• 제목/요약/키워드: branch-line

Search Result 391, Processing Time 0.027 seconds

A Framework for Wide-area Monitoring of Tree-related High Impedance Faults in Medium-voltage Networks

  • Bahador, Nooshin;Matinfar, Hamid Reza;Namdari, Farhad
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Wide-area monitoring of tree-related high impedance fault (THIF) efficiently contributes to increase reliability of large-scaled network, since the failure to early location of them may results in critical lines tripping and consequently large blackouts. In the first place, this wide-area monitoring of THIF requires managing the placement of sensors across large power grid network according to THIF detection objective. For this purpose, current paper presents a framework in which sensors are distributed according to a predetermined risk map. The proposed risk map determines the possibility of THIF occurrence on every branch in a power network, based on electrical conductivity of trees and their positions to power lines which extracted from spectral data. The obtained possibility value can be considered as a weight coefficient assigned to each branch in sensor placement problem. The next step after sensors deployment is to on-line monitor based on moving data window. In this on-line process, the received data window is evaluated for obtaining a correlation between low frequency and high frequency components of signal. If obtained correlation follows a specified pattern, received signal is considered as a THIF. Thereafter, if several faulted section candidates are found by deployed sensors, the most likely location is chosen from the list of candidates based on predetermined THIF risk map.

A New Dual Band Branch Line Hybrid Coupler with Arbitrary Power Division Ratio (임의의 분배비를 갖는 새로운 이중 대역 가지 선로 결합기)

  • Kim, Kwi-Soo;Gwon, Chil-Hyeun;Dorjsuren, Baatarkhuu;Lim, Jong-Sik;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.5
    • /
    • pp.444-449
    • /
    • 2009
  • This paper presents the design of a dual band branch line hybrid coupler(BLHC) with different power division ratios at two bands. In the proposed design, transmission lines of the BLHC are transformed to $\pi$-type equivalent circuits which represent different impedances and $\lambda/4$ electrical length at two frequency bands. In order to verify the proposed method, a dual band coupler with different power division ratios is designed for 0.9 GHz and 2 GHz applications. The desired power division ratios are 1:1 and 1:3 at the two operating frequency bands. The measured results show excellent performance with an insertion loss of less than 0.33 dB, a return loss of less than -18.07 dB, and good isolation characteristics.

Discharge Variation of Perforated Hoses and Drip Irrigation Systems for Protected Cultivation (시설재배용 분수호스 및 점적관수 시스템의 관수균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.297-302
    • /
    • 2007
  • Discharge variations of perforated hose and drip irrigation systems were examined to evaluate irrigation uniformity at different pressures and length of branch line. Evaluation using statistical uniformity indicated that button drippers performed at excellent level but drip tapes and drip hoses were a little lower level. Nominal discharge of drip irrigation systems showed at the high side within the range of regulating pressure provided by the manufacturer. It is desirable that the length of branch line for drip hose, drip tape, and button dripper should be limited to 50 m, 70 m, and 100 m, respectively. Irrigation uniformity of perforated hoses showed very low level. So it is recommended that the length of branch line for perforated hoses should be limited to $30{\sim}35m$.

A study on the thermal deformation characteristics of steel plates due to multi-line heating

  • Lee, Joo-Sung;Lee, Sang-Hoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.48-59
    • /
    • 2018
  • This paper is mainly concerned with developing the formulae of predicting thermal deformation of steel plate due to multi-line heating. By investigating the results of line heating test and numerical analysis, reasonable heat flux model has been defined. Formulae of predicting the transverse shrinkage and the angular distortion as the dominant thermal deformation types in plate forming by line heating have been derived based on the results of line heating test and numerical analysis with varying plate thickness, heating speed and distance between torches. This paper illustrates how the derived formulae are used in investigating the effect of multi-line heating upon the thermal deformation and how they can be used in defining the limit distance with that there is no interacted effect between torches. This paper ends with describing the extension of the present study.

METALLICITY OF GLOBULAR CLUSTER M13 FROM VI CCD PHOTOMETRY

  • Sohn, Young-Jong
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2000
  • From the VI images of M13, obtained by using 2K CCD camera and the BOAO 1.8m telescope, we derive the(V - I) - V CMD of M13. From the shapes of red giant branch, the magnitude of horizontal branch, and the giant branch bump on the constructed CMD, we determined the metallicity of the globular cluster to be 1.74${\lesssim}$[Fe/H]${\lesssim}$-1.41. The good agreement between our determination of [Fe/H] and those determined by using other methods implies that the morphology of red giant and horizontal branches on (V - I) - V CMD's can be good indirect metallicity indicators of Galactic globular clusters.

  • PDF

Branch Loop Antenna for the Mobile Handset (휴대 단말기용 브랜치 루프안테나)

  • Son, Taeho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.58-65
    • /
    • 2013
  • It's introduced a BLA(Branch Loop Antenna) that is modified from conventional loop, and verified antenna performances for applying to mobile handset. Branch elements are added to a rectangular loop, and low resonance is obtained by the length of the branch line. When resonance frequency of a single loop is 2.5GHz, BLA had near 900 MHz under the same antenna size. Multiple resonances are established by the locations of branch connection and their lengths. By the implementation and measurement for the dual band BLA, it's showed 75MHz -10dB bandwidth and -3.03~-1.46dBi average gains with 49.73~71.39% efficiencies at GSM900 band, and 90MHz -6dB bandwidth and -8.14~-2.17dBi average gains with 15.34~60.62% efficiencies at DCS1900 band. And H-plane radiation patterns were omni-directional. These performances are good for the mobile handset antenna.

Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables (혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석)

  • Kim, Byong-Sook;Lee, Jang-Geun;Han, Byoung-Sung;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

A novel method to specify pattern recognition of actuators for stress reduction based on Particle swarm optimization method

  • Fesharaki, Javad Jafari;Golabi, Sa'id
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.725-742
    • /
    • 2016
  • This paper is focused on stiffness ratio effect and a new method to specify the best pattern of piezoelectric patches placement around a hole in a plate under tension to reduce the stress concentration factor. To investigate the stiffness ratio effect, some different values greater and less than unity are considered. Then a python code is developed by using particle swarm optimization algorithm to specify the best locations of piezoelectric actuators around the hole for each stiffness ratio. The results show that, there is a line called "reference line" for each plate with a hole under tension, which can guide the location of actuator patches in plate to have the maximum stress concentration reduction. The reference line also specifies that actuators should be located horizontally or vertically. This reference line is located at an angle of about 65 degrees from the stress line in plate. Finally two experimental tests for two different locations of the patches with various voltages are carried out for validation of the results.

A Study on Automatic Separating System of the Sea Eel Pots from Main Line (통발 자동 분리기에 관한 연구)

  • Jung, Yong-Gil;Park, Young-Gil;Yoo, Keum-Bum
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.139-143
    • /
    • 1998
  • In the fishing process on the sea eel pots, the most dangerous and difficult labor is manually separating process of several thousand pots from main line with high speed hauling operation. In this study, the automatic separating system of the pot from main line is developed. This system is composed with the clip connected to the pot by branch line, the keeper attached to the main line by pressing and the separator separating the clip and the keeper. In the experiment, static and dynamic characteristics of the system are investigated. From the considerations on the experimental results, it is ascertained that the automatic separating system of the pot from main line proposed in this study has good operating performance.

  • PDF

Implementation of a 35KVA Converter Base on the 3-Phase 4-Wire STATCOMs for Medium Voltage Unbalanced Systems

  • Karimi, Mohammad Hadi;Zamani, Hassan;Kanzi, Khalil;Farahani, Qasem Vasheghani
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.877-883
    • /
    • 2013
  • This paper discussed a transformer-less shunt static synchronous compensator (STATCOM) with consideration of the following aspects: fast compensation of the reactive power, harmonic cancelation and reducing the unbalancing of the 3-phase source side currents. The STATCOM control algorithm is based on the theory of instantaneous reactive power (P-Q theory). A self charging technique is proposed to regulate the dc capacitor voltage at a desired level with the use of a PI controller. In order to regulate the DC link voltage, an off-line Genetic Algorithm (GA) is used to tune the coefficients of the PI controller. This algorithm arranged these coefficients while considering the importance of three factors in the DC link voltage response: overshoot, settling time and rising time. For this investigation, the entire system including the STATCOM, network, harmonics and unbalancing load are simulated in MATLAB/SIMULINK. After that, a 35KVA STATCOM laboratory setup test including two parallel converter modules is designed and the control algorithm is executed on a TMS320F2812 controller platform.