• 제목/요약/키워드: bypass switch

검색결과 32건 처리시간 0.019초

ATM 스위치에서의 여분 경로 전송 메커니즘 (Alternate path transfer mechanism on ATM switch)

  • 이주영;임인칠
    • 전자공학회논문지S
    • /
    • 제34S권8호
    • /
    • pp.45-55
    • /
    • 1997
  • To design a ATM Switch which ahs advantages in high sped packet switching, it is essential to set multiple paths between input ports and output ports and to design a new packet transfer technique on that paths for decreasing Packet Loss by conflicts in internal Switch Plane. We propose new packet transfer method, Alternate Path Transfer Mechanism by Dynamic Bypass Transfer Method which can solve conflict problem in Banyan network easily. Proposed ATM Switch consists of Banyan networks, Input/Ouput Port, Bypass Link, and Bypass Link Controller. Packets caused conflicts in SEs have another chances of packet transfer over alternate switching planes by using this mechanism.

  • PDF

아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법 (The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control)

  • 김석희;최병민;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.

바이패스 스위치와 저항센서를 이용한 저손실 전류 측정방법 (Low Power-loss Current Measurement Technique Using Resistive Sensor and Bypass Switch)

  • 이화석;다니엘;박종후
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.416-422
    • /
    • 2012
  • This paper proposes a low power-loss current measurement using a resistor and bypass switch. Conventional current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. The propose measurement works for discrete-time sampling of current sensing. Even while the analog-digital conversion does not occur at the controller, the sensing voltage across the sensor still causes ohmic conduction loss without information delivery. Hence, the bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 90[W] prototype hardware has been implemented for photovoltaic MPPT experimental verification of the proposed low power-loss current measurement technique. From the results, it can be seen that PV power observation is successfully done with the proposed method.

Low-Power Cool Bypass Switch for Hot Spot Prevention in Photovoltaic Panels

  • Pennisi, Salvatore;Pulvirenti, Francesco;Scala, Amedeo La
    • ETRI Journal
    • /
    • 제33권6호
    • /
    • pp.880-886
    • /
    • 2011
  • With the introduction of high-current 8-inch solar cells, conventional Schottky bypass diodes, usually adopted in photovoltaic (PV) panels to prevent the hot spot phenomenon, are becoming ineffective as they cause relatively high voltage drops with associated undue power consumption. In this paper, we present the architecture of an active circuit that reduces the aforementioned power dissipation by profitably replacing the bypass diode through a power MOS switch with its embedded driving circuitry. Experimental prototypes were fabricated and tested, showing that the proposed solution allows a reduction of the power dissipation by more than 70% compared to conventional Schottky diodes. The whole circuit does not require a dedicated DC power and is fully compatible with standard CMOS technologies. This enables its integration, even directly on the panel, thereby opening new scenarios for next generation PV systems.

단조 버퍼링 방식을 이용한 Banyan형 ATM 스위치의 성능평가 (The Performance of Banyan Type ATM Switch using Monotonic Buffering Scheme)

  • 김범식;우찬일;신인철
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 1997년도 추계학술대회 발표논문집:21세기를 향한 정보통신 기술의 전망
    • /
    • pp.147-161
    • /
    • 1997
  • In the future, the performance of B-lSDN offering the multimedia and a various service depends on the performance of switch that is the important factor consisting of network. Bufferless banyan network consisted of MIN(multistage interconnection network) selected for- the fabric of ATM switch and has a limitation of performance because of blocking. Input buffered banyan networks with FIFO(first-in first-out) buffering scheme for the reduction of blocking and the cell bypass queueing theory for the reduction of HOL(head of line) blocking were seperately compared of the performance of switch. Specially input buffered banyan networks were applied monotonic buffering scheme that was proposed. As a result of simulation, Buffered Banyan Network with cell bypass queueing theory showed better performance than FIFO type input buffered Banyan network. Monotonic increase buffering scheme showed better performance than Monotonic decrease buffering scheme.

  • PDF

Coronary Artery Bypass Grafting in an Infant after an Arterial Switch Operation

  • Choi, Wooseok;Pyo, Wonkyung;Choi, Eun Seok;Chung, Cheol Hyun
    • Journal of Chest Surgery
    • /
    • 제54권2호
    • /
    • pp.146-149
    • /
    • 2021
  • Coronary artery bypass grafting (CABG) is rarely performed in infants because of its technical difficulty and unclear long-term results. A 90-day-old male infant weighing 3.5 kg who underwent an arterial switch operation (ASO) for transposition of the great arteries developed left coronary artery insufficiency despite augmentation and reimplantation of the left coronary button. On-pump beating heart CABG was performed using an internal mammary artery graft to revascularize the left anterior descending artery. Postoperative computed tomography angiography revealed that the graft was patent. At 7 months postoperatively, the patient weighed 8.5 kg, and echocardiography revealed good ventricular function. CABG can be an alternative treatment for post-ASO coronary complications in early infancy.

Switch를 이용한 1.5 GHz 대역 고출력 Cavity 기반 Tunable Filter (High Power Cavity Type Tunable Filter Using Switch for 1.5 GHz Band)

  • 안세훈;이민호;박종철;정계택
    • 한국전자파학회논문지
    • /
    • 제27권1호
    • /
    • pp.1-7
    • /
    • 2016
  • 본 논문에서는 기계식 스위치를 이용한 1.5 GHz 대역 고출력 Cavity 기반 튜너블 필터를 설계하고 제작하였다. 불요파를 제거하기 위해 저역통과필터를 삽입하고, 출력을 추출하기 위해 Coupler를 내장하였으며, 고출력에 적합한 기계식 스위치를 사용하여 튜너블 필터의 시스템을 구성하였다. 저역통과필터는 4~12.75 GHz까지 40 dB 이상의 감쇄 특성을 얻었고, Coupler는 40 dB의 Coupling Value와 55 dB 이상의 Coupling Isolation을 얻었다. 제작된 기계식 스위치를 사용한 튜너블 필터 시스템은 1,495.9~1,510.9 MHz Bypass Mode에서 0.88 dB, 1,495.9~1,500.9 MHz Fil Mode에서 3.29 dB의 삽입손실 특성 및 중심주파수 1,498.4 MHz에서 132 W의 출력전력과 10 ms 이하의 스위칭 절환속도를 얻었다.

이종초전도 코일을 이용한 하이브리드형 한류기의 제작 및 단락실험 (Fabrication and Small scale Short Circuit Tests of Hybrid Fault Current Limiter Employing Asymmetric Non-Inductive Coil and Fast Switch)

  • 장재영;김영재;나진배;최석진;이우승;이창영;박동근;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.41-45
    • /
    • 2011
  • Hybrid fault current limiters (FCL) have been researched at Yonsei University. The hybrid FCL has advantages such as having a rapid response to a sudden fault situation and a fast recovery time from a quench. It consists of an asymmetric HTS coil, a switching module, and a bypass reactor. The asymmetric HTS coil is wound with two different types of HTS wires in an opposite direction so that it has nearly zero inductance at the superconducting state. When the quench occurs at the fault state, a strong magnetic field is generated from the asymmetric coil because of different quench characteristics of two HTS wires, and then a repulsive force is induced in the switching module. The force opens the switch and the fault current is pushed into the bypass reactor. In this research, we analyzed the cause of the repulsive force and confirmed, experimentally and computationally, that the magnitude of a repulsive force is varied by changing the gap distance between the asymmetric coil and the switching module. By using the FEM simulation, we calculated the repulsive force with respect to the gap distance and verified that the effect of the gap distance. Then, short circuit test was carried out to confirm the correct operation of the fast switch.

수동 바이패스 필터를 이용한 단상 무변압기형 인버터 (Single-Phase Transformerless Inverter using Passive Bypass Filter)

  • 양민권;허준;이명철;김유진;최우영
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.129-138
    • /
    • 2018
  • Previous single-phase transformerless inverters used active bypass switching circuits that need auxiliary power switches to minimize ground leakage current. However, switching and gate driving losses are increased due to the use of additional power switches. To cope with this drawback, this work proposes a transformerless inverter using a passive bypass filter without any auxiliary power switch. The operation and control of the proposed inverter are described. The ground leakage current characteristics are analyzed for the proposed inverter with the passive bypass filter. The experimental results of the proposed inverter for a 1.0kW prototype system are presented.

USP의 신뢰성 향상을 위한 독립제어 고속절환장치 (Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply)

  • 정현철;현동석
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.278-286
    • /
    • 2008
  • 본 논문은 대용량 더블컨버젼 방식 $30^{\sim}500[KVA]$ 무정전전원공급장치 UPS(Uninterruptible Power Supply)의 고장발생유형과 출력정지현상의 원인을 살펴보고, 부하 측면에서 전원공급의 신뢰성을 높일 수 있는 고장 검출방식을 제안한다. 인버터 출력의 전원품질을 검출하여 이상으로 판단 시 바이패스 시키는 방식의 기존 UPS 제어방식의 경우, 만일 내부(전력변환소자, 컨트롤러, CPU)소손이 발생되는 경우에는 부하전원 공급이 중단되는 현상이 발생되었고 이를 실험파형과 장비 운용결과를 통하여 증명하였다. 본 논문은 이러한 사고의 경우에도 출력전원의 공급에는 문제가 없도록 하기 위하여 기존 UPS의 제어시스템과는 별도로 독립적으로 고장검출장치, 바이패스 제어장치, 3중전원공급장치를 구축한 상태에서, 고장검출위치를 최종출력스위치 전단으로 변경하고, 고장판단 기준값을 기존 UPS제어시스템과 충돌이 없도록 변경하고, 사고확산을 차단할 수 있는 장치를 하였다. 이 시스템을 통신전원공급용 UPS 242대에 적용한 결과 2006년 이후 2년간 서비스장애가 발생되지 않았다.