• Title/Summary/Keyword: cable splice

Search Result 11, Processing Time 0.024 seconds

A Study on the Heat Transfer Analysis based on Insulation Thickness Variation of Cable Splice Part (지중케이블 접속부의 절연층 두께변화에 따른 열해석 연구)

  • 최규식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.246-255
    • /
    • 1998
  • The cable cooling through installing the cooling pipe along the transmission cable becomes universal in foreign leading countries, especially in Japan, and, there are so many study results inside and outside of the country. However, the remarkable study result for cooling method of cable splice part is not achieved in spite of its importance. This paper is, therefore, carrys out detailed heat transfer analysis of existing 154kV underground cable-splice, depending on the insulation thickness variation when it is installed in manhole of tunnel whose temperature is maintained as $10^{\circ}C$ using refrigerator. This paper study also the cooling method of underground cable splice based on this result.

  • PDF

A Study on the Affection of Conducting Particle in Cable Splice by Ultrasonic Method (초음파 기법에 의한 케이블 접속재 내부파티클 영향 연구)

  • Park, Chi-Young;Lee, Dong-Zoon;Kwon, Chang-O;Kwak, Hee-Ro;Song, Il-Keun;Park, Ha-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1853-1855
    • /
    • 1997
  • This paper describes the characteristics of partial discharge generated by conducting particle in cable splice using ultrasonic method. For simulating partial discharges generated by defects, outer semi conductor of cable splice as ring share electrode was used. The conductive particle was attached on the surface of cable insulator(XLPE) to examine the affection of conducting particles in cable splice. The correlation between the partial discharge quantity and the magnitude of the ultrasonic signal was investigated as the number, length, diameter and alignment of particle when applied voltage increased.

  • PDF

Characteristics of Injection Molding in Optical Fiber Splice Closure (광섬유 케이블 접속함체의 사출성형 특성 분석)

  • Choi, Jaeyoung;Hong, Minsung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.434-439
    • /
    • 2016
  • Optical fiber splice closure serves to protect connection parts from external environment. Moreover, it functions as a connection, junction, and distribution in diverse surroundings such as aerial, underground, duct, and pole. In this research, first, the optical fiber splice closure, its configuration, and the design problem were briefly investigated. Second, the design and application for in-line cable closure were studied to satisfy its construction and technical features. The injection molding conditions and optimal design were conducted to save time and cost during the manufacturing process. Third, methods to minimize loss via of optical fiber cable while strongly fixing optical fiber cable with optical cable holder to prevent fracture were researched, and tests such as perfect air tightness and mechanical and environmental performance were conducted.

Analysis of the Characteristics of Partial discharge in a Cable splice using a Ultrasonic sensor (초음파 센서를 이용한 케이블 접속재내 부분방전 특성분석)

  • 신동석;이동준;류성식;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.160-162
    • /
    • 2000
  • This paper describes the study on the basic characteristics of discharge generated in cable splices using ultrasonic measurement method. Two kinds of defect which might be existed in a real cable splice were simulated. One is surface discharge moisture and metallic alien substances and the other is partial discharge by metallic particle. As a result, there were some differences in the characteristics of ultrasonic signals according to each defect. Therefore, it was found that is could be possible to protect the failure in cable splices in advance by analyzing the ultrasonic signals coming from the cable splice due to partial discharge.

  • PDF

A Safety Assessment of Splice of 6/10[kV] Class CV Cables with Different Conductor Size (다른 굵기의 6/10[kV]급 CV 케이블 직선접속부 안전성 평가)

  • Jung, Jong-Wook;Kim, Sun-Gu;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.78-84
    • /
    • 2010
  • This paper describes the safety assessment of power cable splices connecting different sized 6/10[kV] class power cables. To assess the safety, AC withstand voltage tests, partial discharge tests and impulse tests were carried out to the cable splice specimens and thermal rise due to overload and cross section of joint were examined as well. As a result, a breakdown due to the $4.5[U_0](27[kV_{ac}])$ application could not found for 5 minutes. Under $1.73[U_0](10.4[kV_{ac}])$ application, partial discharges of 4~8[pC] were detected. In impulse tests, all the specimens withstood to the standard waveforms of $75[kV_{peak}](1.2{\times}50[{\mu}s])$ without any breakdowns. In addition, the temperature on the splice rose by $3[^{\circ}C]$ when the 200[A] flew through the splice for 20minutes, however the thermal rise of $3[^{\circ}C]$ was considered due to the atmospheric temperature. After all the electrical tests, the cross section of the splice was visually examined. The conditions of the conductors of both $185[mm^2]$ and $240[mm^2]$ were good.

Tensile Strength on Connection Socket of Cables (케이블 연결 소켓의 인장강도)

  • Park, Kang-Geun;Lee, Jang-Bok;Ha, Chae-Won;Kim, Jae-Bong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.37-42
    • /
    • 2008
  • Cable member in structure is tension systems in which the load carrying members transmit loads to support system by tensile stress with no compression or flexure allowed. Cable system have been widely used large span structure roof, air-supported structure, prestressed membrane, cable network roof, suspension structures, guyed tower, ocean platforms, suspension bridges. Cable member can transmit loads by the edge connected system such as socket, swaging, mechanical splice sleave, clip, wedge, loop splice etc. This study will shown an experimental results on the strength of connection socket of cables. In the results of experiment, most of cable connection specimen occurred the failure at the connection socket part before the cable arrived at tensile failure load.

  • PDF

An Improvement of Optical Fiber Composite Power Cable On-Line Monitoring System for Underground Distribution Network (지중 배전계통 적용을 위한 광복합 케이블 실시간 감시시스템 개선)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Park, Jung-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.77-83
    • /
    • 2012
  • Since power system is switching to smart grid, on-line monitoring technology has become necessary for underground distribution power cable. Therefore, the application of DTS(Distributed Temperature Sensing) technology using OFCPC(Optical Fiber Composite Power Cable) capable of monitoring underground distribution power cables has been developed. These can bring about reductions in faults and increases in operating capacity of underground distribution system. To date, the test-bed of optical fiber composite power cable on-line monitoring system has been constructed. Then, matters to be improved have been drawn through verification experiments. This paper presents the improvement and experiment results of the optical fiber composite power cable on-line monitoring system to apply to underground distribution lines in the field.

Fabrication of 6 double pancakes Bi-2223 HTS magnet (6 더블팬케이크 Bi-2223 고온초전도 마그네트 제작)

  • Ha, Hong-Soo;Jang, Hyun-Man;Lee, Nam-Jin;Oh, Sang-Soo;Ha, Dong-Woo;Ryu, Kang-Sik;Lee, Hai-Gun;Lee, Jun-Suck
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.373-377
    • /
    • 1999
  • HTS magnet operated at 20${\sim}$40 K was fabricated using three pieces of 100 m Bi-2223 high temperature superconductors fabricated by powder-in-tube process. It was composed of 6 double pancakes with 75 ID. and 113 OD. connected by lab splice. Coil I$_c$ of each DP.(double pancake) obtained for a 140 turn, fabricated using react and wind procedure was 6${\sim}$8 A at 77 K, self field. The maximum field was measured 0.06 T at lop = 5 A, 77 K. The joint resistance due to lap splice of HTS tapes affect badly to operate HTS magnet with persistent current mode, total effective magnet resistance included lap splice was 55 ${\mu}$ ${\omega}$ at 77 K.

  • PDF

장파장 다중모드 광섬유 통신시스템의 실용시험

  • Kim, Yong-Hwan;Lee, Seong-Eun;Kim, Hong-Man;Park, Chang-Su;Won, Yong-Hyeop;An, Jong-Pyeong;Yu, Tae-Hwan;Sin, Dong-Hyeok;Seo, Wan-Seok;Gang, Min-Ho
    • ETRI Journal
    • /
    • v.6 no.2
    • /
    • pp.15-17
    • /
    • 1984
  • A long-wavelength ($1. 3\mum$) multimode fiber-optic transmission system has been developed and the field trial system has been installed over 17.3km distance in Daejeon Area by KETRI. The 45Mb/s and 90Mb/s system operate with BER $10^-9$over 17.3km distance, and they successfully operate on the route of 34. 6km length when the fiber cable is simply connected at one end. Average loss of the fiber cable shows 0. 81dB/km including splice loss and the average bandwidth over the 17. 3km distance is 170MHz.

  • PDF

Optical Line Remote-Monitoring System Using Reflecting Filter (반사필터를 이용한 광선로 원격감시 시스템)

  • Jung, So-Ki;Cha, Kyoung Cheon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.6
    • /
    • pp.357-364
    • /
    • 2014
  • In this paper deals with PON Remote monitoring solution using Reflecting Filter. The current FTTH-PON can not be monitored in real time that Optical cable fault and Quality degradation of Splitter. To solve this problem, Monitoring can make Feeder Network and Splitter that Reflecting filter development using the basic structure of Fiber Bragg grating. Reflecting Filter is Quality Monitoring System shall provide tools for user to view and analyze degradation of cables and splitter in particular predict any gradual component degradation(Optical cable bending, splice, connector, etc) before it becomes service impacting. The Reflecting Filter solution is splitter down and confirm the fault location of optical cable and it will send central control station can be monitored system an alarm to the OLT. In other words, wavelength side branches Mating existing communication affairs (Coupler) using the core of one optical wavelength for live monitoring two wavelengths and sends the subscriber side modem and aggregation switch device remotely using a reflective optical line filter monitoring the study of the system. this study can development of Reflecting filter improve the average processing time of Optical cable fault and efficient Maintenance of the network.