DOI QR코드

DOI QR Code

Highly Efficient AC-DC Converter for Small Wind Power Generators

  • Ryu, Hyung-Min (Dept. of Electrical Engineering, Dong-Eui University)
  • Received : 2010.09.25
  • Accepted : 2011.01.08
  • Published : 2011.03.20

Abstract

A highly efficient AC-DC converter for small wind power generation systems using a brushless DC generator (BLDCG) is presented in this paper. The market standard AC-DC converter for a BLDCG consists of a three-phase diode rectifier and a boost DC-DC converter, which has an IGBT and a fast recovery diode (FRD). This kind of two-stage solution basically suffers from a large amount of conduction loss and the efficiency greatly decreases under a light load, or at a low current, because of the switching devices with a P-N junction. In order to overcome this low efficiency, especially at a low current, a three-phase bridgcless converter consisting of three upper side FRDs and three lower side Super Junction FETs is presented. In the overall operating speed region, including the cut-in speed, the efficiency of the proposed converter is improved by up to 99%. Such a remarkable result is validated and compared with conventional solutions by calculating the power loss based on I-V curves and the switching loss data of the adopted commercial switches and the current waveforms obtained through PSIM simulations.

Keywords

References

  1. S.-H. Song, S.-I. Kang, and N.-K. Hahm, "Implementation and control of grid connected AC-DC-AC power converter for variable speed wind energy conversion system," IEEE Applied Power Electronics Conference and Exposition, Vol. 1, pp. 154-158, Feb. 2003.
  2. M. Chinchilla, S. Arnaltes, and J. C. Burgos, "Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid," IEEE Trans. Energy Convers., Vol. 21, No. 1, pp. 130-135, Mar. 2006. https://doi.org/10.1109/TEC.2005.853735
  3. M. Valentini, A. Raducu, D. Sera, and R. Teodorescu, "PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation," 11th International Conference of Optimization of Electrical and Electronic Equipment, pp. 433-438, May 2008.
  4. H. Schmidt, S. Christoph, and J. Ketterer, "Current inverter for direct/alternating currents, has direct and alternating connections with an intermediate power store, a bridge circuit, rectifier diodes and an inductive choke," German Patent DE10 221 592 A1, Dec. 2003.
  5. M. Victor, F. Greizer, S. Bremicker, and U. Huebler, "Verfahren zum umwandeln einer elektrischen gleichspannung einer gleichspan-nungsquelle, insbesondere einer photovoltaik-gleichspannungsquelle in eine wechselspannung," German Patent DE102004 030 912 B3, Jan. 2006.
  6. M. Frisch and T. Erno, "Design concept for a transformerless solar inverter," Power Electronics Europe (www.power-mag.com), Issue 1, pp. 28-30, Jan. 2010.
  7. S. Shimizu, M. Uesugi, T. Toshi, T. Endo, and H. Mochikawa, "Application and development of high efficient inverter system for air conditioner," Domestic conference of the Institute of Electrical Engineers of Japan, Industry Application, I-113, 2006.
  8. A. Miller, E. Muljadi, and D. S. Zinger, "A variable speed wind turbine power control," IEEE Trans. Energy Convers., Vol. 12, No.2, pp. 181-186, Jun. 1997. https://doi.org/10.1109/60.629701
  9. D. M. Mitchell, "AC-DC converter having an improved power factor," U.S. Patent 4 412 277, Oct. 25, 1983.
  10. B. Lu, R. Brown, and M. Soldano, "Bridgeless PFC implementation using one cycle control technique," IEEE Applied Power Electronics Conference and Exposition, Vol. 2, pp. 812-817, Mar. 2005.
  11. L. Huber, Y. Jang, and M. M. Jovanovic, "Performance evaluation of bridgeless PFC boost rectifiers," IEEE Trans. Power Eletron., Vol. 23, No. 3, May 2008.

Cited by

  1. Analysis and Implementation of a DC-DC Converter for Hybrid Power Supplies Systems vol.15, pp.6, 2015, https://doi.org/10.6113/JPE.2015.15.6.1438
  2. Highly Efficient High-Voltage MOSFET Converter with Bidirectional Power Flow Legs vol.14, pp.2, 2014, https://doi.org/10.6113/JPE.2014.14.2.265