• Title/Summary/Keyword: cancellous bone density

Search Result 41, Processing Time 0.028 seconds

EXPERIMENTAL STUDY ON THE EFFECT OF CALCITONIN IN THE OSTEOPOROSIS INDUCED BY THE IMMOBILIZATION AND LONG-TERM GLUCOCORTICOID (Glucocorticoid의 장기간 투여 및 운동 억제에 의한 골손실시 calcitonin의 예방효과에 관한 실험적 연구)

  • Park Dong Jin;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.69-87
    • /
    • 1989
  • It is well known that the glucocorticoid induces osteoporosis by suppression of the osteoblast, but its effect on the osteoclast hRS some controversy whether it activates or suppresses the osteoclast. If the calcitonin, which is known to suppress the osteoclast, prevents the osteoporosis by glucocorticoid, then the suppression of the osteoclast by the glucocorticoid is not so significant. And if the calcitonin increases the osteoblastic activity, Tc-99m MDP uptake will be increased in spite of the glucocorticoid effect on the osteoblast. The immobilization operation was performed to the right leg of male Wistar rats weighing about 200gm. each. For 16 weeks after operation, rats were injected glucocorticoid alone or glucocorticoid anci calcitonin. The bone density was measured by means of photodensitometry under reference aluminum step wedge and Tc-99m MDP uptake was available to the index of the osteoblastic activity. 1. The bone density of femora! head was markedly reduced than that of femoral shaft following ration of cancellous and cortical components in both site. 2. Glucocorticoid caused decrease in bone density of spine and femur, md there is significantly increase of it when medication of glucocorticoid and calcitonin injection simultaneously than that of glucocorticoid. 3. Tc-99m MDP uptake was revealed significant reduction in medication of glucocorticoid but increase in gi;.:cocorticoid and calcitonin injection simultaneously in later experimental period. 4. There wail, a slight reduction in plasma osteocalcin in medication of glucocorticoid through experimental periods and an increase in its value in case of giving glucocorticoid and calcitonin simultaneously in later experimental period. From these results, we suggest that osteoporosis by immobilization is more pronounced by glucocorticoid hormone and osteoporosis induced by immobilization and glucocorticoid use is prevented by calcitonin administration with increasing osteoblastic activity.

  • PDF

Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test

  • Bayarchimeg, Dorjpalam;Namgoong, Hee;Kim, Byung Kook;Kim, Myung Duk;Kim, Sungtae;Kim, Tae-Il;Seol, Yang Jo;Lee, Yong Moo;Ku, Young;Rhyu, In-Chul;Lee, Eun Hee;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.1
    • /
    • pp.30-36
    • /
    • 2013
  • Purpose: Implant stability at the time of surgery is crucial for the long-term success of dental implants. Primary stability is considered of paramount importance to achieve osseointegration. The purpose of the present study was to investigate the correlation between the insertion torque and primary stability of dental implants using artificial bone blocks with different bone densities and compositions to mimic different circumstances that are encountered in routine daily clinical settings. Methods: In order to validate the objectives, various sized holes were made in bone blocks with different bone densities (#10, #20, #30, #40, and #50) using a surgical drill and insertion torque together with implant stability quotient (ISQ) values that were measured using the Osstell Mentor. The experimental groups under evaluation were subdivided into 5 subgroups according to the circumstances. Results: In group 1, the mean insertion torque and ISQ values increased as the density of the bone blocks increased. For group 2, the mean insertion torque values decreased as the final drill size expanded, but this was not the case for the ISQ values. The mean insertion torque values in group 3 increased with the thickness of the cortical bone, and the same was true for the ISQ values. For group 4, the mean insertion torque values increased as the cancellous bone density increased, but the correlation with the ISQ values was weak. Finally, in group 5, the mean insertion torque decreased as the final drill size increased, but the correlation with the ISQ value was weak. Conclusions: Within the limitations of the study, it was concluded that primary stability does not simply depend on the insertion torque, but also on the bone quality.

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Effect of Bone Marrow Aspirate with Autogenous Bone graft for Alveolar Cleft in a new Rabbit Model (가토의 치조열 모델에서 골수 흡인물이 자가뼈 이식술에 미치는 효과)

  • Bae, Sung Gun;Chung, Ho Yun;Lee, Sang Yun;Cho, Byoung Chae;Yang, Jung Dug;Park, Mee Young
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.531-537
    • /
    • 2009
  • Purpose: Alveolar bone grafting has become an essential process in the treatmemt of alveolar cleft patient for stabilization of the maxillary arch, elimination of oronasal fistula, the reconstruction of the soft tissue nasal base support, and creation of bony support for tooth eruption for implant. The use of Autologous iliac cancellous bone is preferable because of the adequate quantity and high osteoinductive potential. However, even with iliac bone, insufficient osteoregeneration and absorption occur due to several factors such as the patient's age, cleft width, functional stress, and others. In order to increase osteoregeneration where the iliac bone is placed, the present study is associated with bone marrow aspirate (BMA). The experimental study evaluated the efficacy of osteoregeneration in normal cleft rabbits when alveolar bone grafting was performed with autologous iliac corticocancellous bone. Methods: Twenty - four New Zealand White rabbits were divided randomly into 2 groups (BMA, control). All animals underwent harvesting of corticocancellous bone graft from the right posterior iliac crest via standard surgical technique. $1m{\ell}$ of BMA were obtained by scraping the needle and aspirate with $10m{\ell}$ syringe from the contralateral iliac bone wall. The muco - periosteal flap on the palate was elevated. A mixture of Equal bone's volumes with BMA and saline as its control was inserted into the cleft. Animals were sacrificed at 2, 4, and 8 weeks and maxilla was harvested for dental peri - apical X-ray, bone matrix density (BMD),and histologic analysis. Result: BMD of regenerated bone to the cleft in the rabbits was higher than that of the control rabbits. X-ray, histologic analysis showed that increased osteoregeneration and low absorption rate were observed in the BMA group. Conclusion: Our experimental study showed BMA enhanced the osteoregeneration and survival rate of alveolar bone grafting. BMA is easy to extract & cost - time effective. So it can be an effective enhancers for bone grafting mixtures.

EFFECT OF IMPLANT DESIGNS ON INSERTION TORQUE AND IMPLANT STABILITY QUOTIENT (ISQ) VALUE

  • Piao Chun-Mei;Heo Seong-Joo;Koak Jai-Young;Kim Seong-Kyun;Han Chong-Hyun;Fang Xian-Hao
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.325-332
    • /
    • 2006
  • Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant stability and osseiointegratation are considered highly desirable. Purpose. The purpose of this study was to evaluate the ISQ value and the insertion torque of the 3 different implant system, then to evaluate whether there was a correlation between ISQ value and insertion torque; and to determine whether implant design has an influence on either insertion torque or ISQ value. Material and method. The experiment was composed of 3 groups: depending on the implant fixture design. Group1 was Branemark type parallel implant in $3.75{\times}7mm$. Group2 was Oneplant type straight implant in $4.3{\times}8.5mm$. Group3 was Oneplant type tapered implant in $4.3{\times}8.5mm$. Depending on the density of the bone, 2 types of bone were used in this experiment. Type I bone represented for cortical bone, type II bone represented for cancellous bone. With the insertion of the implant in type I and type II bone, the insertion torque was measured, then the ISQ value was evaluated, and then the correlation between insertion torque and ISQ value was analyzed Result and conclusion. Within the limitations of this study, the following conclusions were drawn. 1. Within the 3 different implants, the insertion torque value and ISQ value were higher in type I bone, when compared with type II bone.(p<0.05) 2. In type I and type II bone, Oneplant type tapered implant has the highest value in insertion torque.(p<0.05) 3. In type I and type II bone, there was no difference in ISQ values among the 3 types of implant. (p>0.05) 4. Significant linear correlation was found in $Br{\aa}nemark$ type parallel implant: $3.75{\times}7mm$ in type II bone.

Analysis about Associated Factors of Nonunion Following Tibiotalar Arthrodesis (경거골유합술 후 발생하는 불유합과 관련된 인자에 대한 분석)

  • Lee, Jun Young;Kim, Bo Sun;Lee, Jung Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.3
    • /
    • pp.98-103
    • /
    • 2017
  • Purpose: The aim of this study was to analyze the factors related to nonunion in tibiotalar arthrodesis. Materials and Methods: Eighty cases of ankle arthritis treated with tibiotalar arthrodesis in our hospital from November 2008 to November 2015 with more than one year follow up were analyzed. Simple anteroposterior and lateral radiographs after 6 and 12 months of surgery were analyzed. Union was defined as more than 50% connection of the trabecular bone at the ankle joint surface in the anteroposterior and lateral radiographs. The nonunion group was defined as no signs of union with persistent pain 9 months after surgery. The surgical approach, type of used screw, preoperative and postoperative ankle alignment, body mass index (BMI), bone mineral density, and patients' prior history were compared between the two groups. Results: There were 69 union cases and 11 nonunion cases. In the patient factors, the gender and BMI was related to nonunion (p<0.05). The mean preoperative and postoperative ankle alignment in the nonunion group was $9.93^{\circ}{\pm}6.92^{\circ}$ and $5.43^{\circ}{\pm}3.35^{\circ}$ respectively, and $9.80^{\circ}{\pm}7.55^{\circ}$ and $5.63^{\circ}{\pm}3.45^{\circ}$ in the union group, respectively; the difference was not statistically significant (p>0.05). In the technical factors, the transfibular approach showed a better relationship but the association was not significant (p<0.05). In 40 cases of the transfibular approach, 12 cases used cancellous screws, and 4 cases showed nonunion due to screw breakage. Conclusion: Technical factors, such as the surgical approach and the type of screw used can be a risk factor in nonunion. In addition, patients' factors, such as gender and BMI, must be considered to reduce the nonunion rate.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

The effect of steroid for fibrous dysplasia of the humerus combined with multiple cystic lesion (낭종성 병변을 동반한 상완골의 섬유성 골이형성증에서 steroid의 효과 - 증례 보고 -)

  • Hahn, Soo-Bong;Shin, Kyoo-Ho;Kim, Bo-Hyun;Won, Jung-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • Fibrous dysplasia is a benign pathologic condition in which the normal cancellous bone is replaced by the fibro-osseous tissue. It is found mostly in the femur, tibia, skull, rib, and humerus. Clinically it may develops pain, progressive deformity, and pathologic fracture. Curettage with bone graft has been the most popular treatment method thesedays. A 17-year-old female who had fibrous dysplasia of the humerus combined with multiple cystic lesion was treated by intralesional steroid injection into the lesion total 2 times. The follow-up plain X-ray which was taken 11 months after steroid injection reveals decrease in size and increase in bone density and cortex thickness. The follow-up MRI reveals significant decrease in size and signal intensity. The signal intensity was decreased to that of normal bone marrow in T2 weighted image. She complains no pain and lives symptom free in last follow-up at 2 years and 8 months after steroid injection.

  • PDF

Intraosseous anesthesia in symptomatic irreversible pulpitis: Impact of bone thickness on perception and duration of pain

  • Nilius, Manfred;Mueller, Charlotte;Nilius, Minou Helene;Haim, Dominik;Leonhardt, Henry;Lauer, Guenter
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.6
    • /
    • pp.367-375
    • /
    • 2020
  • Background: Intraosseous anesthesia (IO) allows the anesthetic solution to be injected directly into the cancellous bone. The anesthetic solution immediately reaches the periapical region, and thus the axonal area of the nerve, where it can temporarily disable the sodium pump. The effect is felt almost without any time delay, and only a small amount of anesthetic solution is required. Methods: This study aims to investigate the efficacy of IO using the AnestoⓇ device after infiltration anesthesia (IA) and/or inferior alveolar nerve block anesthesia (IANB) failed to work in symptomatic irreversible pulpitis (hot tooth). The 33 patients included in the study were treated additionally with 1.7 ml articaine hydrochloride with 1:100,000 epinephrine hydrochloride (UltracainⓇ D-S, Sanofi-Aventis, Frankfurt, Germany) IO. Results: The electrical pulp test showed that 95.76% of the volunteers reacted positively to the combination of IANB or IA with the IO. In women, the additive IO was effective at 97.22%. In men, the IO led to pain elimination in 94.00% of cases. The duration of the IO was less than a quarter of an hour (13.03 min). The IO worked longer in women than in men (13.61 min vs. 12.33 min). Overall, more than every third tooth that needed trepanation was located in the posterior area of the mandible (36.4%). Treatment of hot teeth in this area was associated with an increased pulse rate and increased residual pain. There was a moderate correlation (Spearman-Rho [IRI] = 0.280) between the Visual Analog Scale (VAS) score and bone density, and a significant correlation (IRI = 0.612) between subjective residual pain and bone width. The IO resulted in a moderate, transient increase in the pulse rate by approximately 20 bpm. This is similar to the temporary increase in heart rate after conventional anesthesia techniques in non-preloaded patients and can be considered clinically irrelevant. Conclusion: IO with the AnestoⓇ device as an extension and deepening of local pain elimination is recommended for the treatment of hot teeth.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.