• 제목/요약/키워드: bond deterioration

검색결과 78건 처리시간 0.022초

Effects of Si cluster incorporation on properties of microcrystalline silicon thin films

  • Kim, Yeonwon;Yang, Jeonghyeon;Kang, Jun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.181-181
    • /
    • 2016
  • Hydrogenated microcrystalline silicon (${\mu}c-Si:H$) films have attracted much attention as materials of the bottom-cells in Si thin film tandem photovoltaics due to their low bandgap and excellent stability against light soaking. However, in PECVD, the source gas $SiH_4$ must be highly diluted by $H_2$, which eventually results in low deposition rate. Moreover, it is known that high-rate ${\mu}c-Si:H$ growth is usually accompanied by a large number of dangling-bond (DB) defects in the resulting films, which act as recombination centers for photoexcited carriers, leading to a deterioration in the device performance. During film deposition, Si nanoparticles generated in $SiH_4$ discharges can be incorporated into films, and such incorporation may have effects on film properties depending on the size, structure, and volume fraction of nanoparticles incorporated into films. Here we report experimental results on the effects of nonoparticles incorporation at the different substrate temperature studied using a multi-hollow discharge plasma CVD method in which such incorporation can be significantly suppressed in upstream region by setting the gas flow velocity high enough to drive nanoparticles toward the downstream region. All experiments were performed with the multi-hollow discharge plasma CVD reactor at RT, 100, and $250^{\circ}C$, respectively. The gas flow rate ratio of $SiH_4$ to $H_2$ was 0.997. The total gas pressure P was kept at 2 Torr. The discharge frequency and power were 60 MHz, 180 W, respectively. Crystallinity Xc of resulting films was evaluated using Raman spectra. The defect densities of the films were measured with electron spin resonance (ESR). The defect density of fims deposited in the downstream region (with nonoparticles) is higher defect density than that in the upstream region (without nanoparticles) at low substrate temperature of RT and $100^{\circ}C$. This result indicates that nanoparticle incorporation can change considerably their film properties depending on the substrate temperature.

  • PDF

화학적 침식에 의한 숏크리트의 열화특성 분석 - 단기거동 (Deterioration Characteristic of Shotcrete Immersed in Chemical Solution)

  • 이규필;김동규;배규진;신휴성
    • 한국터널지하공간학회 논문집
    • /
    • 제7권2호
    • /
    • pp.143-152
    • /
    • 2005
  • 숏크리트는 터널구조물 공용중 지하수 환경에 지속적으로 접촉하게 되며, 지히수에는 지역적 특성에 따라 상이하나 시멘트의 열화를 유발하는 유해성분을 함유하고 있다. 이러한 유해성분은 터널구조물 장기 공용시 숏크리트의 강도, 부착, 휨인성 등과 같은 숏크리트의 지보능력과 관계된 역학적 특성 저하 등과 같은 성능저하를 유발하게 되며, 이는 터널구조물의 안전성 저하는 물론 인명 및 경제적 피해를 야기할 수 있다. 따라서 본 연구에서는 지하수내 숏크리트의 열화 촉진인자를 조사 분석하였으며, 각 영향인자의 화학적 침식조건에 대하여 재령별로 숏크리트의 일축압축강도, 암석과 숏크리트의 부착력 등과 같은 실내시험과 X선 회절분석, SEM 및 EDS 분석 등과 같은 기기분석을 통하여 숏크리트의 내구성 및 열화특성을 분석하였다.

  • PDF

자동차 전장품용 무연솔더 접합부의 시리즈 시험 유효성 (Validation of sequence test method of Pb-free solder joint for automotive electronics)

  • 김아영;오철민;홍원식
    • Journal of Welding and Joining
    • /
    • 제33권3호
    • /
    • pp.25-31
    • /
    • 2015
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from electronic devices and system. Specifically, reliability issue of lead-free solder joint have an increasing demand for the car electronics caused by ELV banning. The authors prepared engine control unit and cabin electronics soldered with Sn-3.0Ag-0.5Cu (SAC305). To compare with the degradation characteristics of solder joint strength, thermal cycling test (TC), power-thermal cycling test (PTC) and series tests were conducted. Series tests were conducted for TC and PTC combined stress test using the same sample in sequence and continuously. TC test was performed at $-40{\sim}125^{\circ}C$ and soak time 10 min for 1000 cycles. PTC test was applied by pulse power and full function conditions during 100 cycles. Combined stress test was tested in accordance with automotive company standard. Solder joint degradation was observed by optical microscopy and environment scanning electron microscopy (ESEM). In addition, to compare with deterioration of bond strength of quad flat package (QFP) and chip components, we have measured lead pull and shear strength. Based on the series test results, consequently, we have validated of series test method for lifetime and reliability of Pb-free solder joint in automotive electronics.

고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구 (A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid)

  • 이종석;김영삼;신홍철;김영근;강충모
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.153-159
    • /
    • 2014
  • 본 연구에서는 고경질 도막재로 PET 필름을 접합하는 시공방법에 있어서 PET 필름의 표면처리 조건 및 겹침이음 길이에 따른 접합특성 및 내구특성을 검토하였는데, 그 결과 무처리 보다 코로나 방전 처리에 의해 접촉각, 접합 인장강도, 벗김저항성이 개선되었다. 특히 시험체 E (코로나 방전+프라이머+강접접착제+폴리에스터 부직포)에서 가장 높은 것으로 나타났으며, 특히 겹침 이음길이 15mm 이상일 때 16주간 장기간 열화처리에도 안정적인 접합성능을 확보하는 것으로 나타나 방수재료로서 수밀성을 확보할 것으로 판단된다.

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

경량골재를 사용한 알칼리 활성 슬래그 콘크리트의 역학적 특성 (Mechanical Properties of Alkali-Activated Slag-Based Concrete Using Lightweight Aggregates)

  • 양근혁;오승진;송진규
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.405-412
    • /
    • 2008
  • 친환경 콘크리트 개발의 의미와 한계를 파악하기 위해 알칼리 활성 경량콘크리트 6배합이 실험되었다. 무시멘트 친환경 결합재를 생산하기 위해 고로슬래그와 분말형 규산나트륨이 각각 모재와 활성화제로 이용되었다. 최대직경 13 mm의 경량골재가 굵은골재로 이용되었으며, 최대직경 5 mm의 경량골재가 천연모래의 용적비로 0, 15, 30, 50, 75 및 100% 치환되었다. 굳지 않은 콘크리트에서는 시간경과에 따른 슬럼프 변화가 측정되었으며, 굳은 콘크리트에서는 재령에 따른 압축강도 발현속도, 할렬인장강도, 파괴계수, 탄성계수, 응력-변형률 관계, 부착강도 및 건조수축 변형률이 측정되었다. 실험된 알칼리 활성 경량콘크리트의 압축강도는 경량 잔골재 치환율이 30% 이상일 때 급격히 감소하였다. 특히 사용된 경량골재의 불연속 입도분포는 콘크리트의 역학적 특성들을 나쁘게 만들었다. 알칼리 활성 경량콘크리트의 역학적 특성들은 보통포틀랜드시멘트 경량콘크리트를 위해 제시된 ACI 318-05 및 EC 2 설계기준 또는 Slate 등의 제안모델들과 비교되었다. 또한 측정된 응력-변형률 관계는 보통포틀랜드시멘트 경량콘크리트의 실험 결과에 근거하여 제시된 Tasnimi의 모델과 비교되었다. 실험 결과와 각 제안 모델들과의 비교는 잘 일치하지 않았다.

콜드조인트 발생시간이 초고강도 섬유보강 시멘트 복합체의 전단 접착 성능에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Period of Cold Joint Occurrence Effecting Shear Bond Performances of UHSCC)

  • 김민성;양현민;이한승;조근희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.25-32
    • /
    • 2016
  • 본 연구는 고강도 섬유보강 시멘트 복합체(UHSCC) 접착성능을 평가하는 것이 목적이다. Direct shear test를 통해 압축전단접착강도를 측정한 결과 NC(보통강도콘크리트)+NC 실험체($150{\times}150{\times}150mm$)에서는 모든 수준에서 유사한 압축전당접착강도를 나타내었고, 반면 UHSCC+UHSCC에서는 지연타설 30분 후부터 0분에 비해 압축전단접착강도가 낮아지는 것을 확인할 수 있었다. 이를 통한 접착면의 파괴모드를 분석한 결과 NC+NC 에서는 모든 수준에서 비계면 파괴를 보였고 UHSCC+UHSCC에서는 30분, 60분, 90분 시험체에서 계면파괴가 일어났다. NC 및 UHSCC의 타설면을 XRD 시험을 통해 분석한 결과 NC 시험체에 비해 UHSCC의 시험체 에서 많은량의 $SiO_2$의 성분이 검출되는 것을 알 수 있었고 UHSCC에서 나타난 코팅막의 주성분의 대부분은 $SiO_2$로 사료된다. 따라서 본 연구에서 사용된 UHSCC는 지연타설 30분 후 부터는 접착성능의 저하로 구조체로서의 사용이 어렵다고 판단된다. 금후 연구에서는 콜드조인트 발생 부위의 면처리 방법을 통한 접착성능 향상이 필요하다고 사료된다.

타이타늄의 표면개질에 따른 도재 결합 특성 (THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION)

  • 최택휴;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.