• Title/Summary/Keyword: capillary column

Search Result 188, Processing Time 0.025 seconds

Simultaneous Analysis of Inorganic Cations by Capillary Zone Electrophoresis (Capillary Zone Electrophoresis를 이용한 양이온 동시분석에 관한 연구)

  • Park, Sung-Woo;You, Jae-Hoon;Jin, Kwang-Ho;Seo, Bae-Sug;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.341-345
    • /
    • 1999
  • The separation and determination of inorganic cations by a capillary zone electrophoresis was studied. Cations were separated by the capillary column and detected by indirect UV method. The running buffer of 0.03 M creatinine and 0.02 M-hydroxy isobutylic acid solution (pH 4.8) was used to improve the mobility of ions in the column. A potential of 18 kV was applied at anode. A complete separation of cations ranged within 15 min and detection limits were between 0.1 and 1.0 ppm. The applicability of the method for real samples was demonstrated.

  • PDF

Dual Capillary Column System for the Qualitative Gas Chromatography: 1. Comparison Between Split and Splitless Injection Modes

  • Kim, Kyoung-Rae;Kim, Jung-Han;Park, Hyoung-Kook;Oh, Chang-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.1
    • /
    • pp.87-92
    • /
    • 1991
  • A dual capillary column system is described for the simultaneous measurement of retention index (RI) and area ratio (AR) values of each peak on two capillary columns of different polarity, DB-5 & DB-1701. Both capillary columns were connected to a common splitless injector via a deactivated fused-silica capillary tubing of 1 m length and a 'Y' splitter, the dead volume effect of which was found to be negligible. RI and AR were measured with high reproducibility(${\leq}$0.05% RSD) and with high accuracy (<10% RE), respectively. When applied to the test samples of the organic acid mixture, each acid was positively identified by the combined computer RI library search-AR comparison.

Comparative Studies on Methods of Extracting Polyacetylene Compounds from White Ginseng (인삼 Polyacetylene 성분의 추출방법 비교연구)

  • 노길봉;손현주
    • Journal of Ginseng Research
    • /
    • v.13 no.2
    • /
    • pp.198-201
    • /
    • 1989
  • The amounts of panaxynol and panaxydol, which are major polyacetylone compounds In white ginseng were determined by capillary-GC (FID), and the extraction efficiencies when using varictus extraction solvents (petroleum ether, dichloromethane, ether, ethyl acetate, acetone, acetonitrilr and methanol) and various extraction methods (shaking, Soxhlet and reflux) were compared . The GC column was SPB-1 fused silica capillary (0.25 mm id x30 m, Supelco), and the column oven temperature was programmed to rise from $200^{\circ}C$ to $300^{\circ}C$ at the rate of $4^{\circ}C$ per minute. The extraction efficiencies for panaxynol and panaxydol according to extraction souvtints were the highest in methanol and decreased in the order of dichloromethane, acetone, ether, ethyl acetate, acetonitrile and petroleum ether. The extracttion efficiencies for panaxynol and panaxydol according to extraction methods were the highest for reflux and the lowest for shaking, and those with Soxhlet were almost equal to those for reflux. The analytical amounts of panaxynol and panaxydol obtained by reflux with methanol %mere 4.2 and 6.4 mg/g, respectittely in white ginseng.

  • PDF

Development of Portable Gas Chromatography / Photoionization Detector System (휴대용 기체 크로마토그래피 / 광이온화 검출기 시스템의 개발)

  • Kim, Man Gu;Sim, Ji Hui;Lee, Dong Su;Lee, Yong Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.151-159
    • /
    • 1994
  • The portable gas chromatography system was developed which was consisted of ambient vapor sampler(AVS), short capillary column(3 m long, 0.32 mm i.d. GC(SCCGC), photoionization detector (PID) and vacuum pump which was operated at subambient pressure. The seletion of capillary column was based on the theoretical calculation from Golay equation. The pressure ratio of column inlet and outlet appropriated between 1.03 and 1.2 in the system. The available column flow were 0.87∼4.63 ml/min at the pressure ratios. The AVS consisted of three concentric tubes and enables rapid, repetitive introduction of vapor samples directly into capillary column and showed good reproducibility. The subambient column outlet pressure with PID resulted in a significant increase in the optimum column flow, permitting rapid analysis. The baseline separation of m-xylene and o-xylene was able to within 40 second with the system. Parameters affecting the column resolving power were sampling duration, column length and diameter, and the pressure ratio. Effects of these parameters were investigated using bezene derivative compounds.

  • PDF

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF

Development of Conductivity Cell and Suppressor for Capillary Column Ion Chromatography (모세관 컬럼 이온 크로마토그래피를 위한 Conductivity Cell과 Suppressor의 개발)

  • Pyo, Dongjin;Kim, Hohyun
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.89-93
    • /
    • 1999
  • In this study, conductivity cell and suppressor for micro-column ion chromatography were developed to analyze ions in small columns of samples. With a capillary column, the flow rate of the mobile phase is so small (usually $5{\sim}20{\mu}L/min$) that the usual conductivity cell can not be used. Therefore, we developed a new type of conductivity cell and suppressor which have small inner volumes. The conductivity cell was made with two Pt hypodermic needles (i.d. 0.010 mm) which are slightly separated (about $2{\mu}m$), and the suppressor was made of Nafion tubings. When several anions(fluoride, nitrite, nitrate, chlorate) were analyzed using developed conductivity cell and suppressor, a good chromatogram was obtained.

  • PDF

Capillary Characteristics of Water and Cations in Multi-layered Reclaimed Soil with Macroporous Subsurface Layer Utilizing Coal Bottom Ash

  • Ryu, Jin-Hee;Chung, Doug-Young;Ha, Sang-Keon;Lee, Sang-Bok;Kim, Si-Ju;Kim, Min-Tae;Park, Ki-Do;Kang, Hang-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.406-411
    • /
    • 2014
  • Serious problems in reclaimed land agriculture are high soil salinity and poor vertical drainage, so desalinization in these soils is very difficult. Also, although desalinization is accomplished in reclaimed top soils, before long, soils are resalinized according to capillary rise of salts from the subsurface soils. To resolve these problems, multi-layered soil columns with subsurface layer of macroporous medium utilizing coal bottom ash (CBA) were constructed and the effects of blocked resalinization of these soils were investigated. In this experiment soil samples were collected from Munpo series (coarse-loamy, nonacid, mixed, mesic, typic Fluvaquents). The soil texture was silt loam and the EC was $33.9dS\;m^{-1}$. As for groundwater seawater was used and groundwater level of 1 cm from the bottom was maintained. The overall rate of capillary rise was $2.38cm\;hr^{-1}$ in soil 60 cm column, $0.25cm\;hr^{-1}$ in topsoil (30 cm) + CBA (5 cm) + subsurface soil (10 cm) column and $0.08cm\;hr^{-1}$ in topsoil (30 cm) + CBA (10 cm) + subsurface soil (10 cm) column. In multi-layered soil columns with CBA 20, 30 cm layer, wetting front due to capillary rise could not be seen in top soil layer. After 70 days capillary rise experiment water soluble Na+ accumulated in top soil of soil columns with CBA 20, 30 cm was diminished by 92.8, 96.5% respectively in comparison with Na+ accumulated in top soil of soil 60 cm column because CBA layer cut off capillary rise of salts from the subsurface soil. From these results we could conclude that the macroporous layer utilizing CBA placed at subsurface layer cut off capillary rise of solutes from subsurface soil, resulting in lowered level of salinity in top soil and this method can be more effective in newly reclaimed saline soil.

Influence of Heating Conditions on the Formation of Acrylamide and Other Products in Asparagine-Glucose Model Reaction System (Model reaction system에서 가열조건이 acrylamide 및 기타 화합물들의 생성에 미치는 영향)

  • Lee Young-Guen
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.323-327
    • /
    • 2006
  • The Formation of acrylamide was studied in Maillard model reaction systems based on asparagine-glucose. The mixture of asparagine and glucose in equal molar ratio, and then heated at 125, 150, 175 and $200^{\circ}C$ for 10, 20 and 30 minute, respectively. The reaction products were extracted with ethyl acetate and methanol, and then isolated and detected on FFAP capillary column and HP-5MS 5% phenyl methyl siloxane column by using GC/MS. Acrylamide was detected only from methanol extracts and on FFAP capillary column, at retention time 23.53 min., and the detection limit was 4.6 ng. Acrylamide content mainly increased with increasing temperature and processing time till $175^{\circ}C$, therefore, maximal acrylamide formation occurred at $175^{\circ}C$ for 10 minute ($116{\mu}g/g$), while, above $175^{\circ}C$, higher temperatures or prolonged processing times caused a decrease of acrylamide levels, finally disappeared at $200^{\circ}C$ for 30 minute. Three major compounds were identified as 1,3-dihydroxypropanone, 2,3-dihydro-3,5-dihydroxy-6-methyl-4H-pyrane-4-one and 5-hydroxymethylfurfural, and three minor compounds also as 5-methylfurfural, 2-acetylpyrrole and N,N-dimethylcyclohexamine, from ethyl acetate or methanol extracts on FFAP or HP-5MS capillary column.

Study on the Development of Analytical Method (Multi-Pesticide Residue Method) for Organophosphate Pesticides (유기인제 농약 분석 방법 (Multi-Pesticide Residue Method) 개발에 관한 연구)

  • 이봉헌;김우성
    • Journal of Environmental Science International
    • /
    • v.6 no.2
    • /
    • pp.183-187
    • /
    • 1997
  • Organophosphate pesticides were extracted with 70% acetone and then transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil. The florial extract was analyzed by gas chromatography with nitrogen-phosphorus detector(GC/NPD). Recoveries of the 18 organophosphate pesticides were ranged from 88.7% to 100. 0% for the narrow-bore capillary GC(Ultra-21. The minimum detectable level of this analytical method was 0.019 - 0.035 mg/kg. Sample throughput(extraction, open-column chro- matography, and GC analysts) was decreased considerably (8h per sample).

  • PDF