효과를 연장시키는 이점이 있다. 위 실험 결과에 따라 제품 특성 및 포장 용적에 따라 스마트 샤쉐의 응용 적용이 가능할 것으로 판단된다. 하지만, 확실한 소비자 안정성 확보와 스마트 샤쉐의 적용 확장성을 확인하기 위해 항균성 및 저장성 측면에서 향후 연구가 필요하다.

레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향 (Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy)

  • 정홍택;;박진홍;신주희;이정열
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.95-101
    • /
    • 2019
  • 목적: 레진 시멘트와 코발트 크롬 합금 간의 미세인장결합강도에 다양한 프라이머들이 미치는 영향을 평가하기 위한 것이다. 재료 및 방법: 본 실험에서는 4개의 프라이머(Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer)와 2개의 레진 시멘트(Panavia F2.0, G-CEM LinkAce)를 사용하였고, 길이 6 mm, 폭 1 mm, 두께 1 mm의 150개의 코발트 크롬 빔들이 캐스팅 과정을 통해 제작되었다. 150개의 코발트 크롬 빔들을 프라이머와 레진 시멘트의 종류에 따라 프라이머 처리를 하지 않은 대조군을 포함하여 10개 그룹으로 나누었다. 금속과 레진시멘트를 산화알루미늄($125{\mu}m$ 크기)으로 샌드블라스팅 처리한 후 실리콘 틀을 이용하여 접착시켰다. 실험 전에, 입체현미경(stereomicroscope)을 이용하여 모든 금속-레진 빔들을 검사하였고, 미세인장결합강도 실험을 시행하였다. 통계적인 평가에는 one-way ANOVA와 Tukey's test를 사용하였다. 결과: 모든 그룹들의 평균 미세인장결합강도는 20 - 28 MPa이었으며, 그룹 간에 통계적으로 유의한 차이는 없었다. Panavia F2.0과 G-CEM LinkAce 그룹 모두에서 접착 파절과 응집 파절이 동시에 나타나는 혼합 파절이 가장 흔하게 일어난 파절 양태였다. 결론: 모든 실험군들의 미세인장결합강도는 상대적으로 높았지만, 본 실험에서는 프라이머의 사용이 Panavia F2.0 및 G-CEM LinkAce 레진시멘트와 코발트 크롬 합금 사이의 미세인장결합강도를 증가시키지 않았다.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

Influence of shape and finishing on the corrosion of palladium-based dental alloys

  • Milheiro, Ana;Muris, Joris;Kleverlaan, Cornelis J.;Feilzer, Albert J.
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.56-61
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS. Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were used to cast two crowns and two disks. One of each was polished while the other was not. Two as-received alloys were also studied making a total of 5 specimens per alloy type. The specimens were submersed for 7 days in a lactic acid/sodium chloride solution (ISO standard 10271) and evaluated for surface structure characterization using SEM/EDAX. The solutions were quantitatively analysed for the presence of metal ions using ICP-MS and the results were statistically analysed with one-way ANOVA and a Tukey post-hoc test. RESULTS. Palladium is released from all specimens studied (range $0.06-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$), with the Pd-Cu alloy releasing the highest amounts. For both types of alloys, ion release of both disk and crown pairs were statistically different from the as-received alloy except for the Pd-Ag polished crown (P>.05). For both alloy type, disk-shaped pairs and unpolished specimens released the highest amounts of Pd ions (range $0.34-7.08{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). Interestingly, in solutions submerged with cast alloys trace amounts of unexpected elements were measured. CONCLUSION. Shape and surface treatment influence ion release from dental alloys; polishing is a determinant factor. The release rate of cast and polished Pd alloys is between $0.06-0.69{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$, which is close to or exceeding the EU Nickel Directive 94/27/EC compensated for the molecular mass of Pd ($0.4{\mu}g{\cdot}cm^{-2}{\cdot}week^{-1}$). The composition of the alloy does not represent the element release, therefore we recommend manufacturers to report element release after ISO standard corrosion tests beside the original composition.

Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness

  • Ayyildiz, Simel;Soylu, Elif Hilal;ide, Semra;Kilic, Selim;Sipahi, Cumhur;Piskin, Bulent;Gokce, Hasan Suat
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.471-478
    • /
    • 2013
  • PURPOSE. The aim of the study was to evaluate the effect of annealing on the nanostructure and hardness of Co-Cr metal ceramic samples that were fabricated with a direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS. Five groups of Co-Cr dental alloy samples were manufactured in a rectangular form measuring $4{\times}2{\times}2$ mm. Samples fabricated by a conventional casting technique (Group I) and prefabricated milling blanks (Group II) were examined as conventional technique groups. The DMLS samples were randomly divided into three groups as not annealed (Group III), annealed in argon atmosphere (Group IV), or annealed in oxygen atmosphere (Group V). The nanostructure was examined with the small-angle X-ray scattering method. The Rockwell hardness test was used to measure the hardness changes in each group, and the means and standard deviations were statistically analyzed by one-way ANOVA for comparison of continuous variables and Tukey's HSD test was used for post hoc analysis. P values of <.05 were accepted as statistically significant. RESULTS. The general nanostructures of the samples were composed of small spherical entities stacked atop one another in dendritic form. All groups also displayed different hardness values depending on the manufacturing technique. The annealing procedure and environment directly affected both the nanostructure and hardness of the Co-Cr alloy. Group III exhibited a non-homogeneous structure and increased hardness ($48.16{\pm}3.02$ HRC) because the annealing process was incomplete and the inner stress was not relieved. Annealing in argon atmosphere of Group IV not only relieved the inner stresses but also decreased the hardness ($27.40{\pm}3.98$ HRC). The results of fitting function presented that Group IV was the most homogeneous product as the minimum bilayer thickness was measured (7.11 ${\AA}$). CONCLUSION. After the manufacturing with DMLS technique, annealing in argon atmosphere is an essential process for Co-Cr metal ceramic substructures. The dentists should be familiar with the materials that are used in clinic for prosthodontics treatments.

종이 의상에 관한 연구 - 수제지를 중심으로 - (A Study on the Paper Clothing -on the basis of handmade paper-)

  • 이주실;김정혜
    • 복식
    • /
    • 제44권
    • /
    • pp.181-199
    • /
    • 1999
  • The industry of modern clothing has deviated from the overflow of commercialism and the standardization and nowadays is going toward pursuing art, creativity, and high added value. This trend brings the return of the natural materials from the synthetic textiles and increases the value of old and handmade fabrics. Finally, the handmade-paper, which is a natural material, comes to be reconsidered as a new material for the clothing. Therefore, as the natural materials and the manufacture of handmade clothing are rising again, the qualitative improvement and globalization of clothing industry should be first realized through the developments of creative and various clothing materials and new expressing techniques. The above investigation and study have been synthesized and analyzed as follows: First, through the study on the origin of the paper clothing, its historical background and the process of its development, we've learned these two facts following : the paper clothing of the East in the past mostly had practiced meanings. On the other hand, in the West it had meanings which were raised the artist's emotions and beauty-consciousness to the artistic level by the various kinds of expressing methods. Second, handmade-paper was manufactured by the embedding method, which mixed mulberry pulp, gauze, corn, hair, sisal, silk and so on. It was found that handmade-paper had the affluent and proper texture as the clothing material and was be able to control the clarity through the variation of thickness. It was also confirmed that the creative and original texture with hand-worked molding beauty was obtained by the use of handmade-paper. Third, when the handmade-paper is used, the molding beauty of plane, relievo, and solid can be freely pursued, and various and effective molding conformation can be constructed by the effect of superposition and repetition. Also, because the maximum discretion from the various optional manufacturing methods is allowed, the molding beauty can be maximized when the clothes are manufactured with handmade-paper. Fourth, the gauze with strong drape was combined to overcome the stiffness and the tearing of the paper. As a result, the durability and the wearability of the paper were strengthened and thus the thus the applications as the clothing material were enlarged. In conclusion, in order to enhance the value, creativity, practicality, and artistic sense of the design for modern clothing, the clothes made of handmade-paper should be more studied. Moreover, for the generalization of paper clothes, the studies on the development of practical paper with paper with water resistance, post-treatment after dyeing, flexibility, and durability should be done. I really hope that this study will be the motive to provoke the possibility of handmade-paper as new clothing material in not only practical sense but also artistic sense.

  • PDF