• Title/Summary/Keyword: bolted

Search Result 388, Processing Time 0.025 seconds

Study on the static and fatigue characteristics of the composite hybrid joint with uni-direction fiber orientation (일방향 복합재료 하이브리드 조인트의 정적 및 피로특성에 관한 연구)

  • Kim Byung Chul;Lim Tae Seong;Park Dong Chang;Lee Dai Gil
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.228-231
    • /
    • 2004
  • For the bolted joint of the composite structure, quasi-isotropic stacking is generally used to increase the bearing strength. For the bolted joint of uni-directional composite, the fatigue life limit of the bolted joint can be improved by applying clamping force though the static strength is still very low. In this paper, the static and fatigue characteristics of hybrid joint are investigated which can overcome the disadvantage of the bolted joint of uni-directional composite under static loading by applying adhesive joining. The experimental result shows that the static strength and fatigue life can be improved by applying clamping force to the hybrid joint and the hybrid joint is a good solution for the efficiency of the composite structures.

  • PDF

Investigation of semi-rigid bolted beam connections on prefabricated frame joints

  • Irtem, E.;Turker, K.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.4
    • /
    • pp.397-408
    • /
    • 2001
  • Bolted connections are used commonly in the precast reinforced concrete structures. In such structures, to perform structural analysis, behaviour of connections must be determined. In this study, elastic rotation stiffness of semi-rigid bolted beam connections, applied in industrial precast structures, are determined by finite element methods. The results obtained from numerical solutions are compared with an experimental study carried out for the same connections. Furthermore, stress distributions of the connection zone are determined and a reinforcement scheme is proposed. Thus, a more appropriate reinforcement arrangement for the connection zone is enabled. The connection joint of the prefabricated frame is described as rigid, hinged or elastic, and a static analysis of the frame system is performed for each case. Values of bending moments and displacements obtained from the three solutions are compared and the effects of elastic connection are discussed.

가중함수법에 의한 볼트 체결부 균열의 임계 경사각 결정에 관한 연구

  • Heo, Seong-Pil;Yang, Won-Ho;Jeong, Gi-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2344-2352
    • /
    • 2000
  • Mechanical joints such as bolted or riveted joints are widely used in mechanical components. The reliable determination of the stress intensity factors for cracks in bolted joints is needed to evaluate the safety and fatigue life of them. The weight function method is an efficient technique to calculate the stress intensity factors for various loading conditions because only the stress analysis of an uncracked model is required. In this paper the mixed-mode stress intensity factors for cracks in bolted joints are obtained by weight function method, in which the coefficients of weight function are determined by finite element analyses for reference loadings. Critical inclined angle that mode I stress intensity factor becomes maximum is determined and the effects of crack length and the magnitude of clearance on critical inclined angle are investigated.

Progressive Filure Analysis of Composite Double Bolted Joints using Gradual Degradation Model (점진적 강성 저하 모델을 이용한 복합재 이중 볼트 체결부의 점진적 파손 해석 연구)

  • Kim, Pyunghwa;Kim, Sungmin;Doh, Sungchul;Yoon, Donghyun;Park, Jungsun
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.26-35
    • /
    • 2019
  • In this paper, progressive failure analysis is performed on composite joints widely used in various industries such as the aerospace industry. The analysis was conducted on single bolted joints to confirm its reliability and in succession on double-bolted composite joints as well to study the characteristics of progressive failure. Hashin failure criteria and EGDM (energy based gradual degradation model) were used for the analysis. Failure variables are defined by four failure modes, respectively. According to the variables, stiffness degradation has been calculated. As a result of comparing the test and analysis results of single-bolted joints, the error was below 5% and it showed that the analytical results are rather credible. Also, the parametric analysis consequences were obtained conducting the process-progressive failure analysis on the double-bolted composite joints considering edge-distance ratio (e/d ratio) and bolt spacing.

An Experimental Study on Structural Behaviors of Double Shear Bolted Connections Fabricated with Ferritic Stainless Steel (STS430) (페라이트계 스테인리스강(STS430) 이면전단 볼트접합부의 구조거동에 관한 실험적 연구)

  • Kim, Tae Soo;Kim, Min Seong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.463-474
    • /
    • 2013
  • Many experimental and numerical researches for thin-walled carbon steel and austenitic stainless steel single shear bolted connections have been conducted and the modified design equations of ultimate strength were proposed. In this study, the tests of double shear bolted connections with bolt arrangements ($2{\times}1$, $2{\times}2$) and end distance parallel to the loading direction as main variables were performed. Specimens were planed with a constant dimension of edge distance perpendicular to the loading direction, bolt diameter, pitch and gauge like single shear bolted connections. The test results such as ultimate strength and fracture mode were compared with those of current design standards. Furthermore, modified block shear equations for double shear bolted connections were suggested.

A Study on Self-Healing Bolted Joints using Shape Memory Alloy (형상기억합금을 이용한 자가치유 볼트접합부 시스템에 관한 연구)

  • Chang, Ha-Joo;Lee, Chang-Gil;Park, Seung-Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.629-636
    • /
    • 2011
  • This paper describes the smart structural system that uses smart materials for real-time monitoring and active control of bolted joints in steel structures. The impedance-based structural health monitoring (SHM) techniques, which utilize the electro-mechanical coupling property of piezoelectric materials, was used to detect loose bolts in bolted joints. By monitoring the measured electrical impedance and comparing it with the measured baseline, a bolt loosening damage was detected. The damage was evaluated quantitatively using the damage metrics in conductance signature with respect to the healthy states. When loosening damage was detected in the bolted joint, the external heater actuated the shape memory alloy (SMA) washer. Then the heated SMA washer expanded axially and adjusted the bolt tension to restore the lost torque. An experiment was conducted by integrating the piezoelectric-material-based SHM function and the SMA-based active control function on a bolted joint, after which the performance of thesmart self-healing joint system was investigated.

A Study on Crack Formation in the K11 Objective Individual Combat Weapon Fire Control System using Analysis of Variance (분산분석을 활용한 K11 복합형소총 사격통제장치 균열발생 원인 연구)

  • Shin, Sang-Sik;Kim, Byeong Kyu;Sim, Chul Bo
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.289-298
    • /
    • 2015
  • Purpose: This study examined the problem of crack formation in the fire control system(FCS) of the K11 objective individual combat weapon(OCIW), using design of experiment analysis. Three hypothesis were considered. The first hypothesis is that bolted joint has an effect on impulse caused by firing the weapon and the second hypothesis is that a short time interval of shooting has an effect on impulse and lastly, the third hypothesis is that a positive correlation has between the bolted joint of the FCS and the impulse. Methods: The relationship between the bolted joint and the impulse cause by firing the weapon were examined experimentally. The first and second hypothesis was tested using correlation analysis and the t-test. Results: Using ANOVA, the first null hypothesis was rejected and the alternative hypothesis was accepted. ANONA confirmed the second null hypothesis. Correlation analysis dismissed the last null hypothesis. A positive correlation between the bolted joint and the impulse caused by shooting the weapon was verified. Conclusion: The bolted joint of the K11 FCS and the barrel of the K11 affect the impulse caused by firing the weapon. A positive correlation was established between the bolted joint of the FCS and the impulse on firing the K11 OICW.

Bending Creep of Glulam and Bolted Glulam under Changing Relative Humidity

  • PARK, Junchul;SONG, Yojin;HONG, Soonil
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.676-684
    • /
    • 2020
  • This study was carried out in order to evaluate the bending creep deflection of glulams and bolted glulams beam-to-beam connection with steel-gusset plates and bolts under changing relative humidity. The two types of glulam beams (130 mm in width, 175 mm in thickness, and 3000 mm in length) used in this study were made from domestic larch and composed of seven layers. The gussets were made of 8-mm-thick steel plates. Creep testing was conducted under constant loads in an uncontrolled environment. The test was carried out in a room that was well ventilated through a window. The creep test specimens were loaded for 33,000 hours. A bending creep test for the glulams was conducted through four-point loading. The applied stresses were 20% and 30% of the MOR in the static bending test for the glulam and bolted glulam, respectively. After 33,000 hours, the creep deflection of the glulam at a 20% stress level increased by 39% to 99%, while the creep deflection of the glulam at a 30% stress level increased by 27% to 67%, as compared with instantaneous elastic deflection. The relative creep increased during autumn and winter, and recovered during spring and summer. The relative creep of the bolted glulams was changed abruptly by loading up to 5,000 hours, but stabilized after 5,000 hours, and then gradually increased until 33,000 hours. The relative creep of the bolted glulam increased 2.11 times on average after 33,000 hours.

An Experimental Study for the Strength Evaluation of Bolted Connection in Resin Transfer Molding Fiber Reinforced Polymeric Plastic (사출성형 섬유강화플라스틱 볼트 연결부의 강도 평가를 위한 실험적 연구)

  • Choi, Jinwoo;Kim, Sunhee
    • Journal of Urban Science
    • /
    • v.11 no.2
    • /
    • pp.25-30
    • /
    • 2022
  • Resin Transfer Molding FRP (RTM FRP) is a fiber reinforced polymeric plastic which is manufactured by applying pressure to fibers, injecting resin into a mold, and then impregnating it. RTM FRP is a new construction material suitable for producing non-continuum structural elements such as sole plate because it has excellent strength and can produce many members in a short time. In this study, experiments were conducted to estimate the capacity of the bolted connection of RTM FRP. First, a tensile test was conducted to confirm the mechanical properties such as the tensile strength of the RTM FRP to be used for the bolted connection experiments. In addition, experiments were conducted on the bolted connection with the thickness of the RTM FRP and the edge distance of the bolt as variables. In the first experiment, F4.8 bolts were used, and shear failure of the bolt occurred before the RTM FRPs were failed. The F4.8 bolt is a general structural bolts used for the sole plate of a bridge bearing, and it was confirmed that the RTM FRP has a higher bold bearing strength than the shear strength of a F4.8 bolt. In the second experiment, G12.9 bolts were used, and shear failure of the bolt and bearing failure of the RTM FRP occurred simultaneously. In addition, as the thickness of the RTM FRP and the edge length of the bolt increased, the strength of the joint increased. When analogized with the bearing fracture equation of steel plate, the bolted connection of RTM FRP showed a bearing strength coefficient of 0.420 to 0.549 compared to the tensile strength, and it is considered that further research is needed.

A Fundamental Study on the Fatigue Behavior in the Joints of Steel Members (강부재(鋼部材) 이음부(部)의 피로거동(疲勞擧動)에 관(關)한 기초적(基礎的) 연구(硏究))

  • Lee, Yong Jae;Chung, Yeong Wha
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.21-28
    • /
    • 1989
  • For the study of the fatigue behavior, high-strength bolted connections on a small scale were manufactured, and carried on fatigue tests. Its experimental values were analysed by stress-fatigue life (S-N) curve. Three types of specimens : the base metal, the cireular hole and the welded sperimens had same net section were made. Through the same tests those experimental values were compared with those of the high-strength bolted conneetions. The results of these studies are as followings. It was found that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the high-strength bolted conneetions were much more about 14% and 16% than that of the base metal specimen. It was thought that this trend was due to frictional force increasing fatigue strength. It was known that fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the welded joints were less 29% and 21% than that of base metal specimen. It was thought that that trend was due to weld flaw. It was appeared that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the high-strength bolted connections were much more about 38% and 30% than that of welded joint. It was thought that it was due to both frictional force increasing the fatigue strength in bolted connections and weld flaw decreasing the fatigue strength in welded connections. It was found that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the B3 specimens were much more 2% and -2% than that of the B4 specimen. It was thought that that trend was due to the frictional force, which concerned with shape of specimen. It was known that the fatigue strength in $F_{n=100,000}$ and $F_{n=2,000,000}$ of the specimen with circular hole was less 61% and 65% than that of base metal. It was known that the allowable stress for bolted joint was higher than that of welded Joints. If that research is continued and more data are accumulated it can be expected that a basic pattern to provided the indicator of the fatigue design of the bolted connections of steel structures and persume the safety and lifeproof of existing structures is given.

  • PDF