• Title/Summary/Keyword: cable failure analysis

Search Result 89, Processing Time 0.024 seconds

Non-linear stability analysis of a hybrid barrel vault roof

  • Cai, Jianguo;Zhou, Ya;Xu, Yixiang;Feng, Jian
    • Steel and Composite Structures
    • /
    • v.14 no.6
    • /
    • pp.571-586
    • /
    • 2013
  • This paper focuses on the buckling capacity of a hybrid grid shell. The eigenvalue buckling, geometrical non-linear elastic buckling and elasto-plastic buckling analyses of the hybrid structure were carried out. Then the influences of the shape and scale of imperfections on the elasto-plastic buckling loads were discussed. Also, the effects of different structural parameters, such as the rise-to-span ratio, beam section, area and pre-stress of cables and boundary conditions, on the failure load were investigated. Based on the comparison between elastic and elasto-plastic buckling loads, the effect of material non-linearity on the stability of the hybrid barrel vault is found significant. Furthermore, the stability of a hybrid barrel vault is sensitive to the anti-symmetrical distribution of loads. It is also shown that the structures are highly imperfection sensitive which can greatly reduce their failure loads. The results also show that the support conditions pose significant effect on the elasto-plastic buckling load of a perfect hybrid structure.

Evaluation of Insulation Deterioration for the Development of SVM Algorithm to Diagnose OF Cable (OF 케이블 진단용 SVM 알고리즘 개발을 위한 절연열화 평가)

  • Kwak, Byeong Sub;Jun, Tae-Hyun;Kim, Ah-Reum;Park, Hyun-joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.263-273
    • /
    • 2019
  • South Korea's OF cable is reaching its expected design life of 30 years, and as a result, the risk of failure is increasing. Therefore, it is necessary to diagnose the long-term operating OF cables through accurate diagnosis at the right time to prevent the failure. Currently, the KEPCO periodically conducts DGA. However, the gas found in DGA is caused by oil deterioration as well as insulation paper. Therefore, the analysis of the degree of polymerization and furan compounds which is an evaluation of insulation paper considered to be the life of OF cables is required. In addition, the results of the evaluation of deterioration of insulation paper need to be checked for correlation with the results of DGA. In this study, DGA carried out through GC, the degree of polymerization was analyzed using an automatic viscometer, and HPLC was used to detect the furan compounds. In addition, the obtained results were applied to the SVM technique, which was recently introduced to determine abnormalities in OF cable. And the results which were accurate and reliable were obtained.

The Analysis and Adjustment for the Control Parameter of HVDC System (HVDC 시스템의 제어 게인에 대한 분석 및 정정)

  • Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.184-191
    • /
    • 2006
  • This paper deals with the HVDC system fault analysis and the tuning of the control parameter. This paper is based on the actual cable fault which was caused by the overvoltage due to commutation failure. In order to analyze the fault, the detailed PSCAD/EMTDC model which the sampling time is $50{\mu}s$, was made. Finally, the control parameter of HVDC system was tuned.

Robust Design for Parts of Induction Bolt Heating System (유도가열시스템의 구성부품에 대한 강건설계)

  • Kim, Doo Hyun;Kim, Sung Chul;Lee, Jong Ho;Kang, Moon Soo;Jeong, Cheon Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.10-17
    • /
    • 2021
  • This paper presents the robust design of each component used in the development of an induction bolt heating system for dismantling the high-temperature high-pressure casing heating bolts of turbines in power plants. The induction bolt heating system comprises seven assemblies, namely AC breaker, AC filter, inverter, transformer, work coil, cable, and CT/PT. For each of these assemblies, the various failure modes are identified by the failure mode and effects analysis (FMEA) method, and the causes and effects of these failure modes are presented. In addition, the risk priority numbers are deduced for the individual parts. To ensure robust design, the insulated-gate bipolar transistor (IGBT), switched-mode power supply (SMPS), C/T (adjusting current), capacitor, and coupling are selected. The IGBT is changed to a field-effect transistor (FET) to enhance the voltage applied to the induction heating system, and a dual-safety device is added to the SMPS. For C/T (adjusting current), the turns ratio is adjusted to ensure an appropriate amount of induced current. The capacitor is replaced by a product with heat resistance and durability; further, coupling with a water-resistant structure is improved such that the connecting parts are not easily destroyed. The ground connection is chosen for management priority.

Reliability Analysis for Stress Corrosion Cracking of Suspension Bridge Wires (현수교케이블의 응력부식에 관한 신뢰성해석)

  • Taejun;Andrzej S. Nowak
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.537-544
    • /
    • 2003
  • This paper deals with stress corrosion cracking behavior of high strength steel exposed to marine environments. The objective is to determine the time to failure as a function of hydrogen concentration and tensile stress in the wires. A crack growth curve is modeled using finite element method (FEM) program. The coupled hydrogen diffusion-stress analyses of SCC were programmed separately. The first part is calculating stress and stress intensity /sup 1)/factor of a cylindrical shell, prestressing tendon or suspension bridge wires, from the initiation of cracks to rupture. Virtual crack extension method, contour integral method, and crack tip elements are used for the calculation of stresses in front of the crack tip. Comparisons of the result show a good agreement with the analytical equations and wire tests. The second part of the study deals with the programming of hydrogen diffusion, affected by hydrostatic stress, calculated at the location of boundary of plastic area around the crack tip. The results of paper can be used in the design and management of prestressed structures, cable stayed and suspension bridges. Time dependent correlated parallel reliabilities of a cable, composed of 36 wires, were evaluated by the consideration of the deterioration of stress corrosion cracking.

  • PDF

A Study on the Characteristics of Behavior of Block-type Reinforced Earth Retaining Wall Considering Failure Surface (파괴면을 고려한 블록식 보강토 옹벽의 거동 특성 연구)

  • Yoon, Won-Sub;Park, Jun-Kyu;Chae, Young-Su
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.3
    • /
    • pp.13-26
    • /
    • 2016
  • In this study, more economical than conventional reinforced soil retaining walls, we compared the behavior characteristic about the safety block type numerically for reinforced retaining wall. In this study, reinforced soil retaining wall, first, was integrated a wall putting shear key on the blocks. Second, construction reinforcement focused on the theoretical failure surface was satisfied with the stability of a retaining wall reinforced by a shear plane. when analyzing, element of using reinforcement was carried out a numerical analysis for the cable element and the strip element, and they were analyzed under the conditions according to the stiffener length, distance, with or without shear key. Analysis for the integration of the front wall was reinforced soil retaining walls by installing a larger displacement shear key confinement effect, if reinforced construction and reinforcement with 1 interval and 2 interval, the failure surface was bigger displacement constraints. Generating a deformation amount was smaller than the generation amount of deformation accrued during construction of AASHTO so that it was stable.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

Insulation Aging Characteristic Assessment on the Power cables with the Comparative Analysis Between Destructive and Nondestructive Diagnosis (파괴 및 비파괴진단 비교분석을 통한 케이블 열화특성평가)

  • Yi, Dong-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.104-108
    • /
    • 2009
  • The insulation aging characteristics and structural analysis test were performed to analyze the correlations among the insulation deterioration, diagnostic results and the breakdown strength for the underground power cables. From the results of the degree of crosslinking test, hot-oil test etc., it could be confirmed that there were no manufacturing defects in the power cables under test. From the results of the water tree test and chemical structural analysis, it could be confirmed that the aging status of cable under test were very poor, especially for B-Phase and the degree of aging was increased in the orders of A, C and B-phase. From the above results, it could be concluded that the insulation aging characteristic analysis results were well consistent with the diagnostic and breakdown test results, and also confirmed that the diagnostic system under consideration was successful to discriminate the bad cables which is likely to cause cable system failure.

A numerical study on pull-out behaviour of cavern-type rock anchorages (수치해석에 의한 암반상의 지중정착식 앵커리지 인발 거동 연구)

  • Hong, Eun-Soo;Cho, Gye-Chun;Baak, Seng Hyoung;Park, Jae-Hyun;Chung, Moonkyung;Lee, Seong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.521-531
    • /
    • 2014
  • This paper is a study for behaviour of cavern type anchorage tunnels for suspension bridges with cable tension. Anchorage behaviour, design method for anchorage, and failure surface angle, ${\delta}$ are analyzed by comparing numerical analysis results and ultimate pullout capacities($P_u$) using bilinear corelation equation. Results show that design depths for cavern type anchorage tunnels are easily checked with linear relationships for $P/{\gamma}/H$ vs. displacement and $P_u/{\gamma}/H$ vs. H/b. The analysis results of maximum shear strain distribution and plastic status show that failure shapes are closer to circular arc model than soil cone model which frequently used. To an easy calculation of the ultimate pullout capacity, we propose a simple bilinear failure model in this study. The calculated ultimate pullout capacities from the proposed bilinear corelation equation using two failure angles results are similar to the ultimate pullout capacities from numerical analysis.

Study of Injection Molding Process of Shift Lever Using Injection Molding Analysis (사출성형해석을 통한 자동차 레버쉬프트의 사출공정에 관한 연구)

  • Park, Chul-Woo;Lee, Boo-Youn;Lee, Sang-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.7-13
    • /
    • 2015
  • The production processes were reviewed through the injection analysis of the shift lever as a core component of an auto lever installed in the automatic transmission of cars. The injection analysis was carried out for the shift lever and rod among the components in a shift lever module. The shift lever and rod are designed for injection molding with the insertion of a tube, a pin cable plate, and a steel rod for securing the strength of the product. The charging time, failure of injection molding, weld line, air trap, and deformation were reviewed according to this insert. Analyses on various gate positions were carried out for reviewing the cultivation and deformation of fiber around major components, such as the generation section of manipulation feeling and assembly section, so that optimal gate conditions might be reviewed and reflected in the mold design. Finally, we plan to compare the analysis results with the production of trial products.