• Title/Summary/Keyword: call load

Search Result 112, Processing Time 0.027 seconds

A study on the operating method for Photovoltaic system through the SOC measurement of batteies (Battery SOC(State of Charge)측정을 통한 태양광발전 시스템 운영 방안 연구)

  • Song, Jung-Yong;Seo, Yu-Jin;Kwon, Oh-Sang;Jeoung, Kwan-Chul;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper, the new improved method for photovoltaic system was studied available for a lighting load by measuring the state of charge of lead-acid batteries. Photovoltaic systems has been evaluated as one of the most new and renewable energy and especially, the Stand-Alone Photovoltaic system has been used to a street light, a road sign light, an air caution light, an emergency call. Many Stand-Alone PV system are installed by a group. Although the pre-installation cost of PV system is high and it has not been operated due to the absence of optimal management standards. In this paper, it is proposed a new operating method by the measurement of lead-acid battery's SOC with a Ah balancing.

Development of Debugging Tool for LEON3-based Embedded Systems (LEON3 기반 임베디드 시스템을 위한 디버깅 도구 개발)

  • Ryu, Sang-Moon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.4
    • /
    • pp.474-479
    • /
    • 2014
  • LEON3 is a 32-bit synthesizable processor based on the SPARC V8. It can be connected to AMBA 2.0 bus and has a 7- stage pipeline, IEEE-754 FPU and 256[KB] cache. It can be easily implemented using FPGA and used for a SoC design. DSU which comes with LEON3 can be used to control and monitor the operation of LEON3. And DSU makes it easy to set a debugging environment for the development of both hardware and software for an embedded systems based on LEON3. This paper presents the summary of the debugging tool for LEON3 based embedded systems. The debugging tool can initialize the target hardware, find out how the target hardware is configured, load application code to a specified memory space and run that application code. To provide users a debugging environment, it can set breakpoints and control the operation of LEON3 correspondingly. And function call trace is one of key functions of the debugging tool.

Robustness Design For Tall Timber Buildings

  • Voulpiotis, Konstantinos;Frangi, Andrea
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.3
    • /
    • pp.245-253
    • /
    • 2020
  • With the ever-increasing height of timber buildings, the complexity of timber as a structural material gives rise to behaviors not previously studied by engineers. An urgent call is needed regarding their performance in damage scenarios: activating alternative load paths in tall timber buildings is not the same as in tall buildings made with steel and concrete. In this paper we propose a robustness framework covering all building materials, whose application in timber may lead to new conceptual designs for the next generation of tall timber buildings. Qualitatively, the importance of building scale and the distinction between localized and systematic exposures are discussed, and how existing supertall structures can be an example for future generations of tall timber buildings. Quantitatively, the robustness index is introduced alongside a method to calculate the performance of a given building regarding robustness, in order to find the most cost-effective structural solutions for improved robustness. A three-level application recommendation is made, depending on the importance of the building in question. Primarily, the paper highlights the importance of conceptual design to achieve structural robustness and encourages the practicing engineering community to use the proposed framework to quantitatively come up with the new generation of tall timber buildings.

Method for Supporting Multiple Service in a Mobile Terminal (이동 단말기에서 다중 서비스 지원 방안)

  • Lee, Jong-Chan;Park, Sang-Joon;Lee, Jin-Kwan
    • Convergence Security Journal
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2008
  • Our paper deals with a method for supporting multiple call/sessions in a mobile terminal. The different identifier for each protocol layer is assigned to each session when a mobile terminal sets SDP for multimedia services. In particular, QoS based tasks are used for managing the traffics in radio interface. Also, queuing, admission control, load control, resource allocation and scheduling are done based on the priority of sessions. The various multimedia services which is different in the requirement of resource allocation are able to be serviced simultaneously because a mobile terminal can provide the various services based on this scheme.

  • PDF

An Acoustic Echo Canceller By Using the Reduced Lattice Filter Structure (축소격자필터 구조를 사용한 음향반향제거기)

  • 유재하;조성호;윤대희;차일환
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.11
    • /
    • pp.1473-1480
    • /
    • 1995
  • When the LMS algorithm is employed in the transversal filter structure, the computational complexity can be kept reasonably low. However, if the impulse response to be estimated is very long or signals involved are highly correlated like a speech the convergence speed becomes slow. The lattice filter is an excellent alternative to improve convergence speed since the lattice structure inherently has the orthogonal property among the backward prediction errors, but at the expense of the excessive computational load. If the input signal to be used can be sufficiently well modeled as a .RHO.-th order autoregressive(AR) process, the reflection coefficients after the .RHO.- th stage will be close to zero. Then, instead of employing the full lattice structure, the joint lattice filter structure can be implemented in conjunction with the transversal filter structure after the .RHO.-th stage. We propose, in this paper, this new lattice/transversal joint structure, and we will call it the reduced lattice filter. Using the reduced lattice filter, we are now able to achieve the performance as good as that of the lattice filter, while maintaining the complexity as low as that of the transversal filter. The proposed filter is particularly useful for an acoustic echo canceller due to the highly correlatedness nature of speeches and the long and frequently changing echo paths.

  • PDF

A Novel Cross-Layer Dynamic Integrated Priority-Computing Scheme for 3G+ Systems

  • Wang, Weidong;Wang, Zongwen;Zhao, Xinlei;Zhang, Yinghai;Zhou, Yao
    • Journal of Communications and Networks
    • /
    • v.14 no.1
    • /
    • pp.15-20
    • /
    • 2012
  • As Internet protocol and wireless communications have developed, the number of different types of mobile services has increased gradually. Existing priority-computing schemes cannot satisfy the dynamic requirements of supporting multiple services in future wireless communication systems, because the currently used factors, mainly user priority, are relatively simple and lack relevancy. To solve this problem and provide the desired complexity, dynamic behavior, and fairness features of 3G and beyond 3G mobile communication systems, this paper proposes a novel cross-layer dynamic integrated priority-computing scheme that computes the priority based on a variety of factors, including quality of service requirements, subscriber call types, waiting time, movement mode, and traffic load from the corresponding layers. It is observed from simulation results that the proposed dynamic integrated priority scheme provides enhanced performance.

A Numerical Analysis of Heat Transfer in Bright Annealing Furnace of Stainless Steel Strip (Strainless steel strip 광휘어닐링로 내의 열전달 해석)

  • Ryou, H.S.;Jeong, Y.T.;Jang, B.L.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.4
    • /
    • pp.228-233
    • /
    • 2009
  • In order to predict the temperature distribution of stainless steel strip in Bright Annealing (BA) furnace, we performed the analysis of heat transfer and fluid flow using STAR-CCM+. The analysis model included unsteady fluid flow, heat transfer with radiation and moving grid. Two kinds of radiative properties, emissivity and reflectivity, were applied to the stainless steel strip, one is constant and the other is variable with time. As we call, the BA furnaces of stainless steel strip have two different types, muffle and no-muffle. The using of muffle type has been faced with some problems such as rising in material price and shortening of life cycle, etc. So the development of no-muffle type BA furnace is very important in order to save energy cost, lower environmental load and increase the productivity. The designed (or expected) temperature of stainless steel strip coming out of BA furnace was about $1065^{\circ}C$ while the environment temperature maintains around $1100^{\circ}C$. The result of our calculation was very close (or similar) to design temperature, and the application of radiative properties variable with time produced more accurate result than applying constant ones.

Performance Analysis of Handoff Channel Assignment Scheme in CDMA Cellular System (CDMA 셀룰러시스템에서의 핸드오프 채널할당기법 성능분석)

  • Lee, Dong-Myung;Lee, Chul-Hee
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.6
    • /
    • pp.17-29
    • /
    • 1999
  • In this paper, the prioritized queueing handoff scheme in CDMA (Code Division Multiple Access) cellular system is proposed. Also, the analytical survey for the proposed scheme is carried out, and the performance of this scheme is compared with that of non prioritized scheme and FIFO (First In First Out) queue scheme by computer simulation. The handoff region is defined as the time between the handoff treshold and the receiver threshold, and it is used for the maximum queue waiting time in the proposed scheme. The handoff and the receiver thresholds are defined as rewpectively: 1) the time that the Pilot Strength Measurement Message in the neighbor in the neighbor cell is received to the BS (Base Station) under the T_ADD threshold; and 2) the time that the T_DROP timer is expired and the Pilot Strength Measurement Message in the current cell is received to the BS under the T_DROP threshold. The performance metrics for analyzing the proposed scheme are : 1) probability of forced termination; 2) probability of call blocking; 3) ratio of carried traffic to total offered load; 4) average queue size; 5) average handoff delay time in queue. The simulation results show that the proposed scheme maintains high performance for handoff requests at a small penalty in total system capacity.

  • PDF

Design and Evaluation of a NIC-Driven Host-Independent Network System (네트워크 인터페이스 카드에 기반한 호스트 독립적인 네트워크 시스템의 설계 및 성능평가)

  • Yim Keun Soo;Cha Hojung;Koh Kern
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.11
    • /
    • pp.626-634
    • /
    • 2004
  • In a client-server model, network server systems suffer from both heavy communication and computational loads. While communication channels become increasingly speedy, the existing protocol stack architectures still include mainly three performance bottlenecks of protocol stack processing, system call, and network interrupt overheads. To address these obstacles, in this paper we present a host-independent network system where a network interface card (NIC) is utilized in an efficient manner. First, by offloading network-related portion to the NIC, the host can fully utilize its processing power for other useful purposes. Second, it eliminates the system call overhead, such as context-switching and memory copy operations, since the host communicates with the NIC through its user-level libraries. Third, it a] so reduces the network interrupt operation count as the host handles the interrupt in a segment instead of a packet. The experimental results show that the proposed network system reduces the host CPU overhead for communication system by 68-71%. It also shows that the proposed system improves the communication speed by 11-83% under heavy computational and communication load conditions.

An Evaluation of Operator Performance Related to the Switch Types in Man Control Rooms of the Nuclear Power Plants (주관적 작업부하 평가기법을 이용한 원자력 발전소 주제어반 제어 스위치 사용 인적 수행도 평가)

  • Byun, Seung-Nam
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-65
    • /
    • 2000
  • The objective of this study is to evaluate the operator performance relating to hand switches with two or three buttons in the main control rooms of nuclear power plants. Based on the comparative analysis of the nuclear power plants, two different subjective workload-rating scales were used to evaluate the performance of 48 operators: the Overall Workload(OW) and National Aeronautics and Space Administration Task Load Index (NASA TLX). The survey questions consisting of the eight-items were asked to evaluate the operating experiences for the two different switch types. The OW scales ratings were applied to measure the workload of the switch-related tasks. The ratings revealed that signal detection tasks caused less workload in the three-buttoned-switch operators than the other switch group. However, in the switch operation tasks, the switch types did not show statistically significant effects on workload level. The NASA TLX scale ratings were performed based on detailed task scenarios that assumed the accident of small break loss of coolant, what we call, the small LOCH. The NASA TLX was administered to three different task groups: the reactor, the turbine, and the electric operator groups. Based on the NASA TLX, the two-buttoned switch groups showed higher workload than those with the three-buttoned switches. However, a statistically significant difference was found only in the reactor operator groups. When the current switch type was assumed to be changed for the other type, all of the three-buttoned switch groups were predicted to have higher workload than the other switch groups, respectively. The implications of these findings were discussed.

  • PDF