References
- Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Impl Res 1997;8:48-57 https://doi.org/10.1111/j.1600-0501.1997.tb00007.x
- lazzara RJ, Porter SS, Testori T, Galante J, Zetterquist LA. A prospective multicenter study evaluating loading of Osseotite implants two months after placement. J Esthet Dent 1998;10:180-9
- Szmukler-Moncler S, Salama S, Reingewirta Y, DubruiIIe JH. Timing of loading and effect of micro-motion on bone-iamplant interface. J Biomed mater Res (Applied Biomaterials) 1998;43:192-203 https://doi.org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K
- Szmukler-MoncIer S, PiatteIIi A, Favero JA, Dubruills ]H. Considerations preliminary to the application of early and immediate loading protocols in implant dentistry. CIin Oral Implant Res 2000 Feb;11(1):II:12-25
- Jaffin RA, Kumar A, Berman CL. Immediate loading of implants in partially and fully edentulous jaws: a series of 27 case reports. J Periodontol 2000;71:833-38 https://doi.org/10.1902/jop.2000.71.5.833
- Glauser R, Ree A. Gottlow J, Hammerle CH, Scharer P. Immediate occlusal loading of Branemark implants applied in various jawbone regions: a prospective, '1-year clinical study. CIin Implant Dent Relat Res 2001;3:204-13 https://doi.org/10.1111/j.1708-8208.2001.tb00142.x
- Roccuzzo M, Bunino M, Prioglio F, Bianchi SD. Early loading of sandblasted and acid etched (SLA) implants: a prospective split-mouth comparative study. Clin Oral Impl Res 2001;12:572-8 https://doi.org/10.1034/j.1600-0501.2001.120604.x
- Cochran DL, Buser D, Brugenakte C, Wiengart D, Taylor T, Bernard JP, Simpson JP, Peters F. The use of reduced healing times on ITI implants with a sandblasted and etched (SLA) surface: early results from clinical trails on ITI SLA implants. Clin Oral Impl Res 2002;13:144-53 https://doi.org/10.1034/j.1600-0501.2002.130204.x
- Testori T, Del Fabbro M, Feldman 5, Vincenzi G, O' sullivan D, Rossi RJ, Anitua E, Bianchi F, Francetti L, Weinstein RL. A multicenter prospective evaluation of a 2-months loaded Osseotite implants placed in the posterior jaws: 3-year followup results. Clin Oral Impl Res 2002;13:154-61 https://doi.org/10.1034/j.1600-0501.2002.130205.x
- Esposito M, Worthington HV, Coulthard P. Interventions for replacing missing teeth: different times for loading implants. Cochrance Database Syste Rev 2003;1:CD003878
- Adell R, Lekholm U, Rockler B, Branernark, A 15-year study of osseointegtated implants in the treatment of the edentulous saw. Int J Oral Surg 1981;10:387-416 https://doi.org/10.1016/S0300-9785(81)80077-4
- Albrektsson T, Branemark P, Hansson HA, Lindstrom J. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone to implant anchorage in man. Acta Orthop Scand 1981;52:155-70 https://doi.org/10.3109/17453678108991776
- Meredith N. Assessment of implant stability as a prognostic determinanat. Int J Prosthodont 1998;11:491-501
- Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Surg 1999a;28:266-72 https://doi.org/10.1016/S0901-5027(99)80156-8
- Ostman P O, Hellman M, Wendelhag I, Sennerby L. Resonance Frequency Analysis Measurements of Implants at Placement Surgery. Int J Prosthodont 2006;19:77-83
- Gapski R, Wang H L, Mascarenhas P, Lang N P. Critical review of immediate implant loading. Clin Oral Impl Res 2003;14:515-27 https://doi.org/10.1034/j.1600-0501.2003.00950.x
- Meredith N. A review of nondestructive test methods and their application to measure the stability and osseiontegration of bone anchored end osseous implants. Crit Rev Biomed Eng 1998;26:275-91 https://doi.org/10.1615/CritRevBiomedEng.v26.i4.20
- Meredith N, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Impl Res 1997a;8:226-333 https://doi.org/10.1034/j.1600-0501.1997.080309.x
- Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Imp Res 1997b;8:234-43 https://doi.org/10.1034/j.1600-0501.1997.080310.x
- Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 1996;7:261-7 https://doi.org/10.1034/j.1600-0501.1996.070308.x
- Cunha H A, Francischone E, Filho HN, Candido R, Oliverira G. A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and tiunite single-tooth implants under immediate loading. Int Oral Maxillofac Implants 2004;19:578-85
- Johansson P, Strid KG. Assessment of bone quality from placement resistance during implant surgery. Int Oral Maxillofac Implants 1994;9:279-88
- O' sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implant a human cadaver study. Clin Implant Dent Relat Res 200;2(2):85-92 https://doi.org/10.1111/j.1708-8208.2000.tb00110.x
- O' sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and second stability of osseointegrated titanium implants. Clin Oral Impl Res 2004;15:474-80 https://doi.org/10.1111/j.1600-0501.2004.01041.x
- Sennerby L, Thomsen P, Ericsson L. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int Oral Maxillofac Implants 1992;6:62-71