DOI QR코드

DOI QR Code

Low Power-loss Current Measurement Technique Using Resistive Sensor and Bypass Switch

바이패스 스위치와 저항센서를 이용한 저손실 전류 측정방법

  • Received : 2012.07.16
  • Accepted : 2012.08.27
  • Published : 2012.10.20

Abstract

This paper proposes a low power-loss current measurement using a resistor and bypass switch. Conventional current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. The propose measurement works for discrete-time sampling of current sensing. Even while the analog-digital conversion does not occur at the controller, the sensing voltage across the sensor still causes ohmic conduction loss without information delivery. Hence, the bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 90[W] prototype hardware has been implemented for photovoltaic MPPT experimental verification of the proposed low power-loss current measurement technique. From the results, it can be seen that PV power observation is successfully done with the proposed method.

Keywords

References

  1. Hwa-Seok Lee, I. Daniel Thena Thayalan, Joung-Hu. Park, "High efficiency current measurement using resistor and bypass switch," 2012 Power Electronics Annual Conference, pp. 103-104.
  2. Do-Yun Kim, "Phase Current Sensing Method Using Three Shunt Resistor for Three Phase Inverter," 2011 Power Electronics Annual Conference, pp. 235-236.
  3. K.H Yeon, S.D Kim, D Son, "Current Sensor Based on Hall Sensor and Magnetic Core for Hybrid Vehicle," ICAUMS2010 International Conference of Aums, December 5-8. 2010.
  4. Hwa-gene Lee, Kwon Soo Han, Kyu- Tae Kim, "Precision evaluation of High DC current shunt," 2011 KIEE Annual Conference, pp. 227-229.
  5. K-T. Kim, "Precise Measurement of High Current Shunt Resistance," 2005 KIEE Annual Conference, pp. 403-406.
  6. Min-Ho Song, "Current Measure using Fiber-Optic CT," KIIEE Annual Conference, pp. 28-33, 2004. 7.
  7. Ho-Gi Kim. Gu-Bae Kang. Dong-Jin Nam, "Coreless Hall Current Sensor for Automotive Inverters Decoupling Cross-coupled Field," Journal of Power Electronics, January 2009.
  8. E. R. Olson and R. D. Lorenz, "Effective use of minaiature, multi-point, field-base current sensors witout magnetic cores," in Conf. Rec. IEEE-IAS Annu Meeting, pp. 1426-1433, 2007.
  9. Byung-Geuk Cho, Jung-Ik Ha, Seung-Ki Sul, "Voltage Injection Method for Boundary Expansion of Output Voltages in Three Shunt Sensing PWM Inverter," IEEE ECCE, pp. 411-415, 2011.
  10. Jung-Ik Ha, "Voltage Injection Method for Three-Phase Current Reconstruction in PWM Inverters Using a Single Sensor," IEEE Trans. Power Electronics, Vol. 24, Issue.3, pp. 767-775, March 2009. https://doi.org/10.1109/TPEL.2008.2009451
  11. R. P. Singh and A. M. Khambadkone. "Giant Magneto Resistive(GMR) Effect Based Current Sensing Technique for Low Voltage/High Current Voltage Regulator Modules," IEEE Trans. Power Electron., Vol. 23, pp. 915-925, Mar. 2008. https://doi.org/10.1109/TPEL.2007.915771
  12. N. McNeill, G. Iordanidis, D. Holliday, and P. Mellor, "Low-cost high-bandwidth current transducer for automotive applications," IEEE Trans. Power Electron, Vol. 21, pp.832-835, Sept. 2006. https://doi.org/10.1109/TPEL.2006.875564
  13. Ji-Hoon Jang, Seung-Ki Sul, Yo-Chan Son, "Current Measurement Issues in Sensorless Control Algorithm using High Frequency Signal Injection Method," IEEE IAS Annual Meeting, Vol. 2, pp.1134-1141. 2003.
  14. Bob Mammano, "Current Sensing Solutions for Power Supply Designers," 2001 Texas Instruments Incorporated document.
  15. Texas Instruments "Understanding Data Converters," Application report, 1995.
  16. Sanjaya maniktala, "Troubleshooting Switching Power Converters," Elsevier, 2008, pp. 39-42.
  17. D. W. Chung, S. K. Sul, "Analysis and Compensation of Current Measurement Error in Vector-Controlled AC Motor Drives," in proceedings of the 1999 Industrial Electronics Society Anual Conference of the IEEE, vol. 3, pp. 1458-1463, 1999.
  18. Texas Instuments F2833x study material for CCS 3, Texas Instruments Incorporated European Customer Traning Cnetre & University of Applied Sciences Zwickau.
  19. Seung-Ho Song, Jong-Woo Choi, Seung-Ki Sul, "Current Measurements in Digitally Controlled AC Drivers," IEEE Industry Applications Magazine, Vol. 6, pp. 51-62, 2000. https://doi.org/10.1109/2943.847916
  20. Doo-Yong Jung, "Soft Switching Boost Converter using a Single Switch," 2009 Power Electronics Annual Conference, pp. 211-219
  21. Jin-Bae Kim, "Soft Switching DC/DC Converter Using Boost," 2009 Power Electronics Annual Conference, pp. 436-437.

Cited by

  1. Direct MPPT Algorithm for PV Sources With Only Voltage Measurements vol.30, pp.12, 2015, https://doi.org/10.1109/TPEL.2015.2389194
  2. Low-Cost High-Efficiency Discrete Current Sensing Method Using Bypass Switch for PV Systems vol.63, pp.4, 2014, https://doi.org/10.1109/TIM.2013.2285791
  3. The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control vol.19, pp.2, 2014, https://doi.org/10.6113/TKPE.2014.19.2.133