• 제목/요약/키워드: brick masonry

검색결과 98건 처리시간 0.023초

중량벽체의 차음특성에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Characteristics of Heavyweight Walls)

  • 김선우;이태강;송민정
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1078-1085
    • /
    • 1998
  • This study is carried out to investigate the characteristics of sound insulation performances for masonry walls. PC walls and ALC walls. For these purposes. 17 types of masonry walls were selected and tested in accordance with KS F 2808 at reverberation room The sound insulation performance of 8" cement block walls are graded with D-45 ∼ D-55 which are to be evaluated very favorable grade. 4" cement block walls are D-30 ∼ D-40. 1 B cement brick walls are D-40∼D-50 favorable grade. 0.5 B brick walls are D-30∼D-45. 150 mm PC wall is D-50. and ALC walls(150 mm, 200 mm) are D-30∼D-45.

  • PDF

A methodology for development of seismic fragility curves for URBM buildings

  • Balasubramanian, S.R.;Balaji, Rao K.;Meher, Prasad A.;Rupen, Goswami;Anoop, M.B.
    • Earthquakes and Structures
    • /
    • 제6권6호
    • /
    • pp.611-625
    • /
    • 2014
  • This paper presents a simple methodology that integrates an improved storey shear modelling, Incremental Dynamic Analysis and Monte Carlo Simulation in order to carryout vulnerability analysis towards development of fragility curves for Unreinforced Brick Masonry buildings. The methodology is demonstrated by developing fragility curves of a single storey Unreinforced Brick Masonry building for which results of experiment under lateral load is available in the literature. In the study presented, both uncertainties in mechanical properties of masonry and uncertainties in the characteristics of earthquake ground motion are included. The research significance of the methodology proposed is that, it accommodates a new method of damage grade classification which is based on 'structural performance characteristics' instead of 'fixed limiting values'. The usefulness of such definition is discussed as against the existing practice.

Field investigation and seismic analysis of a historical brick masonry minaret damaged during the Van Earthquakes in 2011

  • Muvafik, Murat
    • Earthquakes and Structures
    • /
    • 제6권5호
    • /
    • pp.457-472
    • /
    • 2014
  • The paper presents the field investigations and seismic analyses of a historical masonry brick minaret damaged during October 23 (Erciş) and November 9 (Edremit), 2011 Van earthquakes in Turkey. Ulu Mosque Minaret located on Tebriz Kap1 Street in the city centre of Van, Turkey is selected for investigation. Two earthquakes hit the minaret within seventeen days, causing progressive damage. It was seen from the field investigations that the minaret was heavily damaged. To validate the field investigations, three dimensional finite element model of the minaret is constituted by ANSYS software using relievo drawings. Finite element model of the minaret is analyzed under the Van earthquake records to determine the seismic behavior. The displacements, maximum and minimum principal stresses and strains are obtained from the analyses and compared with field observations.

Collapse behaviour of three-dimensional brick-block systems using non-linear programming

  • Baggio, Carlo;Trovalusci, Patrizia
    • Structural Engineering and Mechanics
    • /
    • 제10권2호
    • /
    • pp.181-195
    • /
    • 2000
  • A two-step procedure for the application of non linear constrained programming to the limit analysis of rigid brick-block systems with no-tension and frictional interface is implemented and applied to various masonry structures. In the first step, a linear problem of programming, obtained by applying the upper bound theorem of limit analysis to systems of blocks interacting through no-tension and dilatant interfaces, is solved. The solution of this linear program is then employed as initial guess for a non linear and non convex problem of programming, obtained applying both the 'mechanism' and the 'equilibrium' approaches to the same block system with no-tension and frictional interfaces. The optimiser used is based on the sequential quadratic programming. The gradients of the constraints required are provided directly in symbolic form. In this way the program easily converges to the optimal solution even for systems with many degrees of freedom. Various numerical analyses showed that the procedure allows a reliable investigation of the ultimate behaviour of jointed structures, such as stone masonry structures, under statical load conditions.

근대기 대구지역 벽돌조 강당 건물의 건축특성과 파사드 구성에 관한 연구 - 남산초등학교 강당을 중심으로 - (A Study on the Architectural Characteristics and Facade Construction of the Brick Masonry Auditorium in Daegu During the Modern Age - Focused on the Auditorium of Namsan Primary School -)

  • 윤재웅
    • 건축역사연구
    • /
    • 제19권6호
    • /
    • pp.121-135
    • /
    • 2010
  • This study was to analyze the architectural characteristics and facade construction of brick masonry auditorium through the Auditorium of Namsan Primary School in 1936. The results of this study were described separately as follows. 1. The auditorium is located away from the school buildings, and its plane is a chamber of rectangle type with an entrance installed on each of the four sides. 2. The external appearance is Renaissance eclectic style, laid red bricks on the lower wall of the window and having a mansard roof. The front and the rear are symmetric with respect to the projected wall at the center. 3. As to the structure of the building, a concrete lower wall was built on the concrete continuous footing, and the brick wall was constructed on the lower wall. The roof is queen post roof truss, and the wall girders were installed on the brick wall. 4. The auditorium has had a number of repairing and maintenance works, which changed the roof and windows outside and the floor, walls, ceiling, etc. inside. 5. The decorative elements of external appearance include lower wall, brick wall, entrances, windows, roof, and dormer windows. The brick wall gives verticality and solidity to the surface of the wall, and the lower wall and wall girders are connected like a cornice of the wall. The surface of the mansard roof and dormer windows express a stable vertically oriented shape.

비보강 시멘트벽돌 건물의 내진성능 실험연구 (Experimental Study on Seismic Resistance of A Unreinforced Cement Brick Building)

  • 김장훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.298-307
    • /
    • 2000
  • The behavior of a unreinforced cement brick building structure subjected to earthquake loading was experimentally investigated. for this four full size wall specimens were tested under quasi-static in-plane cyclic loading. Experimental observations indicate that the failure modes of unreinforced masonry walls are principally governed by sliding or/and rocking depending on the aspect ration and magnitude of axial loading. Also found was the flexure or shear mode resulting from the degraded strength of brick and/or mortar due to the cyclic loading effect.

  • PDF

조적조의 물리적 특성에 관한 실험적 연구 (An Experimental Study on the Physical Property of the Masonry)

  • 유혜란;권기혁
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.497-500
    • /
    • 2006
  • Masonry buildings constructed using concrete brick and cement mortar after normal Poteulranteu cement appearance, but problem of colloquial Chinese and individual crack etc. happened. Also, domestic standard abroad standard being applied mostly just as it is various kinds problem have. Therefore, purpose of this research is that wish to analyze physical special quality for Masonry individual and mortar and present pabulum that can evaluate deviation structural special quality.

  • PDF

Vulnerability curves of masonry constructions Algiers case study

  • Djaalali, F.;Bensaibi, M.;Bourahla, N.;Davenne, L.
    • Structural Engineering and Mechanics
    • /
    • 제42권5호
    • /
    • pp.609-629
    • /
    • 2012
  • This study deals with the assessment of low and mid rise multi-story buildings made of stone and /or brick, composite steel and masonry slabs from the sixties, known to be vulnerable to seismic hazard using the "vulnerability index" method based on buildings survey following Ain Temouchent (1999) and Boumerdes (2003) earthquakes, from where vulnerability curves are constructed using the translation method. The results obtained for the case study confirm what has been observed in situ.

점토벽돌과 석회모르타르를 사용한 조적구조의 역학적 특성에 관한 연구 (A Study on Mechanical Characteristics of Masonry Structure Constructed by Clay Brick with Lime Mortar)

  • 유혜란;권기혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.87-98
    • /
    • 2011
  • 최근 생태 친환경 건축이 화두로 등장하면서 친환경 건축재료인 점토벽돌과 공기의 흐름과 수분의 이동이 가능한 석회모르타르의 사용이 증가하고 있다. 하지만 국내 연구는 콘크리트벽돌과 시멘트모르타르에 집중되고 있어 점토벽돌 및 석회모르타르에 대한 연구가 거의 없는 실정이며, 조적조의 국내 기준 또한 국내에서 사용되는 재료와 다른 물리적 값을 사용하고 있는 국외기준을 바탕으로 제정되어 국내 실정을 적절히 반영하지 못하고 있다. 따라서 본 연구는 프리즘압축강도, 부착강도, 전단 및 사인 장강도 실험을 통해 점토벽돌과 석회모르타르를 사용한 조적구조의 물리적 특성을 파악하고자 한다. 또한, 콘크리트벽돌과 시멘트모르타르를 사용한 조적구조와의 물리적 특성을 비교분석하여 국내 조적기준을 개정하기 위한 근거를 제시하고자 한다. 점토 벽돌과 석회모르타르를 적용한 조적구조는 콘크리트벽돌과 시멘트모르타르를 사용한 조적구조와는 다른 양상을 보이므로 점토벽돌과 석회모르타르를 적용한 조적구조의 프리즘압축강도와 탄성계수에 대한 추정식을 제안한다.

Full-scale experimental evaluation of a panelized brick veneer wall system under simulated wind loading

  • Liang, Jianhai;Memari, Ali M.
    • Structural Engineering and Mechanics
    • /
    • 제38권1호
    • /
    • pp.99-123
    • /
    • 2011
  • Brick veneer over steel stud backup wall is lighter and easier to construct compared to brick veneer over concrete masonry backup wall. However, due to the relatively low stiffness of the steel stud backup, the brick veneer tends to crack under wind load. This paper briefly introduces a new panelized brick veneer with steel frame backup wall system that is developed to potentially address this problem. The experimental study of the performance of this system under simulated wind loading is discussed in detail. The test setup details and the test specimens are introduced, results of major interests are presented, and performance of the new system is evaluated based on the test results.