• Title/Summary/Keyword: cadence

Search Result 440, Processing Time 0.047 seconds

Flyback AC-DC Converter with Low THD Based on Primary-Side Control

  • Chang, Changyuan;He, Luyang;Cao, Zixuan;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1642-1649
    • /
    • 2018
  • A single-stage flyback LED AC-DC converter based on primary-side control under constant current mode is proposed in this study. The proposed converter features low total harmonic distortion (THD) and high power factor (PF). It also consists of a zero-crossing distortion compensation circuit and a variable duty ratio control compensation circuit to deal with the line current distortions caused by fixed duty ratio control. The system model and layout are built in Simplis and Cadence, respectively. The feasibility and performance of the proposed circuit is verified by designing and fabricating an IC controller in the HHNEC $0.35{\mu}m$ 5 V/40 V HVCMOS process. Experimental results show that the PF can reach a level in the range of 0.985-0.9965. Moreover, the average THD of the entire system is approximately 10%, with the minimum being 6.305%, as the input line voltage changes from 85 VAC to 265 VAC.

Effect of Kinesiology Taping for Ankle Instability in Stroke Patients

  • Oh, Donghwan;Park, Jaeyoung;Kim, Jinuk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.1
    • /
    • pp.1950-1953
    • /
    • 2020
  • Background: Ankle instability usually occurs after stroke, and contributes to unsafe walking and associated risk of falling in the affected patients. Objective: To investigate the effects of kinesiology taping (KT) on gait and balance ability (center of pressure, CoP) in patients with ankle instability after stroke. Design: One group, pre-post design. Methods: A total of 11 patients with ankle instability after stroke were enrolled. In all subjects, the gait and balance ability were assessed under 2 conditions: KT and barefoot. Gait and balance ability was assessed using GAITRite system and FDM-S platform. Results: Comparison between KT and barefoot condition, KT condition was significantly higher in velocity, cadence, step length, and stride length than barefoot condition (P<.05). KT condition was significantly lower in CoP path length and sway speed than barefoot condition (P<.05). Conclusion: KT indicated potential as a helpful method for walking and balancing ability in patients with ankle instability after stroke. Therefore, this study recommends KT as an option applicable to the stroke with ankle instability.

TEMPORAL CHANGE OF MAGNETIC SHEAR FREE FROM THE 180° AMBIGUITY

  • MOON Y.-J.;WANG HAIMIN;SPIROCK THOMAS J.;PARK Y. D.
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.3
    • /
    • pp.143-149
    • /
    • 2002
  • In this paper we present a methodology to derive the temporal change of the magnetic shear angle from a series of vector magnetograms, with a high time cadence. This method looks for the minimum change of the shear angle between a pair of magnetograms, free from the $180^{\circ}$ ambiguity, and then accumulates this change over many successive pairs to derive the temporal change of magnetic shear. This methodology will work well if only the successive magnetograms occurred in an active region are well aligned and its helicity sign is reasonably determined. We have applied this methodology to a set of vector magnetograms of NOAA Active Region 9661 on October 19, 2001 by the new digital magnetograph at the Big Bear Solar Observatory (BBSO). For this work we considered well aligned magnetograms whose cross-correlation values are larger than 0.95. As a result, we have confirmed the recent report of Wang et al. that there was the abrupt shear change associated with the X1.6 flare. It is also demonstrated that the shear change map can be an useful tool to highlight the local areas that experienced the abrupt shear change. Finally, we suggest that this observation should be a direct support of the emergence of sheared magnetic fields.

Design of Charge Pump Circuit for PLL (PLL을 위한 Charge Pump 회로 설계 및 고찰)

  • Hwang, Hongmoog;Han, Jihyung;Jung, Hakkee;Jeong, Dongsoo;Lee, Jongin;Kwon, Ohshin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.675-677
    • /
    • 2009
  • 통신기기에서 중요한 기술 중 하나인 PLL(Phase Locked Loop) 회로는 주기적인 신호를 원하는 대로, 정확한 고정점으로 잡아주는데 그 목적을 둔다. 일반적인 구조로 위상주파수검출기(Phase Frequency detector), 루프필터(Loop filter), 전압제어발진기(Voltage Controlled Oscillator), 디바이더(Divider)로 구성되어진다. 그러나 일반적인 PLL 구조로는 지터(jitter)가 증가하고 트랙(tracking) 속도가 느리다는 단점이 있다. 이를 보완하기 위해 루프필터 전단에 차지펌프(Charge pump) 회로를 추가하여 사용하고 있다. 본 논문에서는 CMOS를 이용한 PLL용 차지펌프를 설계하였다. 설계된 회로는 $0.18{\mu}m$ CMOS 공정 기술을 사용하여 CADENCE사의 Specter로 시뮬레이션 하였으며, Virtuso2로 레이아웃 하였다.

  • PDF

The Effect of Arm Swing on Uphill Road Gait in Healthy Adults (팔 흔들기가 건강한 성인의 오르막길 보행에 미치는 영향)

  • Noh, Dong-won;Jeon, Ha-young;Yang, Se-jeong;Lee, Hyeon-hwa;Son, Seong;Cha, Yu-ri
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.2
    • /
    • pp.46-50
    • /
    • 2019
  • Background: The purpose of present study is to effect of arm swing on uphill road gait in healthy adults. Design: Cross-sectional study. Methods: This study was Participated in 15 healthy subjects. The subjects were allowed to walk uphill, about 10m from the line drawn on the floor. The subject stood at the starting line and started by pressing the start button with the signal "start", and I pressed Stop at the last incoming point. Walking with and without arm swing was measured twice in random draws. Results: Walking path with arm swing showed good results in walking path duration, cadence, speed, stride length, and Gait cycle duration rather than uphill walk without arm swing. Conclusion: As a results of this study, The arm swing is important in getting uphill.

Effects of Inclined-treadmill Walking Training with Rhythmic Auditory Stimulation on Balance and Gait in Stroke Patients (리듬청각자극을 동반한 경사 트레드밀 보행 훈련이 뇌졸중 환자의 균형 및 보행에 미치는 영향)

  • Yoon, Sung-Kyeung;Lee, Young-Min
    • PNF and Movement
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 2017
  • Purpose: This study aimed to determine how inclined-treadmill walking training with rhythmic auditory stimulation affects balance and gait in stroke patients. Methods: Ten chronic stroke patients, admitted to B hospital in Gangwon-do between August and October 2015, were trained 5 times per week for 4 weeks; each session lasted 30 minutes. To assess balance and gait before and after the training, the timed up and go (TUG) test, Berg balance scale (BBS), six minute walking test (6MWT), and three-dimensional spatiotemporal gait ability were used to measure the relevant variables. The data were analyzed using the paired t-test, and the statistical significance level was 0.05. Results: There were significant differences in the TUG, BBS, 6MWT, gait speed, cadence, single limb support (SLS), and symmetric index (SI) before and after training (p < 0.05). Conclusion: The results showed that the inclined-treadmill walking training with rhythmic auditory stimulation was effective at improving the balance and walking ability of stroke patients. Hearing training, using one of the basic procedures of proprioceptive neuromuscular stimulation, is considered to be an important aspect.

Effects of Robotic Gait Training with Lower Extremity Restraint on Static Balance, Lower Extremity Function, Gait Ability in Subacute Stroke Patients

  • Kang, Yun-Su;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.270-277
    • /
    • 2021
  • Objective: The purpose of this study is to compare the effect of static balance, lower extremity function, and gait ability between a lower extremity restrain robot gait training and a general robot gait training in subacute stroke subjects. Design: Two-group pretest-posttest design. Methods: A total of 12 subacute stroke patients were randomly divided into an Experimental group (n=6) and a control group (n=6). Both groups were performed for four weeks, three times a week, for 20 minutes. To compare the Static balance function, the center of pressure (COP) path-length and COP velocity were measured. The Fugl-Meyer assessment lower extremity (FMA-LE) were evaluated to compare the Lower Extremity function. 2D Dartfish Program and 10 Meter Walking Test (10 MWT) on Gait ability were evaluated to compare the gait function. Results: In the intra-group comparison, Experimental groups showed significant improvement in COP path-length, velocity, Lower Extremity Function, 10 MWT, Cadence, by comparing the parameters before and after the intervention (p<0.05). Comparison of the amount of change between groups revealed significant improvement for parameters in the COP path-length, velocity, Lower extremity function, 10 MWT by comparing the parameters before and after the intervention (p<0.01). Conclusions: The Experimental group showed enhanced efficacy for variables such as COP path-length, velocity, Lower extremity function, 10 MWT as compared to the control group.

Analysis of Chaotic True Random Number Generator Using 0.18um CMOS Process (0.18um CMOS 공정을 사용한 카오스 난수 발생기 분석)

  • Jung, Ye-Chan;Jayawickra, Chamindra;Al-Shidaifat, AlaaDdin;Lee, Song-Wook;Kahrama, Nihan;Song, Han-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.635-639
    • /
    • 2021
  • As times goes by, a ton of electric devices have been developing. Nowadays, there are many personal electric goods that are connected each other and have important private information such as identification, account number, passwords, and so on. As many people own at least one electric device, security of the electric devices became significant. To prevent leakage of the information, study of Chaotic TRNG, "Chaotic True Random Number Generator", protecting the information by generating random numbers that are not able to be expected, is essential. In this paper, A chaotic TRNG is introduced is simulated. The proposed Chaotic TRNG is simulated with Virtuoso &, a circuit design program of Cadence that is a software company. For simulating the mentioned Chaotic TRNG, setting values, 0V low and 3V high on Vpulse, 1.2V on V-ref, 3.3V on VDD, and 0V on VSS, are used.

Analysis of Step-Down Converter with Low Ripple for Smart IoT Devices (스마트 사물인터넷 기기용 저리플 방식의 스텝다운 컨버터 분석)

  • Kim, Da-Sol;Al-Shidaifat, AlaaDdin;Gu, Jin-Seon;Kumar, Sandeep;Song, Han-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.641-644
    • /
    • 2021
  • Wearable devices and IoT are being utilized in various fields, where all systems are developing in the direction of multi-functionality, low power consumption, and high speed. In this paper, we propose a DC -DC Step-down C onverter for IoT smart devices. The proposed DC -DC Step-down converter is composed of a control block of the power supply stage. It also consists of an overheat protection circuit, under-voltage protection circuit, an overvoltage protection circuit, a soft start circuit, a reference voltage circuit, a lamp generator, an error amplifier, and a hysteresis comparator. The proposed DC-DC converter was designed and fabricated using a Magnachip / Hynix 180nm CMOS process, 1-poly 6-metal, the measured results showed a good match with the simulation results.

The Effect of Lower Limb Resistance Exercise Using a Kinetic Chain on Gait in Stroke Patients (운동 사슬에 따른 하지 저항운동이 뇌졸중 환자의 보행에 미치는 영향)

  • Oh, Yongseop;Hur, Younggoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.165-179
    • /
    • 2019
  • Purpose : The purpose of this study is to improve the stroke patient's gait ability by applying a closed or kinetic chain lower limb exercise Methods : The study subjects were 48 hospitalized hemiplegic patients who agreed to participate in the study. 48 subjects went through the intervention: 24 in the experimental group and 24 in the control group. One set consisted of 10 repeats of the exercise. The subjects performed three sets of the exercise once a day, 5 times a week, for 6 weeks. Results : TUG and FGA were significantly improved in the experimental group. The spatio-temporal gait variables in the experimental group all showed significant improvement. In the control group, velocity, cadence, and double limb support showed significant improvement, Trunk sway angle showed significant improvement in all three axes in both groups. Conclusion : The results of this study indicate that a more positive effect in terms of improvement of the stroke patient's gait ability will be seen for closed rather than open kinetic chain lower limb resistance exercise.