• 제목/요약/키워드: breakdown point

검색결과 168건 처리시간 0.034초

저항률에 따른 수중방전 특성에 관한 연구 (A Study of underwater discharge characteristics in different resistivity)

  • 이복희;최종혁;이강수;;;안창환;정용기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.254-255
    • /
    • 2007
  • This paper describes underwater discharge phenomena which are less studied than gas, solid and dielectric liquid. Since discharge phenomena were affected by various factors, we investigated the effect of water resistivity in point-plane gap by impulse voltage. In discharge photograph, it is hard to discover the streamer development in positive polarity at high reisistivity. On the other hand, the streamer originated at the tip of rod and developed toward the plane with increasing voltage. It is found that the breakdown voltage of both polarities in lower resistivity are lower than that of high resistivity. High current flowing in lower resistivity before the breakdown induce more streamer and enhance the probability of breakdown.

  • PDF

불평등 전계에서 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스의 절연 내력 (Dielectric Strength of $SF_6/CF_4$ Mixture Under Standard Lightning Impulse Voltages in Non-Uniform Field)

  • 허창수;성허경;박신우;황청호;김남렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.165-166
    • /
    • 2007
  • In these days $SF_6$ mixtures and alternative gas have been studied because of global warming and liquefying at low temperature and high pressure. At present work the breakdown characteristics of $SF_6/CF_4$ mixture in non-uniform field was performed. The experiments were carried out under positive and negative standard lightning impulse (SLT) voltages. The point-plane electrode was used with 3 mm gap distance in the test chamber. The $SF_6/CF_4$ mixture which contain 20% of $SF_6$ was compared with pure $SF_6$ and $CF_4$ gas. Experimental gas pressure ranged from 0.1 to 0.4 MPa. The breakdown voltage under negative SLI is higher than the breakdown voltage under positive voltage. And the breakdown voltage of $SF_6$ 20%, $CF_4$ 80% mixture is similar to that of pure $SF_6$.

  • PDF

침대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 원통형 3전극의 영향 (Effect of a Cylindrical Third Electrode of a Point-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 문재덕;정호준;정재승
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.933-937
    • /
    • 2007
  • A point plate type nonthermal plasma reactor, with a grounded cylindrical third electrode which closely- encompasses the needle point, have been investigated with an emphasis on the role of the third electrode. It was found that the point plate airgap, with the grounded third electrode, had a switching characteristic on its I V characteristics for negative and positive discharges, which is very different from that of a conventional point plate airgap without a third electrode. The corona discharge and ozone generation characteristics of the plasma reactor with the grounded cylindrical third electrode, such as the corona onset voltage. the breakdown voltage. the corona current. and the amount of output ozone, were influenced significantly by the height of the third electrode. and these characteristics can be controlled by adjusting the height of the third electrode.

고속도로의 용량산정 방법론 개발에 관한 연구 (Development of New Freeway Capacity Estimation Method)

  • 김영선;이상수
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.123-133
    • /
    • 2015
  • PURPOSES : This study aimed to develop a new highway capacity estimation method and provide comparative results among traditional capacity estimation methods and the recommended values in the latest version of KHCM. METHODS : The limitations of the existing methods, such as inconsistency and underestimation of the capacity value, are summarized through an extensive literature review. To overcome these limitations, a new method is introduced by adopting a definition of capacity and traffic flow characteristics at or near breakdown points. This method can produce the capacity value by searching a point corresponding to the maximum traffic flow through analysis of gradient changes (point of inflection) of the traffic flow and speed distribution. Comparative results of capacity values from each method are also presented to validate the new method by using data collected from detectors on freeways. RESULTS: From the analysis results, it is shown that a consistent capacity value can be estimated by applying the new method. In addition, the resulting capacity values are 3%-4% higher than those recommended in KHCM. CONCLUSIONS : The capacity values listed in the current KHCM tend to produce underestimated results. The new method presented in this paper may be included in the future edition of KHCM.

72.5 kV 풍력 발전용 Dry-air Switchgear의 절연 특성 (Insulation Characteristics of Dry-air Insulated Switchgear for 72.5 kV Wind Power Generation)

  • 양찬희;오진석;박희태;김영일
    • 풍력에너지저널
    • /
    • 제15권2호
    • /
    • pp.5-9
    • /
    • 2024
  • This paper describes the insulation breakdown characteristics of 72.5 kV dry-air insulated switchgear under development for installation in a wind power generator when a lightning impulse voltage is applied. For this study, the weak point of insulation due to the electric field concentration of the switchgear's internal shape was identified by finite element method (FEM) analysis, and the shape was actually simulated to measure and analyze the polarity of the lightning impulse voltage and the insulation breakdown characteristics according to the gas pressure at dry-air pressures of 0.1 Mpa to 0.45 Mpa. This study derives the maximum electric field with a 50 % discharge probability for each switchgear internal insulation vulnerable point based on the actual test and electrical simulation, which will be useful as reference data for supplementing and changing insulation design in the future.

Improvement of Interfacial Performances on Insulating and Semi-conducting Silicone Polymer Joint by Plasma-treatment

  • Lee, Ki-Taek;Huh, Chang-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권1호
    • /
    • pp.16-20
    • /
    • 2006
  • In this paper, we investigated the effects of short-term oxygen plasma treatment of semiconducting silicone layer to improve interfacial performances in joints prepared with a insulating silicone materials. Surface characterizations were assessed using contact angle measurement and x-ray photoelectron spectroscopy (XPS), and then adhesion level and electrical performance were evaluated through T-peel tests and electrical breakdown voltage tests of treated semi-conductive and insulating joints. Plasma exposure mainly increased the polar component of surface energy from $0.21\;dyne/cm^2$ to $47\;dyne/cm^2$ with increasing plasma treatment time and then leveled off. Based on XPS analysis, the surface modification can be mainly ascribed to the creation of chemically active functional groups such as C-O, C=O and COH on semi-conductive silicone surface. This oxidized rubber layer is inorganic silica-like structure of Si bound with three to four oxygen atoms ($SiO_x,\;x=3{\sim}4$). The oxygen plasma treatment produces an increase in joint strength that is maximum for 10 min treatment. However, due to brittle property of this oxidized layer, the highly oxidized layer from too much extended treatment could be act as a weak point, decreasing the adhesion strength. In addition, electrical breakdown level of joints with adequate plasma treatment was increased by about $10\;\%$ with model samples of joints prepared with a semi-conducting/ insulating silicone polymer after applied to interface.

전력용 피뢰기의 열안정화 특성 (Study on Thermal Stability Characteristics of Surge Arrester for High Power)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1142-1145
    • /
    • 2004
  • ZnO surge arresters continuously endure the operating voltages during the operation course, and in the mean time, which need to withstand occasionally transient voltages of lightning and switching overvoltages. Under these voltages, the ZnO varistors inside arresters would have aging phenomena, one important result of aging phenomena is the increasing of resistive currents of varistors, which leads to the increasing of power losses of varistors. And the operating voltage is continuously applied on the ZnO varistors, there is a degradation phenomenon existing in ZnO varistors. When the degradation reaches a certain degree, then the arrester must stop operation. The degradation is related to the applied voltage ratio, the applied voltage ratio is high, the degradation is quickly. When the power loss is higher than the thermal dispersion ability of house of arrester, then the arrester will thermally breakdown. In this study the thermal stability characteristics of surge arresters for high power wil be discussed on the view point of watt losses and thermal breakdown.

  • PDF

지중송전 편단접지개소에서의 병행지선 설치효과 검토 (Study on the Effect of Parallel Ground Conductor at the Single Point Bonding in Underground Transmission System)

  • 강지원;박흥석;윤형희;윤종건;배주호;석광현;오장만;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.736-737
    • /
    • 2007
  • The single point bonding in underground transmission system can induce high voltage on the sheath when ground fault, lightning serge and switching serge occurs, at that time underground cable systems cannot offer a return path of fault current. Accordingly if fault current, which cannot return to ground, flows at the single point bonding, high voltage can be induced in SVL and that voltage can cause aging and breakdown of SVL. Therefore this paper study on the effect of parallel ground conductor at the single point bonding when ground fault and lightning serge occurs by using ATPDraw.

  • PDF

가로등 회로 손상 선별 장치 개발 (Development of Selecting Equipment for Damage of Street Lamp Circuit)

  • 조현섭
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2294-2297
    • /
    • 2011
  • 본 연구는 현재 사용되고 있는 가로등 회로의 손상을 선택적으로 점검하기 위한 다이오드를 개발하였다. 개발된 가로등 진단기는 LED 표시 체계의 점등 유무를 파악하여 선택적으로 점검할 수 있으며, 가로등이 점등되지 않을 경우 어느 부분에 고장이 발생했는지 LED 소등의 관계로 표시 할 수 있다. 회로는 PCB 기판을 제작하여 가로등 개별단의 고장점 위치를 확인할 수 있는 시스템을 개발하였다.

FMEA에 의한 기계 부품의 신뢰도 분석

  • 이상진;고장주;강창학;이치우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.87-91
    • /
    • 2004
  • This paper dealt with FMEA, Which is a method of the analysis to secure safety and confidence coming up to customer's expectation in consideration of the environment of the corporation, the industrial environment, and the functional improvement. And by using FMEA, We showed the example analyzed the confidence of the reduction gear. It was proved by the result of the analysis that the rate of the breakdown which is usually regarded as the first important point to reform can't satisfy the selecting basis to improve. Also the result said that it is not right to depend on only the rate of the failure in making the list of the reform. Through the analysis of the breakdown, FMEA can present the important factors of the reform to improve the confidence of the system. In this study would show the important factors of the improvement in order to product the goods guaranteed confidence through the method of FMEA.

  • PDF