• 제목/요약/키워드: brushless

검색결과 766건 처리시간 0.026초

Cooling Fan 구동용 300W BLDC motor 설계 및 특성해석에 관한 연구 (A study on the Design and Analysis of 300W BLDC motor for a cooling fan)

  • 안영일;박창순;맹경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.104-106
    • /
    • 2003
  • In recent years for propulsion of cooling fan in cars are more used electrical motors than the engine direct coupled type. But the electrical motor which is now used has the brush and the commutator. Because of the brush and the commutator the electrical motor has short life time, low efficiency and mechanical- electrical noise. Therefore it is tried to develope brushless dc motor. The motor is located in the hot air from the radiator. The motor temperature increases high and the increasing of the motor temperature rolls big in its character. The cooling fan motor has relative small in size and input voltage is low. For 300 w output power must be the current of the motor high which causes high copper loss. In this paper will be tested and analysed characteristics of a dc motor which is now used for cooling fan and a BLDC motor will be designed with same character of the brushed motor and with considering of improvement of the efficiency. After design the motor should be analysed and tested.

  • PDF

미지입력 관측기를 이용한 BLDC 전동기 센서리스 드라이브에 대한 연구 (Sensorless Drive of Brushless DC Motors Using an Unknown Input Observer)

  • 류지수;현동석;김태성
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.65-71
    • /
    • 2006
  • 본 논문에서는 BLDC 전동기 센서리스 드라이브의 성능 향상을 위한 새로운 전동기 제어 기법을 제안한다. 최근 센서리스 제어방법의 주류를 이루고 있는 단자전압을 이용하는 방식들은 전동기를 동기 모드로 운전할 때 과도한 전압이 인가되면, 회전자 위치를 정확하게 검출할 수 없다. 특히 과도상태영역에서의 응답특성이 좋지 않다. 따라서 본 논문에서는 미지 입력인 역기전력을 추가적인 시스템의 상태로 모델링하고, 전체 시스템을 역기전력에 대한 미분방정식 형태 외란 모델을 도입한 확장 상태방정식으로 표현함으로서 얻어지는 상태관측기를 통하여 전동기의 속도 및 회전자 위치를 추정하는 새로운 알고리즘을 제안한다.

허브 형상에 따른 정풍량 환기팬의 유동과 성능특성 (Flow Behavior and Performance Characteristics of Constant Air Volume Fan According to Different Hub Shape)

  • 이호호;최항철;정재구;이윤표;신유환;정진택
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.57-62
    • /
    • 2012
  • The constant air volume flow fan can maintain constant flow rate to the wide range of exit pressure. Therefore, the use of this fan is increasing recently for ventilation of high building. Brushless DC motor is adopted to this fan because that has advantages of compactness and performance. But this type of motor protrude from impeller hub side to fan inlet. The Impeller inlet flow is influenced by size of this obstacle called hub. In this paper, the influence of hub shape on the fan performance characteristics are experimentally and numerically analyzed. CFX 12.0 is used to perform the fan internal flow analysis and numerical results are compared with the experiments. Depending on hub shape, internal loss is generated and the performance and efficiency are reduced. The best performance is occurred around $h/b_1$ = 0.25. The results of this study will be contribute to initial design of constant air volume flow fan development.

BLDC 모터로 구동되는 액체 추진제 로켓엔진용 극저온 추력제어밸브 개발 (Development of BLDC Motor Driven Cryogenic Thrust Control Valve for Liquid Propellant Rocket Engine)

  • 정태규;이수용
    • 한국항공우주학회지
    • /
    • 제38권10호
    • /
    • pp.1026-1030
    • /
    • 2010
  • 본 논문에서는 KSLV-II의 로켓엔진에 사용될 BLDC 모터로 구동되는 극저온 추력제어 밸브의 개발 과정 및 결과를 소개하였다. 개발된 추력제어밸브는 90K의 극저온, 113.2bar의 고압 환경에서 액체산소의 유량을 BLDC 모터로 작동되는 밸브 구동기를 통해 조절할 수 있다. 추력제어밸브는 모든 개발 인증시험을 통과하였으므로 향후 일부 하드웨어 수정 후, 엔진 연소시험에 적용이 가능하다.

단상 외전형 브러시리스 모터의 권선 인덕턴스 (Winding Inductance for Single-Phase Outer Rotor Brushless DC Motor)

  • 주대석;조주희;이상택;신덕식;김창환;우경일;김희준;류재영;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.973-974
    • /
    • 2011
  • 이 논문은 단상 외전형 브러시리스 모터의 권선 인덕턴스를 해석적인 방법으로 산정하고 실험결과와 비교하였다. 모터의 초기 설계단계에서 사용하는 자기회로해석은 매우 유용하고, 인덕턴스는 자기회로해석에서 중요한 파라미터이다. 회전자계의 영향은 쇄교 자속으로 표현할 수 있고 자속 쇄교수는 인덕턴스에 비례하기 때문이다. 따라서 모터의 특성해석을 위해서 인덕턴스 산정은 매우 중요하다. 해석적인 방법으로 권선 인덕턴스를 산정하였고 회전자의 영향을 무시하였다. 그리고 LCR 미터와 전류 변화법으로 각각 권선 인덕턴스를 측정하였다. 해석값과 전류 변화법으로 측정한 권선 인덕턴스는 비슷하였다. 이 논문에서 제시한 권선 인덕턴스의 해석적인 산정방법은 모터의 초기 설계단계에서 자기회로해석으로 특성을 해석하는 데 도움이 될 것이다.

  • PDF

Highly Efficient AC-DC Converter for Small Wind Power Generators

  • Ryu, Hyung-Min
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.188-193
    • /
    • 2011
  • A highly efficient AC-DC converter for small wind power generation systems using a brushless DC generator (BLDCG) is presented in this paper. The market standard AC-DC converter for a BLDCG consists of a three-phase diode rectifier and a boost DC-DC converter, which has an IGBT and a fast recovery diode (FRD). This kind of two-stage solution basically suffers from a large amount of conduction loss and the efficiency greatly decreases under a light load, or at a low current, because of the switching devices with a P-N junction. In order to overcome this low efficiency, especially at a low current, a three-phase bridgcless converter consisting of three upper side FRDs and three lower side Super Junction FETs is presented. In the overall operating speed region, including the cut-in speed, the efficiency of the proposed converter is improved by up to 99%. Such a remarkable result is validated and compared with conventional solutions by calculating the power loss based on I-V curves and the switching loss data of the adopted commercial switches and the current waveforms obtained through PSIM simulations.

소형/고효율 고분자전해질 연료공급모듈용 Air Blower 개발에 관한 연구 (Study on Air Blower for Air Management System)

  • 최준혁;정인성;김주한;서정무;허진;성하경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.212-214
    • /
    • 2006
  • Air Management System is composed by Pump, Fan, Compressor and Blower In general their performances depend on the capability of the motor, power converter device and controller. Especially, it should be noticed upon designing Air Management System using for Fuel Cell System, that Pump, Fan, Compressor and Blower satisfy the condition of the high performance, high efficiency, high density and reasonable price considering the safety and Economic Efficiency. In order for this, it should be studied that which kind of Motor is the most suited for Air Management System for Fuel Cell, such as Induction Motor, Brushless DC Motor, and Switched Reluctance Motor which is widely using in industry. This paper presents the designing and manufacturing of Outer Rotor Type BLDC Motor and Driver for Air Blower of Air Management System. Experimental results from a laboratory prototype arc presented to validate the feasibility of the proposed Air Blower Motor and Driver.

  • PDF

PFC Bridge Converter for Voltage-controlled Adjustable-speed PMBLDCM Drive

  • Singh, Sanjeev;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.215-225
    • /
    • 2011
  • In this paper, a buck DC-DC bridge converter is used as a power factor correction (PFC) converter for feeding a voltage source inverter (VSI) based permanent magnet brushless DC motor (PMBLDCM) drive. The front end of the PFC converter is a diode bridge rectifier (DBR) fed from single phase AC mains. The PMBLDCM is used to drive the compressor of an air conditioner through a three-phase voltage source inverter (VSI) fed from a variable voltage DC link. The speed of the air conditioner is controlled to conserve energy using a new concept of voltage control at a DC link proportional to the desired speed of the PMBLDC motor. Therefore, VSI operates only as an electronic commutator of the PMBLDCM. The current of the PMBLDCM is controlled by setting the reference voltage at the DC link as a ramp. The proposed PMBLDCM drive with voltage control-based PFC converter was designed and modeled. The performance is simulated in Matlab-Simulink environment for an air conditioner compressor load driven through a 3.75 kW, 1500 rpm PMBLDC motor. To validate the effectiveness of the proposed speed control scheme, the evaluation results demonstrate improved efficiency of the complete drive with the PFC feature in a wide range of speed and input AC voltage.

소형 BLDC 전동기 센서리스 드라이브의 단상 역기전력과 중성점을 이용한 제어기법 연구 (A Study on a Control Method for Small BLDC Motor Sensorless Drive with the Single Phase BEMF and the Neutral Point)

  • 조준우;황돈하;황영기;정태욱
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.1-7
    • /
    • 2014
  • Brushless Direct Current(BLDC) Motor is essential to measure a rotor position because of that this motor type needs to synchronize the rotor's position and changeover phase current instead of a brush and commutator used on the existing dc motor. Recently, many researches have studied on sensorless control drive for BLDC motor. The conventional control methods are a compensation value dq, Kalman filter, Fuzzy logic, Neurons neural network, and the like. These methods has difficulties of detecting BEMF accurately at low speed because of low BEMF voltage and switching noise. And also, the operation is long and complex. So, it is required a high-performance microprocessor. Therefore, it is not suitable for a small BLDC motor sensorless drive. This paper presents control methods suitable for economic small BLDC motor sensorless drive which are an improved design of the BEMF detection circuit, simplifying a complex algorithm and computation time reduction. The improved motor sensorless drive is verified stability and validity through being designed, manufactured and analyzed.

플럭스 스위칭 전동기의 고효율 드라이브에 대한 연구 (A Study on High Efficiency Flux Switching Motor drive)

  • 민병재;김동희;구본삼;최경호;김남훈
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.92-100
    • /
    • 2010
  • 최근에는 파워툴(Power tools)과 가전 제품에 있어서 전자적인 전류(commutation)를 사용하는 새로운 형태의 브러시리스 전동기인 플럭스 스위칭 전동기(Hux switching motor)에 대한 관심이 점차적으로 증가되고 있으며, 특히 팬과 펌프 시장에 있어서는 그린 정책으로 인하여 플럭스 스위칭 전동기에 대한 관심이 급격히 증가되고 있다. 플럭스 스위칭 전동기는 유도전동기에 비해서는 높은 전력 밀도(power density)와 상대적으로 높은 효율,그리고 브러시리스 DC 전동기에 비해서는 간단한 전동기 구조와 가격 경쟁력이라는 장점을 가지고 있다. 따라서 본 논문에 서는 팬 용도로 제작된 12/6 폴을 가지는 플럭스 스위칭 전동기의 동작원리와 고효율 드라이브의 타당성을 검증하기 위해서 TMS320F2812 DSP를 이용한 실험 결과를 제시한다.