• Title/Summary/Keyword: bolted joint

Search Result 157, Processing Time 0.028 seconds

Strengthening of bolted shear joints in industrialized ferrocement construction

  • Ismail, M.;Shariati, M.;Abdul Awal, A.S.M.;Chiong, C.E.;Chahnasir, E. Sadeghipour;Porbar, A.;Heydari, A.;Khorami, M.
    • Steel and Composite Structures
    • /
    • v.28 no.6
    • /
    • pp.681-690
    • /
    • 2018
  • This paper highlights results of some experimental work that deals with strengthening of bolted shear joints in thin-walled ferrocement structure where steel wires, bent into U-shape are considered as simple inserts around the bolt hole. The parameters investigated include the number of layers of wire mesh, edge distance of bolt hole, size and location of the inserts. Test results have shown that for small edge distance, failure occurred either in cleavage or shearing mode, and the strength of the joint increased with an increase in the edge distance. This continued up to an upper limit set by either tension or bearing failure. The experimental study further revealed that for a given edge distance the strength of a joint can significantly be enhanced by using U-inserts. The equations developed for predicting joint strength in ferrocement composites can also be modified to include the effects of the inserts with a good level of accuracy.

Prediction of the Dynamic Characteristics of a Bolt-Joint Plates According to Bolting Conditions (볼트 체결 조건에 따른 두 판재의 동적 특성 예측)

  • Hong Sang-joon;Lee DongJin;Yoo Jeonghoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.9 s.240
    • /
    • pp.1175-1182
    • /
    • 2005
  • General systems have many substructures assembled at joints. The bolted joint is generally used in assembling the mechanical parts. However, there are no effective modeling methods to analyze the dynamic characteristics of bolt jointed structure using the finite element (FE) analysis, especially in case of large area contact. Moreover, the design methods for the appropriate bolt locations and the number of bolts considering the dynamic characteristics are not guided properly. In this study, a proper modeling method is developed to simulate the dynamic characteristics of a structure with the large interfaced area using the cone frusta method and spring elements. The natural frequencies are also controlled by adjusting the bolt-joint location and the number of bolts considering relative distances in mode shapes at the interface of bolt-jointed plates. The Modeling method and the optimized design method are verified based on the experimental and the FE analysis results.

A Fundamental Study on the Fatigue Behavior in the Joints of Steel Members (강부재(鋼部材) 이음부(部)의 피로거동(疲勞擧動)에 관(關)한 기초적(基礎的) 연구(硏究))

  • Lee, Yong Jae;Chung, Yeong Wha
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.21-28
    • /
    • 1989
  • For the study of the fatigue behavior, high-strength bolted connections on a small scale were manufactured, and carried on fatigue tests. Its experimental values were analysed by stress-fatigue life (S-N) curve. Three types of specimens : the base metal, the cireular hole and the welded sperimens had same net section were made. Through the same tests those experimental values were compared with those of the high-strength bolted conneetions. The results of these studies are as followings. It was found that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the high-strength bolted conneetions were much more about 14% and 16% than that of the base metal specimen. It was thought that this trend was due to frictional force increasing fatigue strength. It was known that fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the welded joints were less 29% and 21% than that of base metal specimen. It was thought that that trend was due to weld flaw. It was appeared that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the high-strength bolted connections were much more about 38% and 30% than that of welded joint. It was thought that it was due to both frictional force increasing the fatigue strength in bolted connections and weld flaw decreasing the fatigue strength in welded connections. It was found that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the B3 specimens were much more 2% and -2% than that of the B4 specimen. It was thought that that trend was due to the frictional force, which concerned with shape of specimen. It was known that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the specimen with circular hole was less 61% and 65% than that of base metal. It was known that the allowable stress for bolted joint was higher than that of welded Joints. If that research is continued and more data are accumulated it can be expected that a basic pattern to provided the indicator of the fatigue design of the bolted connections of steel structures and persume the safety and lifeproof of existing structures is given.

  • PDF

Dynamic Characteristics of Bolted Joint in Tube Line by External Vibration (외부 가진을 받는 관로계에서 볼트 결합부의 동특성)

  • Park, T.W.;Kim, Y.K.;Shin, G.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.4
    • /
    • pp.38-43
    • /
    • 2001
  • This paper describes the effect of dynamic characteristics in tube line by external vibration conveying fluid with the power steering system. By the experimental analysis we found out that the factor of system vibration is the fluid-structure interaction of tube line. In fluid-filled tube system we study on the influence that the natural frequency of system and the frequency of wave motion produce upon through experiment. Experiments are modal test, frequency response function in continuous system, and vibrating tests when the system is driving with bolted clamping joint condition. From the results of the experimental studies, we obtained that the natural frequencies of system are very important than the wave induced vibrations. And we found that the tendency of system vibration level was decreased by bolting force, bolting condition and clamping distance.

  • PDF

A new design method for site-joints of the tower crane mast by non-linear FEM analysis

  • Ushio, Yoshitaka;Saruwatari, Tomoharu;Nagano, Yasuyuki
    • Advances in Computational Design
    • /
    • v.4 no.4
    • /
    • pp.343-365
    • /
    • 2019
  • Among the themes related to earthquake countermeasures at construction sites, those for tower cranes are particularly important. An accident involving the collapse of a crane during the construction of a skyscraper has serious consequences, such as human injury or death, enormous repair costs, and significant delays in construction. One of the causes of deadly tower crane collapses is the destruction of the site joints of the tower crane mast. This paper proposes a new design method by static elastoplastic finite element analysis using a supercomputer for the design of the end plate-type tensile bolted joints, which are generally applied to the site joints of a tower crane mast. This new design method not only enables highly accurate and reliable joint design but also allows for a design that considers construction conditions, such as the introduction of a pre-tension axial force on the bolts. By applying this new design method, the earthquake resistance of tower cranes will undoubtedly be improved.

Corroded and loosened bolt detection of steel bolted joints based on improved you only look once network and line segment detector

  • Youhao Ni;Jianxiao Mao;Hao Wang;Yuguang Fu;Zhuo Xi
    • Smart Structures and Systems
    • /
    • v.32 no.1
    • /
    • pp.23-35
    • /
    • 2023
  • Steel bolted joint is an important part of steel structure, and its damage directly affects the bearing capacity and durability of steel structure. Currently, the existing research mainly focuses on the identification of corroded bolts and corroded bolts respectively, and there are few studies on multiple states. A detection framework of corroded and loosened bolts is proposed in this study, and the innovations can be summarized as follows: (i) Vision Transformer (ViT) is introduced to replace the third and fourth C3 module of you-only-look-once version 5s (YOLOv5s) algorithm, which increases the attention weights of feature channels and the feature extraction capability. (ii) Three states of the steel bolts are considered, including corroded bolt, bolt missing and clean bolt. (iii) Line segment detector (LSD) is introduced for bolt rotation angle calculation, which realizes bolt looseness detection. The improved YOLOv5s model was validated on the dataset, and the mean average precision (mAP) was increased from 0.902 to 0.952. In terms of a lab-scale joint, the performance of the LSD algorithm and the Hough transform was compared from different perspective angles. The error value of bolt loosening angle of the LSD algorithm is controlled within 1.09%, less than 8.91% of the Hough transform. Furthermore, the proposed framework was applied to fullscale joints of a steel bridge in China. Synthetic images of loosened bolts were successfully identified and the multiple states were well detected. Therefore, the proposed framework can be alternative of monitoring steel bolted joints for management department.

Simplified criteria for finite element modelling of European preloadable bolts

  • D'Aniello, Mario;Cassiano, David;Landolfo, Raffaele
    • Steel and Composite Structures
    • /
    • v.24 no.6
    • /
    • pp.643-658
    • /
    • 2017
  • High strength preloadable bolt assemblies are commonly adopted in beam-to-column bolted connections. Nowadays, two systems of high strength preloadable grade 10.9 bolt assembly are recommended in Europe for structural applications, namely HR and HV, which are characterized by different failure modes. Recently, experimental tests performed on HR and HV bolt assemblies highlighted that the type of bolt assembly may significantly influence the joint response. Therefore, the accuracy of numerical modelling of bolt assemblies is crucial to simulate effectively the non-linear behaviour of bolted joints with either failure mode 2 or mode 3 of the bolt rows. In light of these considerations, this present paper describes and discusses some modelling criteria for both HR and HV bolts to be implemented in 3D finite element models by finite element analysis and structural designers. The comparison between the calibrated models and experimental results shows the accuracy of the proposed assumptions in simulating all stages of assembly tensile response.

Progressive Filure Analysis of Composite Double Bolted Joints using Gradual Degradation Model (점진적 강성 저하 모델을 이용한 복합재 이중 볼트 체결부의 점진적 파손 해석 연구)

  • Kim, Pyunghwa;Kim, Sungmin;Doh, Sungchul;Yoon, Donghyun;Park, Jungsun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.26-35
    • /
    • 2019
  • In this paper, progressive failure analysis is performed on composite joints widely used in various industries such as the aerospace industry. The analysis was conducted on single bolted joints to confirm its reliability and in succession on double-bolted composite joints as well to study the characteristics of progressive failure. Hashin failure criteria and EGDM (energy based gradual degradation model) were used for the analysis. Failure variables are defined by four failure modes, respectively. According to the variables, stiffness degradation has been calculated. As a result of comparing the test and analysis results of single-bolted joints, the error was below 5% and it showed that the analytical results are rather credible. Also, the parametric analysis consequences were obtained conducting the process-progressive failure analysis on the double-bolted composite joints considering edge-distance ratio (e/d ratio) and bolt spacing.

An Experimental Study for the Strength Evaluation of Bolted Connection in Resin Transfer Molding Fiber Reinforced Polymeric Plastic (사출성형 섬유강화플라스틱 볼트 연결부의 강도 평가를 위한 실험적 연구)

  • Choi, Jinwoo;Kim, Sunhee
    • Journal of Urban Science
    • /
    • v.11 no.2
    • /
    • pp.25-30
    • /
    • 2022
  • Resin Transfer Molding FRP (RTM FRP) is a fiber reinforced polymeric plastic which is manufactured by applying pressure to fibers, injecting resin into a mold, and then impregnating it. RTM FRP is a new construction material suitable for producing non-continuum structural elements such as sole plate because it has excellent strength and can produce many members in a short time. In this study, experiments were conducted to estimate the capacity of the bolted connection of RTM FRP. First, a tensile test was conducted to confirm the mechanical properties such as the tensile strength of the RTM FRP to be used for the bolted connection experiments. In addition, experiments were conducted on the bolted connection with the thickness of the RTM FRP and the edge distance of the bolt as variables. In the first experiment, F4.8 bolts were used, and shear failure of the bolt occurred before the RTM FRPs were failed. The F4.8 bolt is a general structural bolts used for the sole plate of a bridge bearing, and it was confirmed that the RTM FRP has a higher bold bearing strength than the shear strength of a F4.8 bolt. In the second experiment, G12.9 bolts were used, and shear failure of the bolt and bearing failure of the RTM FRP occurred simultaneously. In addition, as the thickness of the RTM FRP and the edge length of the bolt increased, the strength of the joint increased. When analogized with the bearing fracture equation of steel plate, the bolted connection of RTM FRP showed a bearing strength coefficient of 0.420 to 0.549 compared to the tensile strength, and it is considered that further research is needed.