제3회 전국기술사대회 특집(3차분) - 초고층 건축물의 피난시설 계획수립의 대안 - 소방 - (The 3rd National Conference Of Professional engineers - Proposal in Planning of Evacuation Facilities in High-Rise Buildings)

  • 이경하
    • 기술사
    • /
    • 제42권6호
    • /
    • pp.23-27
    • /
    • 2009
  • In regard to the planning of building evacuation in high-rise buildings, the current ruling provisions in domestic Acts are divided into the Building Act and the Fire Services Act to stipulate the requirements of evacuation facilities and the egress plan for fire safety. This fact of two divided Acts is the one reason that the planning of complete building evacuation in case of fire in the high-rise buildings could not have been accomplished successfully on the basic design basis with the current applying procedure of the two Korean Acts.

  • PDF

고층아파트 화재시 발코니 확장에 따른 화재 위험성에 관한 실험 연구 (An Experimental Study of Fire Risk Characteristic by Extended Balcony of High-Rise Apartments in Fire)

  • 김우석;김화중;이광원;이지희
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.65-71
    • /
    • 2012
  • Changes in the styles of communities are leading of increases in the number of high-rise apartments and commercial-apartment structures. Tall high-rise structures, while presenting unique economies of scale and cost effectiveness, tend to be highly engineered and complex structures. In the event of a fire, this complexity in design also results in a complexity in the behavior of fire propagation and control. High-rise structures are among the most potentially dangerous due to the high population density in the building, and the inherent limitations on evacuation and on fire control services. One of the most critical points of fire propagation is the movement of fire through the outer wall structures. Controlling such propagation is essential in controlling the spread of the fire throughout the building itself, as well as controlling the potential for its spread to adjacent buildings. In this study, we will be examining the potential for fire control design and effects mitigation using a 1/4.5 scale model. The primary focus of the study will be the effects of extended balconies into the structure of high-rise apartments. The authors will also consider the effectiveness of reduced-scale model tests.

Evacuation Safety Evaluation According to Slope of the School Ramps

  • Choi, Chang-Jun;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.184-196
    • /
    • 2021
  • This study, in order to evaluate the safety of evacuation by comparing and analyzing the RSET according to the slope change of the ramp, which is a vertical evacuation route in case of fire in a high school building, Evacuation simulation was run the Pathfinder program changed the slope of the ramp to 10°, 15°, and 20° for each male students and female students. In the case of female students, it was analyzed that when the final RSET slope was 15°, 25.7 seconds were shorter than when 10°, and 4.2 seconds were shorter than when 20°. Male students also found that when the final RSET slope was 15°, 23.8 seconds were shorter than when 10°, and 5.4 seconds shorter than when 20°. It was analyzed that even if the number of participants was increased and the evacuation simulation was executed, the safety of evacuation could be improved when the slope of the slope is 15° as the RSET when the slope of the slope is 15° is shorter than that of 10° and 20°.

화재안전 데이터베이스 구축을 위한 콘칼로리미터의 활용성 연구 (Study on the Application of Cone Calorimeter for Building of Data-Bases for Fire Safety)

  • 홍화영;이종성;박수진;권인규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.325-329
    • /
    • 2011
  • 오늘날 대부분의 화재조사의 기본 원칙은 숫자를 찾는 데 목적이 있고, 화재의 중요한 양상을 묘사할 수 있는 물리학적으로 정확한 경험식과 하나의 모델로 바꾸는 데 가치를 두고 있다. 화재는 일반적으로 화재 초기에 발생하는 열이 상호작용 과정에 의해 성장하며, 이 간단한 과정이 화재 성장률을 결정하며, 그 예측을 어렵게 한다. 그러므로 화재성장에서 대부분의 모델은 경험으로부터 정해지게 되는데, 그 모델은 매우 제한적이다. 콘칼로리미터는 특별히 노출된 부분에서 중요한 재료 특성의 변화 수치를 얻을 수 있으며, 측정기준은 발화, 질량손실률, 열 발생률, 연기 발생률, 가스 분석 등이며, 이 모든 측정은 테스트의 시작에서 끝날 때까지 실행되며, 이는 발화 전, 발화 후를 모두 포함한다. 국내외 콘칼로리미터의 연구를 비교, 분석하여 화재안전 데이터베이스 구축에 활용되는 콘 칼로리미터의 중요성 평가를 본 연구의 목적으로 한다.

  • PDF

NFPA 101 피난 안정성 평가에 기초한 피난 규정 개선 방향 연구 (A Study on the Improvement of Means of Egress Based on NFPA 101)

  • 강경호;정석환
    • 대한안전경영과학회지
    • /
    • 제25권1호
    • /
    • pp.31-38
    • /
    • 2023
  • The object of this study is to evaluate whether the means of egress of Jechon Sports Center and Miryang Sejong Hospital, where massive fire human casualties occurred in 2017 and 2018 respectively, comply with NFPA 101(Life Safety Code), and to suggest the need for supplementation of domestic means of egress regulations. The study evaluated the number and arrangement of the means of egress, travel distance, common path of travel, dead end and discharge from exit for each building by applying the means of egress regulations of NFPA 101. As a result of the evaluation through NFPA 101, the travel distance was appropriate, but some of the other items except for the travel distance did not meet NFPA 101. The regulations that need to be supplemented are 1)occupant load calculation 2)egress capacity calculation 3)continuous concept of means of egress 4)concept of common path of travel. It is especially necessary to revise the requirement for fire door of the evacuation floor(normal 1st floor) of the stairwell in case of below the five story building.

보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구 (A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility)

  • 박재성
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.93-102
    • /
    • 2009
  • 최근 보육시설의 확충과 보육환경의 개선, 보육서비스 질 향상에 대한 사회적 욕구는 급속히 증가하고 있으며, 특히 화재 등으로부터 안전환경 확보가 범국가적 이슈로 대두되고 있다. 보육시설은 영유아 등 재실자의 대부분이 피난능력이 떨어지는 재해약자로 구성되어 건물 내 설치층수, 피난시설의 설치 적정성 등이 피난안전을 좌우하는 중요한 요소이다. 본 연구에서는 보육시설 설치현황, 국내외 관련 기준의 비교분석, 피난 관련 시설의 실태조사 등을 통하여 보육시설 피난안전성 측면에서의 문제점과 개선요소를 파악하였다. 그 결과 화재안전 관련 법규정의 체계화, 비상재해대비시설의 설치기준 및 관리에 대한 소방기관과의 연계, 스프링클러 등 보다 강화된 소방설비 설치규정의 개선, 화재위험시설과 동일 건물 내 설치금지 등이 필요한 것으로 분석되었다.

퍼지추론을 이용한 지식기반 전기화재 원인진단시스템 (A Knowledge-based Electrical Fire Cause Diagnosis System using Fuzzy Reasoning)

  • 이종호;김두현
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.16-21
    • /
    • 2006
  • This paper presents a knowledge-based electrical fire cause diagnosis system using the fuzzy reasoning. The cause diagnosis of electrical fires may be approached either by studying electric facilities or by investigating cause using precision instruments at the fire site. However, cause diagnosis methods for electrical fires haven't been systematized yet. The system focused on database(DB) construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. The cause diagnosis system for the electrical fire was implemented with entity-relational DB systems using Access 2000, one of DB development tools. Visual Basic is used as a DB building tool. The inference to confirm fire causes is conducted on the knowledge-based by combined approach of a case-based and a rule-based reasoning. A case-based cause diagnosis is designed to match the newly occurred fire case with the past fire cases stored in a DB by a kind of pattern recognition. The rule-based cause diagnosis includes intelligent objects having fuzzy attributes and rules, and is used for handling knowledge about cause reasoning. A rule-based using a fuzzy reasoning has been adopted. To infer the results from fire signs, a fuzzy operation of Yager sum was adopted. The reasoning is conducted on the rule-based reasoning that a rule-based DB system built with many rules derived from the existing diagnosis methods and the expertise in fire investigation. The cause diagnosis system proposes the causes obtained from the diagnosis process and showed possibility of electrical fire causes.

′화재예방법규′의 규제완화가 화재발생에 미치는 영향 -영국 사례분석 - (Deregulation of the Fire Prevention Legislation; and Its Impact on Fire Occurrence - Case of the United Kingdom -)

  • 이재열
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.13-19
    • /
    • 2001
  • OECD는 규제개혁을 '보다 나은 규제'와 '규제폐지'로 구분하고, 환경 및 안전 분야의 규제는 지속되어야 한다고 강조한다. 반면에, 1990년대에 진행된 한국소방의 규제개혁은 일방적인 규제의 완화 또는 폐지라는 방향으로 진행되는 매우 기이한 현상을 나타내고 있다. 영국 소방예방법규의 경우, 1971년 화재예방법의 제정 이후 대형화재의 발생에 대응하여 지속적으로 예방법규를 강화해 오고 있으며, 1991년 건축령에서는 주택을 포함하여 모든 건물에 대하여 각층에 최소 한 개의 연기경보기를 설치할 것을 의무화하고 있다. 이 연구는 영국에서의 소방예방법규의 강화가 소방안전을 제고 시켰다는 것을 보여 주고 있는데, 이것은 한국소방에 시사하는 바가 크다. 한국소방의 경우 화제로부터 시민의 생명과 재산을 보호하기 위해서 '안전, 보건, 환경과 관련된 규제의 질을 개선한다'는 규제개혁위원회의 규제개혁 기본방향이 철저히 준수되어야 하며, 비록 규제개혁의 전체적 전략이 모든 규제를 감소시키는 것일지라도 안전에 관한 규정은 오히려 증가시킬 수 있다는 기본방향의 유연성이 확보되어야 한다.

  • PDF

프리캐스트 방식 내화풍도슬래브의 화재저항성 평가 (Fire resistance assessment of precast fireproof duct slab)

  • 최순욱;강태호;이철호;김세권;김태균;장수호
    • 한국터널지하공간학회 논문집
    • /
    • 제22권6호
    • /
    • pp.669-680
    • /
    • 2020
  • 국내에서는 중요 구조물을 대상으로 별도의 내화시험을 통해 내화성능을 평가하고 있으며, 그 성능기준으로 ITA에서 제시하고 있는 가이드라인을 따르고 있다. 프리캐스트 방식으로 슬래브와 내화재가 일체화되어 제작되는 내화풍도슬래브는 내화재 시공시간을 단축할 수 있다는 점에서 효과적이다. 본 연구에서는 풍도슬래브의 내화성능을 확보하기 위해 RWS화재시나리오 하에서 내화시험체에 대한 화재저항시험을 수행하였다. 시험결과, 내화재 두께가 30 mm 이상에서 내화성능을 확보하는 것으로 나타났다. 내화재와 콘크리트 모두에서 온도 변화율이 초기에 증가했다가 감소하고 다시 증가하는 경향이 나타났으며, 다시 증가하는 변곡점에서의 온도가 모든 내화재와 콘크리트에서 110℃로 측정되었다. 이것은 내화재와 콘크리트가 모두 수화반응에 의해 생성된 C-S-H (CaO-SiO2-H2O)가 탈수되면서 발생하는 것으로 판단된다.