• 제목/요약/키워드: bond shear strength

검색결과 861건 처리시간 0.029초

Modelling of shear deformation and bond slip in reinforced concrete joints

  • Biddah, Ashraf;Ghobarah, A.
    • Structural Engineering and Mechanics
    • /
    • 제7권4호
    • /
    • pp.413-432
    • /
    • 1999
  • A macro-element model is developed to account for shear deformation and bond slip of reinforcement bars in the beam-column joint region of reinforced concrete structures. The joint region is idealized by two springs in series, one representing shear deformation and the other representing bond slip. The softened truss model theory is adopted to establish the shear force-shear deformation relationship and to determine the shear capacity of the joint. A detailed model for the bond slip of the reinforcing bars at the beam-column interface is presented. The proposed macro-element model of the joint is validated using available experimental data on beam-column connections representing exterior joints in ductile and nonductile frames.

상아질 표면상태에 따른 광중합형 글래스아이오노머 시멘트의 전단결합강도에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT CURED GLASS IONOMER CEMENTS TO CONTAMINATED DENTIN)

  • 김경화;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.609-621
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three light-cured glass ionomer cements to blood contaminated bovine dentin. The materials used in this study were Fuji II LC, Dyract and Variglass VLC. The dentin conditioners were 10% polyacrylic acid, 10% maleic acid and 10% phosphoric acid. 180 lower anterior bovine teeth were selected in this study. The teeth were embedded in acrylic resin and were grounded with 320 to 600 grit silicon carbide paper to create a flat dentin surface. The teeth were divided into SIX groups. The experimental procedures in six groups were as follows; Group l(GF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment. Group 2(BGF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment and blood contamination. Group 3(MD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment. Group 4(BMD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment and blood contamination. Group 5(PV) : Samples bonded to dentin surface with Variglass VLC after 10% phosphoric acid treatment. Group 6(BPV) : Samples bonded-to dentin surface with Variglass VLC after 10% phosphoric acid treatment and blood contamination. Group 1,3 and 5 were classified into the control groups, while group 2,4 and 6 were classified into the experimental groups. Each group contained 30 samples. After 24 hours water storage at $37^{\circ}C$, all smples were subjected to a shear load to fracture at a cross head speed of 1.0 mm/min with Instron universal testing machine(No. 4467). Debonded surfaces were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically at the 95% confidence level with Student's t-test. The following results obtained; 1. Shear bond strengths were higher in the control groups(1,3,5 group) than in the experimental groups(2,4,6 group). 2. The shear bond strength of group 5(PV) was the highest in the control groups, and the group 5 was significantly higher than the group l(GF) on the shear bond strength. 3. The group 4(BMD) was the highest on the shear bond strength, and the group 2(BGF) was the lowest in the experimental groups. The group 4(BMD) and 6(BPV) showed a significant difference with the group 2 on the shear bond strength. 4. All the groups showed an adhesive-cohesive failure. except the group 2(BGF) showing adhesive failure.

  • PDF

Moisture Insensitive Primer와 Self-Etching Primer를 사용한 교정용 브라켓 접착 시 타액오염이 전단결합강도에 미치는 영향 비교 (Effects of Saliva Contamination on Shear Bond Strength with Conventional, Moisture Insensitive, and Self-Etching Primers)

  • 오윤정;오소희
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.21-28
    • /
    • 2019
  • 이 연구의 목적은 브라켓 부착 시 Conventional primer (CP), Moisture insensitive primer (MIP), Self-etching primer (SEP)을 사용하였을 때의 전단결합강도를 비교하고, 타액 오염 여부와 타액 오염의 시기가 전단결합강도에 미치는 영향을 평가하는 것이다. 총 135개의 소의 하악 절치가 연구에 사용되었다. 시편은 I, II, III 3개의 군으로 나누어 CP, MIP, SEP를 사용하여 브라켓을 부착하였다. 각 군은 3개의 하위군으로 나누어져서 타액 오염이 없는 군, 타액 오염 후 프라이머를 도포한 군, 프라이머 도포 후 타액 오염이 있는 군으로 설정하고 전단결합강도를 측정하였다. 연구 결과, 건조한 환경에서 전단결합강도는 CP, MIP, SEP의 순서로 높게 나타났다. CP는 타액 오염이 있는 경우에는 유의한 전단결합강도의 저하를 보였다. MIP, SEP를 사용한 경우에는 프라이머 도포 전 후 타액 오염이 있는 경우에 약간의 전단결합강도의 저하를 보였지만, 건조한 환경에서와 비교하여 유의한 차이는 보이지 않았다. 따라서 브라켓 접착 시 타액의 격리가 힘든 상황에서는 MIP 또는 SEP의 사용이 브라켓 전단결합강도의 저하를 방지하기 위하여 유용할 것으로 보인다.

광중합형 글래스 아이오노머 시멘트 교정용 브라켓의 전단결합강도에 미치는 영향 (THE EFFECT OF LIGHT CURED GLASS IONOMER CEMENT ON THE SHEAR BOND STRENGTH OF ORTHODONTIC BRACKETS)

  • 김철;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제27권2호
    • /
    • pp.327-334
    • /
    • 1997
  • 광중합형 글래스 아이오노머 시멘트(Fuji Ortho $LS^{(R)}$)와 화학중합형 레진 시멘트(Mono $Lok2^{(R)}$)을 선택하여 사람의 소구치를 대상으로 법랑질을 퍼미스 및 10% 폴리아크릴산, 38%인산으로 표면처리한 후 금속 및 프라스틱 브라켓을 부착하고 섭씨 $37^{\circ}C$의 생리 식염수에 24시간, 48시간 경과 시키고 만능강도시험기를 이용하여 전단결합강도를 측정하고 비교함으로써 교정용 접착제로서 광중합형 글래스 아이오노머 시멘트가 임상적 적용 가능성이 있는지 여부를 규명하고자 시행하여 다음과 같은 결론을 얻었다. 1. 퍼미스로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군의 전단결합강도는 화학중합형 레진군의 결합 강도보다 유의성 있게 낮았다(P<0.01). 2. 10% 폴리아크릴산으로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군의 전단 결합강도는 화학중합형 레진군보다 유의성이 낮았다(PC0.01). 3. 10% 폴리아크릴산으로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군의 전단결합강도는 피미스로 법랑질을 표면처리한 광중합형 글래스 아이오노머 시멘트군보다 약간 높았으나 통계적으로 유의성이 없었다(P<0.05). 4. 메탈과 플라스틱군의 법랑질 표면처리에 관계없이 통계적으로 유의성이 없었다(P<0.05). 이상의 결과를 종합해볼 때 비록 광중합형 글래스 아이오노머 시멘트가 화학중합형 레진 시멘트보다 결합강도는 낮지만 이의 임상적 적용은 가능할 것으로 사료된다.

  • PDF

시효된 복합레진 표면에 다양한 표면 처리 후 부착한 교정용 브라켓의 전단응력 (Effect of Various Surface Treatment Methods on Shear Bond Strength of Orthodontic Brackets to Aged Composite Resin)

  • 박종철;박호원;이주현;서현우
    • 대한소아치과학회지
    • /
    • 제41권2호
    • /
    • pp.125-133
    • /
    • 2014
  • 이 연구의 목적은 시효된 복합레진 수복물에 이산화탄소 레이저로 표면처리한 경우와 기존의 여러 가지 표면처리 방법에 따른 교정용 브라켓의 전단응력을 측정하여 비교하기 위함이다. 복합레진을 이용하여 직경 6 mm, 두께 5 mm의 시편을 96개 제작하였다. 제작된 시편을 인공타액에 침적시켜 $37^{\circ}C$의 온도로 2주 동안 시효처리 하였다. 그 후 96개의 시편을 무작위적으로 16개씩 6개의 군으로 나누었다. 1군은 표면처리를 하지 않았고, 2군은 37% 인산으로, 3군은 4% 불산으로, 4군은 입자 분사 연마로, 5군은 고속 다이아몬드 버로, 6군은 이산화탄소 레이저로 표면처리하였다. 만능 시험기를 이용하여 전단응력을 측정하였으며, 주사전자 현미경을 이용하여 표면처리 양상을 관찰하였다. 버를 사용한 5군이 가장 큰 전단응력 값을 보였으며, 이산화탄소 레이저를 사용한 6군이 그다음으로 큰 값을 보였다. 버를 사용한 5군과 이산화탄소 레이저를 사용한 6군은 나머지 표면처리 방법들보다 통계적으로 유의하게 높은 전단응력 값을 보여주었다(p < 0.05). 또한, 주사전자 현미경 사진을 통해 분석한 결과 레이저를 이용한 6군에서 표면이 가장 거칠었으며 불규칙한 요철구조가 형성되었다. 이산화탄소 레이저를 이용한 표면처리 방법은 브라켓 접착시 적절한 결합강도를 제공하므로, 시효된 레진 수복물에 교정용 브라켓을 접착하기 위한 유용한 방법이 될 수 있다.

도재의 두께가 하부금속과의 전단결합강도에 미치는 영향 (The Effect of Thickness of Porcelain on Shear Bond Strength Between Heat-Pressed Porcelain and Non-Precious Metal)

  • 조정민;이청희;이규복;조진현
    • 구강회복응용과학지
    • /
    • 제28권3호
    • /
    • pp.223-232
    • /
    • 2012
  • 이번 연구는 금속 내관에 축성된 도재의 두께가 도재의 전단 결합 강도에 어떠한 영향을 주는지 알아보기 위하여 장석계 도재와 열가압 성형 도재를 다양한 두께로 축성하여 비교하였다. 120개의 금속 정육면체($4{\times}4{\times}4mm$)를 주조하여 제작한 후, 60개는 장석계 도재를, 나머지 60개는 열가압 성형 도재를 각각 1mm, 1.5mm, 2mm, 2.5mm, 3mm 그리고 3.5mm 두께로 축성하여 시편을 제작하였다. 전단 결합 강도 측정을 위해 Instron univeral testing machine에서 측정하여 비교하여 다음과 같은 결과를 얻었다. 1) 장석계 도재에서는 도재 두께가 두꺼워지면서 전단 결합 강도가 낮아지는 것으로 나왔으며, 1mm 도재 두께에서 전단 결합강도가 유의하게 높게 나왔다. 2) 열가압 성형 도재에서 도재 두께에 따른 전단 결합 강도에는 유의한 차이가 없었다. 3) 같은 두께의 장석계 도재와 열가압 성형 도재의 전단 결합강도 비교에서 장석계 도재가 높은 전단 결합강도를 나타냈으며, 두께가 1mm와 3mm일 때 유의하게 높게 나타났다. 4) 금속과 도재 사이 파절 양상은 대부분의 시편에서 금속면과 도재면이 함께 관찰되는 cohesive failure와 adhesive failure가 혼재된 양상으로 나타났으며, 도재의 두께가 증가함에 따라 금속 노출면이 감소하였다.

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

지르코니아의 새로운 표면처리 방법이 레진 시멘트와의 전단결합강도에 미치는 영향 (Effect of the New Surface Treatment Method of Zirconia on the Shear Bond Strength with Resin Cement)

  • 조원탁;배지현;최재원
    • 디지털융복합연구
    • /
    • 제19권3호
    • /
    • pp.245-251
    • /
    • 2021
  • 본 연구에서는 지르코니아의 새로운 표면처리 방법이 레진 시멘트와의 전단결합강도에 미치는 영향을 알아보고자 하였다. 지르코니아 표면처리 방법 따라 5개의 그룹으로 분류하였다: 표면처리 미시행한 군(CON군), 100℃에서 9% 불산에 10분간 노출시킨 군(HF군), 15% 지르코니아 슬러리를 적용한 군(ZS15군), 30% 지르코니아 슬러리를 적용한 군(ZS30군), 50% 지르코니아 슬러리를 적용한 군(ZS50군). 표면처리한 지르코니아 위에 레진 시멘트를 적용하였고, 열 순환 처리 후 지르코니아와 레진 시멘트 간의 전단결합강도를 측정하였다. 전단결합강도에 대한 통계 방법으로 Kruskal-Wallis test와 Mann-Whitney U test 및 Boneferroni correction를 사용하였다(α=.05/10=.005). 지르코니아 슬러리를 적용한 군은 CON군과 HF군에 비해 높은 전단결합강도를 보였다(p<.05/10=.005). 지르코니아 슬러리를 이용한 표면처리 방법은 레진 시멘트와 지르코니아 간의 전단결합강도를 증대시킴을 확인하였다. 본 연구 결과, 새로운 표면처리 방법은 지르코니아가 지닌 접착의 한계점을 보완하고 개선함으로써 지르코니아의 보다 다양한 임상적 적용 가능성을 기대할 수 있을 것으로 사료된다.

의치 수리용 레진의 색안정성과 결합강도에 관한 연구 (A STUDY ON THE COLOR STABILITY AND SHEAR BOND STRENGTH OF DENTURE REPAIR RESINS)

  • 진태호
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.24-31
    • /
    • 1995
  • This study was performed to investigate the color stability and shear bond strength of denture repair resins. The denture base resins used in this study were Premium Super-20(Lang Dental Mfg. Co., Inc.,.U.S.A.) as heat curing resin, Triad VLC Denture Base(Dentsply/York Division, U.S.A.), Triad Reline Material(Dentsply/York Division, U.S.A.), Repair Acrylic(Lang Dental Mfg. Co., Inc.,. U.S.A.), Toughron Rebase (MikiChemical Product, Kyoto, Japan), and Tokuso Rebase(Tokuyama Soda Co., Ltd., Japan) as denture repair resin. After fabrication of specimens, they stored for 20 months, then color changes and shear bond strength were measured by colorimeter(Model TC-6FX, Tokyo Denshoku Co.) and Instron Universial Test Machine. The results were as follows : 1. There were changes of $L^{\ast},\;a^{\ast},\;b^{\ast}$ and $DE^{\ast}$ in Triad VLC Denture Base after 20 months. 2. There were changes of $a^{\ast}$ in Toughron Rebase and Tokuso Rebase, and $b^{\ast}$ in Tokuso Rebase after 20 months. 3. The shear bond strength of Repair Acrylic and Toughron Rebase were higher than that of Tokuso Rebase and Triad Reline Material.

  • PDF

Smear layer 제거와 금속 이온 처리가 광중합형 글라스아이오노머와 상아질간의 결합강도에 미치는 영향 (Effect of various cleaners and mordants to bond strength of light curing glass ionomer cements to dentin)

  • 이원섭;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.45-63
    • /
    • 1994
  • 128 freshly extracted human molars were used to study the interaction between dentinal smear layer removal with various agents, and the shear bond strength of a light cured glass ionomer cement to dentin. It was proposed that the removal of smear layers using acidic cleaners followed by incorporation of Fe mordant with dentin could enhanced the infiltration of monomer component in light curing glass ionomer cement and resulted in a high bond strength. For the first treatment process for removal of smear layers on the surfaces of dentin, 50 % citric acid, 10% maleic acid and 10 % phosphoric acid were used, and for the second treatment process, 15% ferric chloride, 6.8% ferric oxalate or 30% potassium oxalate were used. Distilled water was used as a control. After double sequential treatment on dentin, a light curing glass ionomer cement was bonded to dentin. After being immersed in water at 31'C for 24 hours, shear bond strengths were measured Instron testing machine(Model No.4202, USA). Surface changes were also observed using SEM (Hitachi, S-2300, Japan) after treatment process with each agents. The following conclusions were drawn : 1. Dentin surface cleaned with maleic acid and treated with ferric oxalate showed the highest bond strength with light curing glass ionomer cement. 2. Bond strengths of glass ionomer cement to dentin treated with maleic acid or citric acid were the highest, and that treated with phosphoric acid showed the lowest. 3. The effect of ferric oxalate on shear bond strength to dentin was always higher than that of ferric chloride. 4. The smear layers were clearly removed and the orifices of dentinal tubules were opened widely by the citric acid, maleic acid and phosphoric acid. 5. The orifices of dentinal tubules opened after using the first solution were closed with the treatment of ferric chloride. 6. The precipitate like crystals were formed on dentin surfaces and tubules, but a significant decrease in bond strength of glass ionomer cement to dentin surface treated with potassium oxalate.

  • PDF